Information to identify the model(s) to which the information relates: |
Outdoor side heat exchanger of heat pump: [select which: air/water/brine] |
Indoor side heat exchanger of heat pump: [select which: air/water/brine] |
Indication if the heater is equipped with a supplementary heater: yes/no |
If applicable: driver of compressor: [electric motor or fuel driven, gaseous or liquid fuel, internal or external combustion engine] |
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons are optional. |
Item | Symbol | Value | Unit | | Item | Symbol | Value | Unit |
---|
Rated heating capacity | Prated,h | x,x | kW | | Seasonal space heating energy efficiency | ηs,h | x,x | % |
Declared heating capacity for part load at indoor temperature 20 °C and outdoor temperature Tj | | Declared coefficient of performance or gas utilisation efficiency/auxiliary energy factor for part load at given outdoor temperatures Tj |
---|
Tj = – 7 °C | Pdh | x,x | kW | | Tj = – 7 °C | COPd or GUEh,bin/AEFh,bin | x,x | % |
Tj = + 2 °C | Pdh | x,x | kW | | Tj = + 2 °C | COPd or GUEh,bin/AEFh,bin | x,x | % |
Tj = + 7 °C | Pdh | x,x | kW | | Tj = + 7 °C | COPd or GUEh,bin/AEFh,bin | x,x | % |
Tj = + 12 °C | Pdh | x,x | kW | | Tj = + 12 °C | COPd or GUEh,bin/AEFh,bin | x,x | % |
Tbiv = bivalent temperature | Pdh | x,x | kW | | Tbiv = bivalent temperature | COPd or GUEh,bin/AEFh,bin | x,x | % |
TOL = operation limit | Pdh | x,x | kW | | TOL = operation limit | COPd or GUEh,bin/AEFh,bin | x,x | % |
For air-to-water heat pumps: Tj = – 15 °C (if TOL < – 20 °C) | Pdh | x,x | kW | | For water-to-air heat pumps: Tj = – 15 °C (if TOL < – 20 °C) | COPd or GUEh,bin/AEFh,bin | x,x | % |
Bivalent temperature | Tbiv | x | °C | | For water-to-air heat pumps: Operation limit temperature | Tol | x | °C |
| | | | | | | | |
Degradation co-efficient heat pumps | Cdh | x,x | — | | | | | |
Power consumption in modes other than "active mode" | | Supplementary heater |
---|
Off mode | POFF | x,xxx | kW | | Back-up heating capacity (*) | elbu | x,x | kW |
Thermostat-off mode | PTO | x,xxx | kW | | Type of energy input | |
Crankcase heater mode | PCK | x,xxx | kW | | Standby mode | PSB | x,xxx | kW |
Other items |
---|
Capacity control | fixed/staged/variable | | For air-to-air heat pumps: air flow rate, outdoor measured | — | x | m3/h |
Sound power level, indoor/outdoor measured | LWA | x,x/x,x | dB | | For water/brine-to-air heat pumps: Rated brine or water flow rate, outdoor side heat exchanger | — | x | m3/h |
Emissions of nitrogen oxides (if applicable) | NOx | x | mg/kWh fuel input GCV | |
GWP of the refrigerant | | | kg CO2 eq (100 years) | | | | | |
Contact details | Name and address of the manufacturer or of its authorised representative. |