Commission Regulation (EC) No 245/2009 of 18 March 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps, and repealing Directive 2000/55/EC of the European Parliament and of the Council (Text with EEA relevance)
Modified by
  • Commission Regulation (EU) No 347/2010of 21 April 2010amending Commission Regulation (EC) No 245/2009 as regards the ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps(Text with EEA relevance), 32010R0347, April 24, 2010
  • Commission Regulation (EU) 2015/1428of 25 August 2015amending Commission Regulation (EC) No 244/2009 with regard to ecodesign requirements for non-directional household lamps and Commission Regulation (EC) No 245/2009 with regard to ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps and repealing Directive 2000/55/EC of the European Parliament and of the Council and Commission Regulation (EU) No 1194/2012 with regard to ecodesign requirements for directional lamps, light emitting diode lamps and related equipment(Text with EEA relevance), 32015R1428, August 27, 2015
  • Commission Regulation (EU) 2019/2020of 1 October 2019laying down ecodesign requirements for light sources and separate control gears pursuant to Directive 2009/125/EC of the European Parliament and of the Council and repealing Commission Regulations (EC) No 244/2009, (EC) No 245/2009 and (EU) No 1194/2012(Text with EEA relevance), 32019R2020, December 5, 2019
Commission Regulation (EC) No 245/2009of 18 March 2009implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps, and repealing Directive 2000/55/EC of the European Parliament and of the Council(Text with EEA relevance)
Article 1Subject matter and scopeThis Regulation establishes ecodesign requirements for the placing on the market of fluorescent lamps without integrated ballast, of high intensity discharge lamps, and of ballasts and luminaires able to operate such lamps as defined in Article 2, even when they are integrated into other energy-using products.This Regulation also provides indicative benchmarks for products intended for use in office lighting and public street lighting.The products listed in Annex I shall be exempt from the requirements set out in this Regulation.
Article 2DefinitionsFor the purposes of this Regulation, the definitions set out in Directive 2005/32/EC shall apply. The following definitions shall also apply:1."general lighting" means substantially uniform lighting of an area without provision for special local requirements;2."office lighting" means a fixed lighting installation for office work intended to enable people to perform visual tasks efficiently and accurately;3."public street lighting" means a fixed lighting installation intended to provide good visibility to users of outdoor public traffic areas during the hours of darkness to support traffic safety, traffic flow and public security;4."discharge lamp" means a lamp in which the light is produced, directly or indirectly, by an electric discharge through a gas, a metal vapour or a mixture of several gases and vapours;5."ballast" means a device which serves mainly to limit the current of the lamp(s) to the required value in case it is connected between the supply and one or more discharge lamps. A ballast may also include means for transforming the supply voltage, dimming the lamp, correcting the power factor and, either alone or in combination with a starting device, providing the necessary conditions for starting the lamp(s);6."luminaire" means an apparatus which distributes, filters or transforms the light transmitted from one or more light sources and which includes all the parts necessary for supporting, fixing and protecting the light sources and, where necessary, circuit auxiliaries together with the means for connecting them to the supply, but not the light sources themselves;7."fluorescent lamps" means discharge lamps of the low pressure mercury type in which most of the light is emitted by one or several layers of phosphors excited by the ultraviolet radiation from the discharge;8."fluorescent lamps without integrated ballast" means single and double capped fluorescent lamps without integrated ballast;9."high intensity discharge lamps" means electric discharge lamps in which the light producing arc is stabilised by wall temperature and the arc has a bulb wall loading in excess of 3 watts per square centimetre.For the purposes of Annexes I and III to VII, the definitions set out in Annex II shall also apply.
Article 3Ecodesign requirementsThe ecodesign requirements related to fluorescent lamps without integrated ballast, to high intensity discharge lamps and to ballasts and luminaires able to operate such lamps are set out in Annex III.
Article 4Conformity assessmentThe procedure for assessing conformity referred to in Article 8 of Directive 2005/32/EC shall be the internal design control system set out in Annex IV to Directive 2005/32/EC or the management system set out in Annex V to Directive 2005/32/EC.For the purposes of conformity assessment pursuant to Article 8 of Directive 2005/32/EC, the technical documentation file shall contain a copy of the product information provided in accordance with Annex III parts 1.3, 2.2, and 3.2.
Article 5Verification procedure for market surveillance purposesSurveillance checks shall be carried out in accordance with the verification procedure set out in Annex IV.
Article 6Indicative benchmarksThe indicative benchmarks for best-performing products and technology currently available on the market are identified:(a)in Annex V for fluorescent lamps without integrated ballast, for high intensity discharge lamps and for ballasts and luminaires able to operate such lamps;(b)in Annexes VI and VII for products intended for use in office lighting or in public street lighting.
Article 7RepealDirective 2000/55/EC shall be repealed as from one year after the entry into force of this Regulation.
Article 8RevisionNo later than 5 years after the entry into force of this Regulation, the Commission shall review it in light of technological progress.
Article 9Entry into forceThis Regulation shall enter into force on the 20th day following its publication in the Official Journal of the European Union.The requirements set out in Annex III shall apply in accordance with the timetable provided for therein.
This Regulation shall be binding in its entirety and directly applicable in all Member States.ANNEX IExemptions1.The following lamps shall be exempt from the provisions of Annex III, provided that the technical documentation file drawn up for the purposes of conformity assessment pursuant to Article 8 of Directive 2009/125/EC states which of the technical parameters listed hereunder provide(s) a basis for their exemption:(a)lamps that are not white light sources as defined in Annex II; this exemption does not apply to high pressure sodium lamps;(b)lamps that are directional light sources as defined in Annex II;(c)blended high intensity discharge lamps having:6 % or more of total radiation of the range 250-780 nm in the range of 250-400 nm; and11 % or more of total radiation of the range 250-780 nm in the range of 630-780 nm; and5 % or more of total radiation of the range 250-780 nm in the range of 640-700 nm;(d)blended high intensity discharge lamps having:the peak of the radiation between 315-400 nm (UVA) or 280-315 nm (UVB);(e)double capped fluorescent lamps having:a diameter of 7 mm (T2) and less,a diameter of 16 mm (T5) and lamp power P ≤ 13 W or P > 80 W,a diameter of 38 mm (T12), lamp cap G-13 Medium BiPin base, +/– 5 m (+magenta, –green) colour compensating filter value limit (cc). CIE coordinates x=0,330 y=0,335 and x=0,415 y=0,377, anda diameter of 38 mm (T12) and equipped with an external ignition strip;(f)single capped fluorescent lamps having a diameter of 16 mm (T5) 2G11 4 pin base, Tc = 3200 K with chromaticity coordinates x=0,415 y=0,377 and Tc = 5500 K with chromaticity coordinates x=0,330 y=0,335;(g)high intensity discharge lamps with Tc > 7000 K;(h)high intensity discharge lamps having a specific effective UV output > 2 mW/klm; and(i)high intensity discharge lamps not having lamp cap E27, E40, PGZ12.2.The following products shall be exempt from the provisions of Annex III, provided that in all forms of product information it is stated that they are not intended for general lighting use within the meaning of this Regulation, or that they are intended for use in applications listed in points (b) to (e):(a)products intended for use in applications other than general lighting and products incorporated into products which do not provide a general lighting function;(b)lamps covered by the requirements of Directives 94/9/EC of the European Parliament and of the CouncilOJ L 100, 19.4.1994, p. 1. or Directive 1999/92/EC of the European Parliament and of the CouncilOJ L 23, 28.1.2000, p. 57.;(c)emergency lighting luminaires and emergency sign luminaires within the meaning of Directive 2006/95/EC of the European Parliament and of the CouncilOJ L 374, 27.12.2006, p. 10..(d)ballasts intended for use in luminaires defined in paragraph (c) and designed to operate lamps in emergency conditions;(e)luminaires covered by the requirements of Directive 94/9/EC, Directive 1999/92/EC, Directive 2006/42/EC of the European Parliament and of the CouncilOJ L 157, 9.6.2006, p. 24., Council Directive 93/42/EECOJ L 169, 12.7.1993, p. 1., Council Directive 88/378/EECOL L 187, 16.7.1988, p. 1. and luminaires integrated into equipment covered by these requirements.The intended purpose shall be stated for each product in the product information, and the technical documentation file drawn up for the purposes of conformity assessment pursuant to Article 8 of Directive 2009/125/EC shall list the technical parameters that make the product design specific for the stated intended purpose.ANNEX IITechnical parameters covered and definitions for the purposes of Annexes I and III to VII1.Technical parameters for ecodesign requirementsFor the purposes of compliance and verification of compliance with the requirements of this Regulation, the parameters below shall be established by reliable, accurate and reproducible measurement procedures, which take into account the generally recognised state of the art measurement methods.(a)"Luminous efficacy of a source", "light source efficacy" or "lamp efficacy" (ηsource), which means the quotient of the luminous flux emitted (Ф) by the power consumed by the source (Psource). ηsource = Ф / Psource. Unit: lm/W. The power dissipated by auxiliary equipment such as ballasts is not included in the power consumed by the source.(b)"Lamp Lumen Maintenance Factor" (LLMF), which means the ratio of the luminous flux emitted by the lamp at a given time in its life to the initial luminous flux.(c)"Lamp Survival Factor" (LSF), which means the fraction of the total number of lamps which continue to operate at a given time under defined conditions and switching frequency.For the purposes of Table 6 in Annex III, the LSF shall be measured in high frequency operating mode with a switching cycle of 11h/1h.(d)"Ballast efficiency" (ηballast), which means the ratio between the lamp power (ballast output) and the input power of the lamp-ballast circuit with possible sensors, network connections and other auxiliary loads disconnected.(e)"Chromaticity", which means the property of a colour stimulus defined by its chromaticity coordinates, or by its dominant or complementary wavelength and purity taken together.(f)"Luminous flux", which means a quantity derived from radiant flux (radiant power) by evaluating the radiation according to the spectral sensitivity of the human eye.(g)"Correlated Colour Temperature" (Tc [K]), which means temperature of a Planckian (black body) radiator whose perceived colour most closely resembles that of a given stimulus at the same brightness and under specified viewing conditions.(h)"Colour rendering" (Ra), which means the effect of an illuminant on the colour appearance of objects by conscious or subconscious comparison with their colour appearance under a reference illuminant.(i)"Specific effective radiant UV power", which means the effective power of the UV radiation of a lamp related to its luminous flux (unit: mW/klm).(j)"Ingress protection grading", which means a coding system to indicate the degree of protection provided by an enclosure against ingress of dust, solid objects and moisture and to give additional information in connection with such protection.2.Technical parameters for indicative benchmarks(a)"Lamp mercury content", which means the amount of mercury contained in the lamp.(b)"Luminaire Maintenance Factor" (LMF), which means the ratio of the light output ratio of a luminaire at a given time to the initial light output ratio.(c)"Utilisation Factor" (UF) of an installation for a reference surface, which means the ratio of the luminous flux received by the reference surface to the sum of the individual total fluxes of the lamps of the installation.3.Definitions(a)"Directional Light Source" (DLS) means light sources having at least 80 % light output within a solid angle of π sr (corresponding to a cone with angle of 120 °).(b)"White light source" means a light source having chromaticity coordinates that satisfy the following requirement:0,270 < x < 0,530– 2,3172 x2 + 2,3653 x – 0,2199 < y < – 2,3172 x2 + 2,3653 x – 0,1595(c)A "rated" value means a quantity value for a characteristic of a product for operating conditions specified in this Regulation or in applicable standards. Unless stated otherwise, all product parameter limits are expressed in rated values.(d)A "nominal" value means an approximate quantity value used to designate or identify a product.(e)"Light pollution" means the sum of all adverse impacts of artificial light on the environment, including the impact of obtrusive light.(f)"Obtrusive light" means the part of the light from a lighting installation that does not serve the purpose for which the installation was designed. It includes:light improperly falling outside the area to be lit,diffused light in the neighbourhood of the lighting installation,sky glow, which is the brightening of the night sky that results from the direct and indirect reflection of radiation (visible and non-visible), scattered from the constituents of the atmosphere (gas molecules, aerosols and particulate matter) in the direction of observation.(g)"Efficiency Base ballast" (EBb) means the relationship between the rated lamp power (Plamp) and the ballast efficiency.For ballasts for single and double capped fluorescent lamps, the EBbFL is calculated as follows:When Plamp ≤ 5 W : EBbFL = 0,71When 5 W < Plamp < 100 W : EBbFL = Plamp/(2*sqrt(Plamp/36)+38/36*Plamp +1)When Plamp ≥ 100 W : EBbFL = 0,91(h)"Second lamp envelope" means a second outer lamp envelope which is not required for the production of light, such as an external sleeve for preventing mercury and glass release into the environment in case of lamp breakage. In determining the presence of a second lamp envelope, the arc tubes of high intensity discharge lamps shall not count as a lamp envelope.(i)"Light source control gear" means one or more components between the supply and one or more light sources which may serve to transform the supply voltage, limit the current of the lamp(s) to the required value, provide starting voltage and preheating current, prevent cold starting, correct power factor or reduce radio interference. Ballasts, halogen convertors and transformers and Light Emitting Diode (LED) drivers are examples of light source control gears.(j)"High-pressure mercury (vapour) lamp" means a high intensity discharge lamp in which the major portion of light is produced, directly or indirectly, by radiation from mercury operating at a partial pressure in excess of 100 kilopascals.(k)"High-pressure sodium (vapour) lamp" means a high intensity discharge lamp in which the light is produced mainly by radiation from sodium vapour operating at a partial pressure of the order of 10 kilopascals.(l)"Metal halide lamp" means a high intensity discharge lamp in which the light is produced by radiation from a mixture of metallic vapour, metal halides and the products of the dissociation of metal halides.(m)"Electronic or high frequency ballast" means a mains supplied a.c. to a.c. invertor, including stabilising elements for starting and operating one or more tubular fluorescent lamps, generally at high frequency.(n)"Clear lamp" means a high-intensity discharge lamp with a transparent outer envelope or outer tube in which the light producing arc tube is clearly visible (e.g. clear glass lamp).(o)"Blended lamp" means a lamp containing a mercury vapour lamp and an incandescent lamp filament connected in series in the same bulb.ANNEX IIIEcodesign requirements for fluorescent and high intensity discharge lamps and ballasts and luminaires able to operate such lampsFor each ecodesign requirement, the moment from which it applies is specified below. Unless a requirement is superseded or this is otherwise specified, it shall continue to apply together with the requirements introduced at later stages.1.REQUIREMENTS FOR FLUORESCENT LAMPS WITHOUT INTEGRATED BALLAST AND FOR HIGH INTENSITY DISCHARGE LAMPS1.1.Lamp efficacy requirementsA.First stage requirementsOne year after the entry into force of this Regulation:Double capped fluorescent lamps of 16 mm and 26 mm diameter (T5 and T8 lamps) shall have at least the rated luminous efficacies as specified in Table 1 at 25 °C.Spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5) shall comply with the requirements set out in Table 5 for T9 circular lamps.
Table 1Rated minimum efficacy values for T8 and T5 lamps
T8 (26 mm Ø)T5 (16 mm Ø)High EfficiencyT5 (16 mm Ø)High Output
Nominal wattage (W)Rated luminous efficacy (lm/W), 100 h initial valueNominal wattage (W)Rated luminous efficacy (lm/W), 100 h initial valueNominal wattage (W)Rated luminous efficacy (lm/W), 100 h initial value
156314862473
187521903979
257628934988
308035945482
36938077
3887
5890
7089
Single capped fluorescent lamps shall have the following rated luminous efficacies at 25 °C.In case the nominal wattages or lamp shapes are different from those listed in tables 2 to 5: lamps must reach the luminous efficacy of the nearest equivalent in terms of wattage and shape. If the nominal wattage is at equal distance from two wattages in the table, it shall conform to the higher efficacy of the two. If the nominal wattage is higher than the highest wattage in the table, it shall conform to the efficacy of that highest wattage.
Table 2Rated minimum efficacy values for single capped fluorescent lamps working on electromagnetic and electronic ballast
Small single parallel tube, lamp cap G23 (2 pin) or 2G7 (4 pin)Double parallel tubes, lamp cap G24d (2 pin) or G24q (4 pin)Triple parallel tubes, lamp cap GX24d (2 pin) or GX24q (4 pin)
Nominal wattage(W)Rated luminous efficacy (lm/W), 100 h initial valueNominal wattage(W)Rated luminous efficacy (lm/W), 100 h initial valueNominal wattage(W)Rated luminous efficacy (lm/W), 100 h initial value
54810601362
75713691867
96718672666
11762666
4 legs in one plane, lamp cap 2G10(4 pin)Long single parallel tube, lamp cap 2G11(4 pin)
Nominal wattage(W)Rated luminous efficacy (lm/W), 100 h initial valueNominal wattage(W)Rated luminous efficacy (lm/W), 100 h initial value
18611867
24712475
36783482
3681
Table 3Rated minimum efficacy values for single capped fluorescent lamps, working only on electronic ballast
Triple parallel tubes, lamp cap GX24q(4 pin)Four parallel tubes, lamp cap GX24q(4 pin)Long single parallel tube, lamp cap 2G11(4 pin)
Nominal wattage(W)Rated luminous efficacy (lm/W), 100 h initial valueNominal wattage(W)Rated luminous efficacy (lm/W), 100 h initial valueNominal wattage(W)Rated luminous efficacy (lm/W), 100 h initial value
327557754083
427470745582
57758075
7074
Table 4Rated minimum efficacy values for single capped fluorescent lamps with square shape or (very) high output
Single flat plane tube, lamp cap GR8 (2 pin), GR10q (4 pin) or GRY10q3 (4 pin)Four or three parallel T5 tubes, lamp cap 2G8 (4 pin)
Nominal wattage (W)Rated luminous efficacy (lm/W), 100 h initial valueNominal wattage (W)Rated luminous efficacy (lm/W), 100 h initial value
10656067
16668275
21648571
287312075
3871
5571
Table 5Rated minimum efficacy values for T9 and T5 Circular lamps
T9 Circular, tube diameter 29 mm with base G10qT5 Circular, tube diameter 16 mm with base 2GX13
Nominal wattage (W)Rated luminous efficacy (lm/W), 100 h initial valueNominal wattage (W)Rated luminous efficacy (lm/W), 100 h initial value
22522277
32644078
40705575
60606080
Corrections applicable to both single and double capped fluorescent lampsThe required luminous efficacy at 25 °C may be lower than required in the tables above in the following cases:
Table 6Deduction percentages for rated minimum efficacy values for fluorescent lamps with high colour temperature and/or high colour rendering and/or second lamp envelope and/or long life
Lamp parameterDeduction from luminous efficacy at 25 °C
Tc ≥ 5000 K10 %
95 ≥ Ra > 9020 %
Ra > 9530 %
Second lamp envelope10 %
Lamp Survival Factor ≥ 0,50 after 40000 burning hours5 %
The indicated deductions are cumulative.Single and double capped fluorescent lamps that do not have their optimum temperature at 25 °C must still comply at their optimum temperature with the luminous efficacy requirements as set out in the tables above.
B.Second stage requirementsThree years after the entry into force of this Regulation, the following efficacy requirements shall apply to fluorescent lamps without integrated ballast and high-intensity discharge lamps.Double capped fluorescent lampsThe requirements applicable to double capped fluorescent lamps 26 mm in diameter (T8) during the first stage shall apply to all double capped fluorescent lamps of other diameters than those covered in the first stage.These lamps must conform to the minimum efficacy of the T8 lamp which is their nearest equivalent with regards to wattage. If the nominal wattage is higher than the highest wattage in the table, it shall conform to the efficacy of that highest wattage.The corrections (Table 6) and the specific requirements for spiral-shaped double capped fluorescent lamps defined for the first stage shall continue to apply.High-intensity discharge lampsLamps with Tc ≥ 5000 K or equipped with a second lamp envelope shall fulfil at least 90 % of the applicable lamp efficacy requirements in tables 7, 8 and 9.High Pressure Sodium lamps with Ra ≤ 60 shall have at least the rated luminous efficacies in Table 7:
Table 7Rated minimum efficacy values for high pressure sodium lamps with Ra ≤ 60
Nominal Lamp wattage [W]Rated Lamp Efficacy [lm/W] — Clear lampsRated Lamp Efficacy [lm/W] — Not clear lamps
W ≤ 45≥ 60≥ 60
45 < W ≤ 55≥ 80≥ 70
55 < W ≤ 75≥ 90≥ 80
75 < W ≤ 105≥ 100≥ 95
105 < W ≤ 155≥ 110≥ 105
155 < W ≤ 255≥ 125≥ 115
255 < W ≤ 605≥ 135≥ 130
The requirements in Table 7 shall apply to high pressure sodium retrofit lamps designed to operate on high pressure mercury vapour lamp control gear only 6 years after the entry into force of this Regulation.Metal halide lamps with Ra ≤ 80 and high pressure sodium lamps with Ra > 60 shall have at least the rated luminous efficacies in Table 8:
Table 8Rated minimum efficacy values for Metal Halide Lamps with Ra ≤ 80 and for high pressure sodium lamps with Ra > 60
Nominal Lamp Wattage [W]Rated Lamp Efficacy [lm/W] — Clear lampsRated Lamp Efficacy [lm/W] — Not clear lamps
W ≤ 55≥ 60≥ 60
55 < W ≤ 75≥ 75≥ 70
75 < W ≤ 105≥ 80≥ 75
105 < W ≤ 155≥ 80≥ 75
155 < W ≤ 255≥ 80≥ 75
255 < W ≤ 405≥ 85≥ 75
Six years after the entry into force of this Regulation, other high intensity discharge lamps shall have at least the rated luminous efficacies in Table 9:
Table 9Rated minimum efficacy values for other high intensity discharge lamps
Nominal Lamp wattage [W]Rated Lamp Efficacy [lm/W]
W ≤ 4050
40 < W ≤ 5055
50 < W ≤ 7065
70 < W ≤ 12570
125 < W75
C.Third stage requirementsEight years after the entry into force of this Regulation:Fluorescent lamps without integrated ballast shall be able to operate with ballasts of energy efficiency class A2 or more efficient ballasts in accordance with point 2.2 of Annex III. In addition they may also operate with ballasts of less efficient classes than A2.Metal halide lamps shall have at least the rated luminous efficacies in Table 10:
Table 10Rated minimum efficacy values for metal halide lamps (third stage)
Nominal Lamp wattage (W)Rated Lamp Efficacy (lm/W) — Clear lampsRated Lamp Efficacy (lm/W) — Not clear lamps
W ≤ 55≥ 70≥ 65
55 < W ≤ 75≥ 80≥ 75
75 < W ≤ 105≥ 85≥ 80
105 < W ≤ 155≥ 85≥ 80
155 < W ≤ 255≥ 85≥ 80
255 < W ≤ 405≥ 90≥ 85
Lamps equipped with Tc ≥ 5000 K or with a second lamp envelope shall fulfil at least 90 % of the applicable lamp efficacy requirements.
1.2.Lamp performance requirementsA.First stage requirementsOne year after the entry into force of this Regulation:Fluorescent lamps without integrated ballast covered by the requirements of Annex III.1.1.A shall have a colour rendering index (Ra) of at least 80.B.Second stage requirementsThree years after the entry into force of this Regulation:Fluorescent lamps without integrated ballast shall have a colour rendering index (Ra) of at least 80. They shall have at least the lamp lumen maintenance factors in Table 11:
Table 11Lamp lumen maintenance factors for single and double capped fluorescent lamps — Stage 2
Lamp lumen maintenance factorBurning hours
Lamp types20004000800016000
Double-Capped Fluorescent lamps operating on non-high frequency ballasts0,950,920,90
T8 Double-Capped Fluorescent lamps on high frequency ballast with warmstart0,960,920,910,90
Other Double-Capped Fluorescent lamps on high frequency ballast with warmstart0,950,920,900,90
Circular Single-Capped Fluorescent lamps operating on non-high frequency ballasts, T8 U-shaped double-capped fluorescent lamps and spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5)0,800,74
0,72 at 5000 burning hours
Circular Single-Capped Fluorescent lamps operating on high frequency ballasts0,850,830,80
0,75 at 12000 burning hours
Other Single-Capped Fluorescent lamps operating on non-high frequency ballasts0,850,780,75
Other Single-Capped Fluorescent lamps on high frequency ballast with warmstart0,900,840,810,78
The following cumulative deductions shall be applied to the values in Table 11:
Table 11aDeduction percentages for fluorescent lamp lumen maintenance requirements
Lamp parameterDeduction from lamp lumen maintenance requirement
Lamps with 95 ≥ Ra > 90At burning hours ≤ 8000 h: – 5 %At burning hours > 8000 h: – 10 %
Lamps with Ra > 95At burning hours ≤ 4000 h: – 10 %At burning hours > 4000 h: – 15 %
Lamps with a colour temperature ≥ 5000 K10 %
Fluorescent lamps without integrated ballast shall have at least the lamp survival factors in Table 12:
Table 12Lamp survival factors for single and double capped fluorescent lamps — Stage 2
Lamp survival factorBurning hours
Lamp types20004000800016000
Double-Capped Fluorescent lamps operating on non-high frequency ballasts0,990,970,90
Double-Capped Fluorescent lamps on high frequency ballast with warmstart0,990,970,920,90
Circular Single-Capped Fluorescent lamps operating on non-high frequency ballasts, T8 U-shaped double-capped fluorescent lamps and spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5)0,980,77
0,50 at 5000 burning hours
Circular Single-Capped Fluorescent lamps operating on high frequency ballasts0,990,970,85
0,50 at 12000 burning hours
Other Single-Capped Fluorescent lamps operating on non-high frequency ballasts0,980,900,50
Other Single-Capped Fluorescent lamps on high frequency ballast with warmstart0,990,980,88
High pressure sodium lamps with lamp efficacy requirements shall have at least the lamp lumen maintenance factors and lamp survival factors in Table 13:
Table 13Lamp lumen maintenance factors & lamp survival factors for high pressure sodium lamps — Stage 2
High pressure sodium lamp category and burning hours for measurementLamp lumen maintenance factorLamp survival factor
P ≤ 75 WLLMF and LSF measured at 12000 burning hoursRa ≤ 60> 0,80> 0,90
Ra > 60> 0,75> 0,75
all retrofit lamps designed to operate on high pressure mercury vapour lamp ballast> 0,75> 0,80
P > 75 W ≤ 605 WLLMF and LSF measured at 16000 burning hoursRa ≤ 60> 0,85> 0,90
Ra > 60> 0,70> 0,65
all retrofit lamps designed to operate on high pressure mercury vapour lamp ballast> 0,75> 0,55
The requirements in Table 13 for retrofit lamps designed to operate on high pressure mercury vapour lamp ballast shall be applicable until 6 years after the entry into force of this Regulation.
C.Third stage requirementsEight years after the entry into force of this Regulation:Metal halide lamps with lamp efficacy requirements shall have at least the lamp lumen maintenance factors and lamp survival factors in Table 14:
Table 14Lamp lumen maintenance factors and lamp survival factors for metal halide lamps — Stage 3
Burning HoursLamp lumen maintenance factorLamp survival factor
12000> 0,80> 0,80
1.3.Product information requirements on lampsOne year after the entry into force of this Regulation, manufacturers shall provide at least the following information on free-access websites and in other forms they deem appropriate for each of their fluorescent lamps without integrated ballast and each of their high intensity discharge lamps. That information shall also be contained in the technical documentation file drawn up for the purposes of conformity assessment pursuant to Article 8 of Directive 2005/32/EC.(a)Nominal and rated lamp wattage.(b)Nominal and rated lamp luminous flux.(c)Rated lamp efficacy at 100 h in standard conditions (25 °C, for T5 lamps at 35 °C). For fluorescent lamps both at 50 Hz (mains frequency) operation (where applicable) and at High Frequency (> 50 Hz) operation (where applicable) for the same rated luminous flux in all cases, indicating for High Frequency operation the calibration current of the test conditions and/or the rated voltage of the HF generator with the resistance. It shall be stated in a conspicuous manner that the power dissipated by auxiliary equipment such as ballasts is not included in the power consumed by the source.(d)Rated lamp Lumen Maintenance Factor at 2000 h, 4000 h, 6000 h, 8000 h, 12000 h, 16000 h and 20000 h (up to 8000 h only for new lamps on the market where no data is yet available), indicating which operation mode of the lamp was used for the test if both 50 Hz and High Frequency operation are possible.(e)Rated lamp Survival Factor at 2000 h, 4000 h, 6000 h, 8000 h, 12000 h, 16000 h and 20000 h (up to 8000 h only for new lamps on the market where no data is yet available), indicating which operation mode of the lamp was used for the test if both 50 Hz and High Frequency operation are possible.(f)lamp mercury content as X.X mg.(g)Colour Rendering Index (Ra) of the lamp.(h)Colour temperature of the lamp.(i)Ambient temperature inside the luminaire at which the lamp was designed to maximise its luminous flux. If this temperature is equal to or lower than 0 °C or equal to or higher than 50 °C, it shall be stated that the lamp is not suitable for indoor use at standard room temperatures.(j)For fluorescent lamps without integrated ballast, the energy efficiency index(es) of ballasts as defined in Table 17 with which the lamp can operate.
2.REQUIREMENTS ON BALLASTS FOR FLUORESCENT LAMPS WITHOUT INTEGRATED BALLAST AND BALLASTS FOR HIGH INTENSITY DISCHARGE LAMPS2.1.Ballast energy performance requirementsMultiwattage ballasts shall comply with the requirements below according to each wattage on which they operate.A.First stage requirementsOne year after this Regulation comes into force:The minimum energy efficiency index class shall be B2 for ballasts covered by table 17 in Annex III.2.2, A3 for the ballasts covered by table 18, and A1 for dimmable ballasts covered by table 19.At the dimming position corresponding to 25 % of the lumen output of the operated lamp, the input power (Pin) of the lamp-ballast circuit shall not exceed:Pin < 50 % * PLratedballastWhere PLrated is the rated lamp power and ηballast is the minimum energy efficiency limit of the respective EEI class.The power consumption of the fluorescent lamp ballasts shall not exceed 1,0 W when operated lamps do not emit any light in normal operating conditions and when other possible connected components (network connections, sensors etc.) are disconnected. If they cannot be disconnected, their power shall be measured and deducted from the result.B.Second stage requirementsThree years after the implementing measure comes into force:Ballasts for high intensity discharge lamps shall have the efficiency described in Table 15.
Table 15Minimum efficiency for ballasts for high intensity discharge lamps — Stage 2
Nominal lamp wattage (P)WMinimum ballast efficiency (ηballast)%
P ≤ 3065
30 < P ≤ 7575
75 < P ≤ 10580
105 < P ≤ 40585
P > 40590
The power consumption of ballasts used with fluorescent lamps without integrated ballast shall not exceed 0,5 W when operated lamps do not emit any light in normal operating conditions. This requirement shall apply to ballasts when other possible connected components (network connections, sensors etc.) are disconnected. If they cannot be disconnected, their power shall be measured and deducted from the result.
C.Third stage requirementsEight years after this Regulation comes into force:Ballasts for fluorescent lamps without integrated ballast shall have the efficiency:ηballast ≥ EBbFLwhere EBbFL is defined in Annex II.3.gBallasts for high intensity discharge lamps shall have the efficiency described in Table 16.
Table 16Minimum efficiency for ballasts for high intensity discharge lamps — Stage 3
Nominal lamp wattage (P)WMinimum ballast efficiency (ηballast)%
P ≤ 3078
30 < P ≤ 7585
75 < P ≤ 10587
105 < P ≤ 40590
P > 40592
2.2.Product information requirements on ballastsManufacturers of ballasts shall provide at least the following information on free-access websites and in other forms they deem appropriate for each of their ballast models. That information shall also be affixed in a distinct and durable form to the ballast. It shall also be contained in the technical documentation file drawn up for the purposes of conformity assessment pursuant to Article 8 of Directive 2005/32/EC.A.First stage requirementsOne year after the entry into force of this Regulation:for ballasts for fluorescents lamps, an energy efficiency index (EEI) class shall be provided as defined below."Energy efficiency index" (EEI) means a classification system of ballasts for fluorescent lamps without integrated ballasts in classes according to efficiency limit values. The classes for non-dimmable ballasts are (in descending order of efficiency) A2 BAT, A2, A3, B1, B2 and for dimmable ballasts A1 BAT and A1.Table 17 contains the EEI classes for ballasts which are designed to operate the lamps mentioned in the table or other lamps which are designed to be operated by the same ballasts as the lamps mentioned in the table (meaning that the data of the reference ballast is equal).
Table 17Energy efficiency index requirements for non-dimmable ballasts for fluorescent lamps
LAMP DATABALLAST EFFICIENCY (Plamp/Pinput)
Non-dimmable
Lamp typeNominal WattageILCOS CODERated/typical wattageA2 BATA2A3B1B2
50 HzHF
WWW
T815FD-15-E-G13-26/4501513,587,8 %84,4 %75,0 %67,9 %62,0 %
T818FD-18-E-G13-26/600181687,7 %84,2 %76,2 %71,3 %65,8 %
T830FD-30-E-G13-26/900302482,1 %77,4 %72,7 %79,2 %75,0 %
T836FD-36-E-G13-26/1200363291,4 %88,9 %84,2 %83,4 %79,5 %
T838FD-38-E-G13-26/105038,53287,7 %84,2 %80,0 %84,1 %80,4 %
T858FD-58-E-G13-26/1500585093,0 %90,9 %84,7 %86,1 %82,2 %
T870FD-70-E-G13-26/180069,56090,9 %88,2 %83,3 %86,3 %83,1 %
TC-L18FSD-18-E-2G11181687,7 %84,2 %76,2 %71,3 %65,8 %
TC-L24FSD-24-E-2G11242290,7 %88,0 %81,5 %76,0 %71,3 %
TC-L36FSD-36-E-2G11363291,4 %88,9 %84,2 %83,4 %79,5 %
TCF18FSS-18-E-2G10181687,7 %84,2 %76,2 %71,3 %65,8 %
TCF24FSS-24-E-2G10242290,7 %88,0 %81,5 %76,0 %71,3 %
TCF36FSS-36-E-2G10363291,4 %88,9 %84,2 %83,4 %79,5 %
TC-D / DE10FSQ-10-E-G24q=1FSQ-10-I-G24d=1109,589,4 %86,4 %73,1 %67,9 %59,4 %
TC-D / DE13FSQ-13-E-G24q=1FSQ-13-I-G24d=11312,591,7 %89,3 %78,1 %72,6 %65,0 %
TC-D / DE18FSQ-18-E-G24q=2FSQ-18-I-G24d=21816,589,8 %86,8 %78,6 %71,3 %65,8 %
TC-D / DE26FSQ-26-E-G24q=3FSQ-26-I-G24d=3262491,4 %88,9 %82,8 %77,2 %72,6 %
TC-T / TE13FSM-13-E-GX24q=1FSM-13-I-GX24d=11312,591,7 %89,3 %78,1 %72,6 %65,0 %
TC-T / TE18FSM-18-E-GX24q=2FSM-18-I-GX24d=21816,589,8 %86,8 %78,6 %71,3 %65,8 %
TC-T / TC-TE26FSM-26-E-GX24q=3FSM-26-I-GX24d=326,52491,4 %88,9 %82,8 %77,5 %73,0 %
TC-DD / DDE10FSS-10-E-GR10qFSS-10-L/P/H-GR10q10,59,586,4 %82,6 %70,4 %68,8 %60,5 %
TC-DD / DDE16FSS-16-E-GR10qFSS-16-I-GR8FSS-16-L/P/H-GR10q161587,0 %83,3 %75,0 %72,4 %66,1 %
TC-DD / DDE21FSS-21-E-GR10qFSS-21-L/P/H-GR10q2119,589,7 %86,7 %78,0 %73,9 %68,8 %
TC-DD / DDE28FSS-28-E-GR10qFSS-28-I-GR8FSS-28-L/P/H-GR10q2824,589,1 %86,0 %80,3 %78,2 %73,9 %
TC-DD / DDE38FSS-38-E-GR10qFSS-38-L/P/H-GR10q38,534,592,0 %89,6 %85,2 %84,1 %80,4 %
TC5FSD-5-I-G23FSD-5-E-2G75,4572,7 %66,7 %58,8 %49,3 %41,4 %
TC7FSD-7-I-G23FSD-7-E-2G77,16,577,6 %72,2 %65,0 %55,7 %47,8 %
TC9FSD-9-I-G23FSD-9-E-2G78,7878,0 %72,7 %66,7 %60,3 %52,6 %
TC11FSD-11-I-G23FSD-11-E-2G711,81183,0 %78,6 %73,3 %66,7 %59,6 %
T54FD-4-E-G5-16/1504,53,664,9 %58,1 %50,0 %45,0 %37,2 %
T56FD-6-E-G5-16/22565,471,3 %65,1 %58,1 %51,8 %43,8 %
T58FD-8-E-G5-16/3007,17,569,9 %63,6 %58,6 %48,9 %42,7 %
T513FD-13-E-G5-16/5251312,884,2 %80,0 %75,3 %72,6 %65,0 %
T9-C22FSC-22-E-G10q-29/200221989,4 %86,4 %79,2 %74,6 %69,7 %
T9-C32FSC-32-E-G10q-29/300323088,9 %85,7 %81,1 %80,0 %76,0 %
T9-C40FSC-40-E-G10q-29/400403289,5 %86,5 %82,1 %82,6 %79,2 %
T26FDH-6-L/P-W4,3x8,5d-7/220572,7 %66,7 %58,8 %
T28FDH-8-L/P-W4,3x8,5d-7/3207,876,5 %70,9 %65,0 %
T211FDH-11-L/P-W4,3x8,5d-7/42010,881,8 %77,1 %72,0 %
T213FDH-13-L/P-W4,3x8,5d-7/52013,384,7 %80,6 %76,0 %
T221FDH-21-L/P-W4,3x8,5d-7/2188,9 %85,7 %79,2 %
T223FDH-23-L/P-W4,3x8,5d-7/2389,8 %86,8 %80,7 %
T5-E14FDH-14-G5-L/P-16/55013,784,7 %80,6 %72,1 %
T5-E21FDH-21-G5-L/P-16/85020,789,3 %86,3 %79,6 %
T5-E24FDH-24-G5-L/P-16/55022,589,6 %86,5 %80,4 %
T5-E28FDH-28-G5-L/P-16/115027,889,8 %86,9 %81,8 %
T5-E35FDH-35-G5-L/P-16/145034,791,5 %89,0 %82,6 %
T5-E39FDH-39-G5-L/P-16/8503891,0 %88,4 %82,6 %
T5-E49FDH-49-G5-L/P-16/145049,391,6 %89,2 %84,6 %
T5-E54FDH-54-G5-L/P-16/115053,892,0 %89,7 %85,4 %
T5-E80FDH-80-G5-L/P-16/11508093,0 %90,9 %87,0 %
T5-E95FDH-95-G5-L/P-16/11509592,7 %90,5 %84,1 %
T5-E120FDH-120-G5-L/P-16/145012092,5 %90,2 %84,5 %
T5-C22FSCH-22-L/P-2GX13-16/22522,388,1 %84,8 %78,8 %
T5-C40FSCH-40-L/P-2GX13-16/30039,991,4 %88,9 %83,3 %
T5-C55FSCH-55-L/P-2GX13-16/3005592,4 %90,2 %84,6 %
T5-C60FSCH-60-L/P-2GX13-16/3756093,0 %90,9 %85,7 %
TC-LE40FSDH-40-L/P-2G114091,4 %88,9 %83,3 %
TC-LE55FSDH-55-L/P-2G115592,4 %90,2 %84,6 %
TC-LE80FSDH-80-L/P-2G118093,0 %90,9 %87,0 %
TC-TE32FSMH-32-L/P-2GX24q=33291,4 %88,9 %82,1 %
TC-TE42FSMH-42-L/P-2GX24q=44393,5 %91,5 %86,0 %
TC-TE57FSM6H-57-L/P-2GX24q=5FSM8H-57-L/P-2GX24q=55691,4 %88,9 %83,6 %
TC-TE70FSM6H-70-L/P-2GX24q=6FSM8H-70-L/P-2GX24q=67093,0 %90,9 %85,4 %
TC-TE60FSM6H-60-L/P-2G8=16392,3 %90,0 %84,0 %
TC-TE62FSM8H-62-L/P-2G8=26292,2 %89,9 %83,8 %
TC-TE82FSM8H-82-L/P-2G8=28292,4 %90,1 %83,7 %
TC-TE85FSM6H-85-L/P-2G8=18792,8 %90,6 %84,5 %
TC-TE120FSM6H-120-L/P-2G8=1FSM8H-120-L/P-2G8=112292,6 %90,4 %84,7 %
TC-DD55FSSH-55-L/P-GRY10q35592,4 %90,2 %84,6 %
In addition, non-dimmable ballasts not included in table 17 shall be assigned an EEI depending on their efficiency as described in Table 18:
Table 18Energy efficiency index requirements for non-dimmable ballasts for fluorescent lamps not included in Table 17
ηballastEnergy Efficiency Index
≥ 0,94 * EBbFLA3
≥ EBbFLA2
≥ 1-0,75*(1-EBbFL)A2 BAT
Where EBbFL is defined in Annex II.3.g.Furthermore, dimmable fluorescent lamp ballasts receive EEI classes according to the class into which the ballast would fall when it is operated at the 100 % lumen output, as described in Table 19.
Table 19Energy efficiency index requirements for dimmable ballasts for fluorescent lamps
Complied class at 100 % lumen outputEnergy Efficiency Index of dimmable ballast
A3A1
A2A1 BAT
Multi-wattage ballasts shall either be classified according to their efficiency under the lowest (worst) efficiency, or a relevant class shall be indicated for each operated lamp.
B.Second stage requirementsThree years after the entry into force of this Regulation:for ballasts for high intensity discharge lamps, the efficiency of the ballast as defined in Annex II.1.d shall be indicated.
3.REQUIREMENTS FOR LUMINAIRES FOR FLUORESCENT LAMPS WITHOUT INTEGRATED BALLAST AND FOR LUMINAIRES FOR HIGH INTENSITY DISCHARGE LAMPS3.1.Luminaire energy performance requirementsA.First stage requirementsOne year after this Regulation comes into force:the power consumption of luminaires for fluorescent lamps without integrated ballast shall not exceed the sum of the power consumption of the incorporated ballasts when the lamps they are normally operating do not emit any light when other possible connected components (network connections, sensors etc.) are disconnected. If they cannot be disconnected, their power shall be measured and deducted from the result.B.Second stage requirementsThree years after this Regulation comes into force:Luminaires for fluorescent lamps without integrated ballast and for high intensity discharge lamps shall be compatible with ballasts complying with the third stage requirements, except luminaires with ingress protection grade at least IP4X.The power consumption of luminaires for high intensity discharge lamps shall not exceed the sum of the power consumption of the incorporated ballasts when the lamps they are normally operating do not emit any light when other possible connected components (network connections, sensors etc.) are disconnected. If they cannot be disconnected, their power shall be measured and deducted from the result.C.Third stage requirementsEight years after this Regulation comes into force:All luminaires for fluorescent lamps without integrated ballast and for high intensity discharge lamps shall be compatible with ballasts complying with the third stage requirements.3.2.Product information requirements on luminairesA.First stage requirements18 months after this Regulation comes into force:Manufacturers of luminaires for fluorescent lamps without integrated ballast with total lamp lumen above 2000 lumen shall provide at least the following information on free-access websites and in other forms they deem appropriate for each of their luminaire models. That information shall also be contained in the technical documentation file drawn up for the purposes of conformity assessment pursuant to Article 8 of Directive 2005/32/EC:(a)if the luminaire is placed on the market together with the ballast, information on the efficiency of the ballast according to Annex III.2.2, in accordance with the ballast manufacturer’s data;(b)if the luminaire is placed on the market together with the lamp, lamp efficacy (lm/W) of the lamp, in accordance with the lamp manufacturer’s data;(c)if the ballast or the lamp are not placed on the market together with the luminaire, references used in manufacturers' catalogues must be provided on the types of lamps or ballasts compatible with the luminaire (e.g. ILCOS code for the lamps);(d)maintenance instructions to ensure that the luminaire maintains, as far as possible, its original quality throughout its lifetime;(e)disassembly instructions.B.Second stage requirementsThree years after this Regulation comes into force:the information provision requirements of the first stage shall also apply to luminaires for high intensity discharge lamps with total lamp lumen above 2000 lumen. In addition, all luminaires for high intensity discharge lamps shall indicate that they are designed for either clear and/or coated lamps within the meaning of Annex II.
ANNEX IVVerification procedure for market surveillance purposesWhen performing the market surveillance checks referred to in Article 3(2) of Directive 2005/32/EC, the authorities of the Member States shall apply the following verification procedure for the requirements set out in Annex III.Member States authorities shall use reliable, accurate and reproducible measurement procedures, which take into account the generally recognised state of the art measurement methods, including methods set out in documents the reference numbers of which have been published for that purpose in the Official Journal of the European Union.For lampsMember State authorities shall test a sample batch of minimum twenty lamps of the same model from the same manufacturer, randomly selected.The batch shall be considered to comply with the provisions set out in Annex III Part 1, as applicable, to this Regulation if the average results of the batch do not vary from the limit, threshold or declared values by more than 10 %.Otherwise, the model shall be considered not to comply.For ballasts and luminairesMember State authorities shall test one single unit.The model shall be considered to comply with the provisions set out in Annex III Parts 2 and 3, as applicable, to this Regulation if the results do not exceed the limit values.Otherwise, three more units shall be tested. The model shall be considered to comply with this Regulation if the average of the results of the latter three tests does not exceed the limit values.Otherwise, the model shall be considered not to comply.ANNEX VIndicative benchmarks for fluorescent and high intensity discharge products(for information)At the time of adoption of this Regulation, the best available technology on the market for the products concerned was identified as follows.1.Lamp efficacy and lamp lifeFor single and double capped fluorescent lamps, the benchmark values are the best values included in the tables in Annex III Parts 1.1 and 1.2.For high-intensity discharge lampsMetal Halide Lamps (clear and frosted):Table 20Indicative rated efficacy and performance values for metal halide lamps (benchmark level)
Ra ≥ 8080 > Ra ≥ 60
Nominal Lamp Wattage [W]Rated Lamp Efficacy [lm/W]Rated Lamp Efficacy [lm/W]
W ≤ 558095
55 < W ≤ 7590113
75 < W ≤ 10590116
105 < W ≤ 15598117
155 < W ≤ 255105
255 < W ≤ 405105
Burning HoursLamp Lumen Maintenance FactorLamp Survival Factor
12000> 0,80> 0,80
High-pressure sodium lamps (clear and frosted):Table 21Indicative rated efficacy and performance values for high pressure sodium lamps (benchmark level)
Nominal Lamp Wattage [W]Rated Lamp Efficacy [lm/W]
W ≤ 5588
55 < W ≤ 7591
75 < W ≤ 105107
105 < W ≤ 155110
155 < W ≤ 255128
255 < W ≤ 405138
Burning HoursLamp Lumen Maintenance FactorLamp Survival Factor
16000> 0,94> 0,92
2.Lamp mercury contentThe energy efficient fluorescent lamps with the lowest mercury content include not more than 1,4 mg mercury and the energy efficient high-intensity discharge lamps with the lowest mercury content include not more than 12 mg of mercury.3.Ballast performanceFor applications where dimming is beneficial, the benchmarks are as follows:Fluorescent lamp ballasts with energy efficiency index A1 BAT that are continuously dimmable down to 10 % light output.Ballasts for dimmable high intensity discharge lamps which can be dimmed down to 40 % light output having ballast efficiency of 0,9 (best known result, actual dimming possibilities may depend on the HID lamp type used with the ballast).4.Luminaire product informationThe following product information is provided on free-access websites and in other forms the manufacturers deem appropriate for benchmark luminaires in addition to the provisions in Annex III.3.2:CEN flux code of the luminaire or the complete photometric file.
ANNEX VIIndicative benchmarks for products meant to be installed as office lighting(for information)At the time of adoption of this Regulation, the best available technology on the market for the products concerned was identified as follows.1.LAMP BENCHMARKS1.1.Lamp performanceLamps have an efficacy according to Annex V.These lamps have the lamp lumen maintenance factors (LLMF) and lamp survival factors (LSF) in Table 22:
Table 22Indicative LLMF and LSF for office lighting lamps (benchmark level)
Burning hours20004000800016000
LLMF0,970,930,900,90
LSF0,990,990,980,93
In addition, these lamps are dimmable to 10 % or less of their light output.
1.2.Product information for lampsThe following information is provided on free-access websites and in other forms the manufacturers deem appropriate for lamps:The information required by Annex III.1.3, as applicable.
2.LIGHT SOURCE CONTROL GEAR BENCHMARKS2.1.Light source control gear performanceFluorescent lamp ballasts have an energy efficiency index of at least A1 (BAT) according to Annex III.2.2 and are dimmable.High intensity discharge lamp ballasts have an efficiency of 88 % (≤ 100 W lamp power) and else 90 % and are dimmable if the sum of lamp powers operated on the same ballast is above 50 W.Any other types of light source control gear have an efficiency of 88 % (≤ 100 W input power) and else 90 % when measured according to the applicable measurement standards and are dimmable for lamps above total input power 55 W.2.2.Product information for light source control gearThe following information is provided on free-access websites and in other forms the manufacturers deem appropriate for light source control gear:Information on the efficiency of the ballast or the applicable type of light source control gear.3.LUMINAIRE BENCHMARKS3.1.Luminaire performanceLuminaires have a luminaire maintenance factor LMF > 0,95 in normal office pollution degrees with a cleaning cycle of 4 years.If they are fluorescent or HID lamp luminaires, they are compatible with at least one lamp type complying with the benchmarks of Annex V.In addition, these luminaires are compatible with lighting control systems offering the following features:presence detection,light responsive dimming (for daylight and/or room reflectance variations),dimming to accompany changes in illumination requirements (during the working day, over a longer period or due to changes in functionality),dimming to compensate for: luminaire pollution, changes in lamp lumen output over its life time and changes in lamp efficacy when the lamp is replaced.The compatibility can also be ensured by incorporating the appropriate components in the luminaires themselves.The compatibility or the features offered by the incorporated components is indicated in the luminaire’s product documentation.3.2.Product information on luminairesThe following information is provided on free-access websites and in other forms the manufacturers deem appropriate for each of the luminaire models:The information required by Annex III.3.2 and Annex V, as applicable.In addition, for all luminaires, excluding luminaires with bare lamps and no optics, applicable luminaire maintenance factor (LMF) value data is provided with cleaning instructions if needed up to 4 years, using a similar table:
Table 23Indicative luminaire maintenance factor values (benchmark level)
LMF values
Environmentcleaning intervals in years
1,01,52,02,53,03,54,0
Very Clean
Clean
Normal (optional)
Dirty (optional)
The table is accompanied by a disclaimer that it contains only indicative values that may not reflect the achievable maintenance values in a particular installation.For luminaires for directional light sources such as reflector lamps or LEDs, only the applicable information is provided, e.g. LLMF × LMF instead of simply the LMF.
ANNEX VIIIndicative benchmarks for products meant to be installed as public street lighting(for information)At the time of adoption of this Regulation, the best available technology on the market for the products concerned was identified as follows.1.LAMP BENCHMARKS1.1.Lamp performanceLamps have an efficacy according to Annex V.These lamps have the lamp lumen maintenance factors (LLMF) and lamp survival factors (LSF) in Table 24:
Table 24Indicative LLMF and LSF for public street lighting lamps (benchmark level)
Burning hours20004000800016000
LLMF0,980,970,950,92
LSF0,990,980,950,92
In addition, these lamps are dimmable to at least 50 % of their light output when the rated lamp lumen output is above 9000 lumen.
1.2.Product information for lampsThe following information is provided on free-access websites and in other forms the manufacturers deem appropriate for lamps:The information required by Annex III.1.3, as applicable.
2.LIGHT SOURCE CONTROL GEAR BENCHMARKS2.1.Light source control gear performanceFluorescent lamp ballasts have an energy efficiency index of at least A1 BAT according to Annex III.2.2 and are dimmable.High intensity discharge lamp ballasts have an efficiency of above 87 % (≤ 100 W lamp power) and else above 89 % measured according to Annex II and are dimmable if the sum of lamp powers operated on the same ballast is above or equal to 55 W.Any other types of light source control gear have an efficiency of above 87 % (≤ 100 W input power) and else above 89 % when measured according to the applicable measurement standards and are dimmable for lamps equal or above total input power 55 W.2.2.Product information for light source control gearThe following information is provided on free-access websites and in other forms the manufacturers deem appropriate for light source control gear:Information on the efficiency of the ballast or the applicable type of light source control gear.3.LUMINAIRE BENCHMARKS3.1.Luminaire performanceLuminaires have an optical system that has an ingress protection rating as follows:IP65 for road classes ME1 to ME6 and MEW1 to MEW6IP5x for road classes CE0 to CE5, S1 to S6, ES, EV and AThe proportion of the light emitted by an optimally installed luminaire going above the horizon should be limited to:
Table 25Indicative maximum Upward Light Output Ratio (ULOR) values per road class for street lighting luminaires (at benchmark level)
Road classes ME1 to ME6 and MEW1 to MEW6, all lumen outputs3 %
Road classes CE0 to CE5, S1 to S6, ES, EV and A:
12000 lm ≤ light source5 %
8500 lm ≤ light source < 12000 lm10 %
3300 lm ≤ light source < 8500 lm15 %
light source < 3300 lm20 %
In areas where light pollution is of concern, the maximum proportion of the light going above the horizon is not more than 1 % for all road classes and lumen outputs.Luminaires are designed so that they avoid emitting obtrusive light to the maximum extent. However, any improvement of the luminaire aiming at reducing the emission of obtrusive light is not to the detriment of the overall energy efficiency of the installation for which it is designed.If they are luminaires for fluorescent or high-intensity discharge lamps, they are compatible with at least one lamp type complying with the benchmarks of Annex V.Luminaires are compatible with installations equipped with appropriate dimming and control systems that take account of daylight availability, traffic and weather conditions, and also compensate for the variation over time in surface reflection and for the initial dimensioning of the installation due to the lamp lumen maintenance factor.
3.2.Product information on luminairesThe following information is provided on free-access websites and in other forms the manufacturers deem appropriate for the relevant models:(a)the information required by Annex III.3.2 and Annex V, as applicable;(b)Utilisation Factor values for standard road conditions in tabular form for the defined road class. The table contains the most energy efficient UF values for different road widths, different pole heights, maximum pole distances, luminaire overhang and inclination, as appropriate for the given road class and luminaire design;(c)installation instructions for optimising the Utilisation Factor;(d)additional installation recommendations to minimise obtrusive light (if not conflicting with UF optimisation and safety);(e)for all luminaires, excluding luminaires with bare lamps and no optics, applicable luminaire maintenance factor (LMF) value data is provided according using a similar table:
Table 26Indicative luminaire maintenance factor values (benchmark level)
LMF values
Pollution categoryExposure time in years
1,01,52,02,53,03,54,0
High
Medium
Low
For luminaires for directional light sources such as reflector lamps or LEDs, only the applicable information is provided, e.g. LLMF × LMF instead of simply the LMF.