Commission Regulation (EC) No 107/2009 of 4 February 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for simple set-top boxes (Text with EEA relevance)
Modified by
- Commission Regulation (EU) 2016/2282of 30 November 2016amending Regulations (EC) No 1275/2008, (EC) No 107/2009, (EC) No 278/2009, (EC) No 640/2009, (EC) No 641/2009, (EC) No 642/2009, (EC) No 643/2009, (EU) No 1015/2010, (EU) No 1016/2010, (EU) No 327/2011, (EU) No 206/2012, (EU) No 547/2012, (EU) No 932/2012, (EU) No 617/2013, (EU) No 666/2013, (EU) No 813/2013, (EU) No 814/2013, (EU) No 66/2014, (EU) No 548/2014, (EU) No 1253/2014, (EU) 2015/1095, (EU) 2015/1185, (EU) 2015/1188, (EU) 2015/1189 and (EU) 2016/2281 with regard to the use of tolerances in verification procedures(Text with EEA relevance), 32016R2282, December 20, 2016
1. "Simple set-top box" (SSTB) means a stand-alone device which, irrespectively of the interfaces used, (a) has the primary function of converting standard-definition (SD) or high-definition (HD), free-to-air digital broadcast signals to analogue broadcast signals suitable for analogue television or radio; (b) has no "conditional access" (CA) function; (c) offers no recording function based on removable media in a standard library format.
A SSTB can be equipped with the following additional functions and/or components which do not constitute a minimum specification of an SSTB: (a) time-shift and recording functions using an integrated hard disk; (b) conversion of HD broadcast signal reception to HD or SD video output; (c) second tuner.
2. "Standby mode(s)" means a condition where the equipment is connected to the mains power source, depends on energy input from the mains power source to work as intended and provides only the following functions, which may persist for an indefinite time:(a) reactivation function, or reactivation function and only an indication of enabled reactivation function; and/or (b) information or status display.
3. "Reactivation function" means a function enabling the activation of other modes, including active mode, by remote switch, including remote control, internal sensor, timer to a condition providing additional functions, including the main function. 4. "Information or status display" means a continuous function providing information or indicating the status of the equipment in a display, including clocks. 5. "Active mode(s)" means a condition in which the equipment is connected to the mains power source and at least one of the main function(s) providing the intended service of the equipment has been activated. 6. "Automatic power down" means a function which switches the active mode of an SSTB into standby mode after a period in the active mode following the last user interaction and/or channel change. 7. "Second tuner" means a part of the SSTB available for independent recording while allowing to watch a different programme. 8. "Conditional access" (CA) means a provider-controlled broadcasting service requiring a market subscription television service.
Standby mode | Active mode | |
---|---|---|
Simple STB | ||
Allowance for display function in standby | — | |
Allowance for decoding HD signals | — |
Standby mode | Active mode | |
---|---|---|
Simple STB | ||
Allowance for display function in standby | — | |
Allowance for hard disk | — | |
Allowance for second tuner | — | |
Allowance for decoding HD signals | — |
the SSTB shall be automatically switched from active mode into standby after less than three hours in active mode following the last user interaction and/or a channel change with an alert message two minutes before going into standby mode. the "automatic power-down" function shall be set as default.
(a) For standby and active modes The power consumption data in Watts rounded to the second decimal place including consumption data for the different additional functions and/or components The measurement method used Period of measurement Description of how the appliance mode was selected or programmed Sequence of events to reach the mode where the equipment automatically changes modes Any notes regarding the operation of the equipment
(b) Test parameters for measurements Ambient temperature Test voltage in V and frequency in Hz Total harmonic distortion of the electricity supply system The fluctuation of the power supply voltage during the tests Information and documentation on the instrumentation, set-up and circuits used for electrical testing Input signals in RF (for digital terrestrial broadcasts) or IF (for satellite broadcasts) Audio/video test signals as described in the MPEG-2 transport stream Adjustment of controls
(1) The Member State authorities shall verify one single unit of the model. (2) The model shall be considered to comply with the applicable requirements if: (a) the values given in the technical documentation pursuant to point 2 of Annex IV to Directive 2009/125/EC (declared values), and, where applicable, the values used to calculate these values, are not more favourable for the manufacturer or importer than the results of the corresponding measurements carried out pursuant to paragraph (g) thereof; and (b) the declared values meet any requirements laid down in this Regulation, and any required product information published by the manufacturer or importer does not contain values that are more favourable for the manufacturer or importer than the declared values; and (c) when the Member State authorities test the unit of the model, the determined values (the values of the relevant parameters as measured in testing and the values calculated from these measurements) comply with the respective verification tolerances as given in Table 1.
(3) If the results referred to in point 2(a) or (b) are not achieved, the model shall be considered not to comply with this Regulation. (4) If the result referred to in point 2(c) is not achieved, the Member State authorities shall select three additional units of the same model for testing. (5) The model shall be considered to comply with the applicable requirements if, for these three units, the arithmetical mean of the determined values complies with the respective verification tolerances given in Table 1. (6) If the result referred to in point 5 is not achieved, the model shall be considered not to comply with this Regulation. (7) The Member State authorities shall provide all relevant information to the authorities of the other Member States and to the Commission without delay after a decision being taken on the non-compliance of the model according to points 3 and 6.
Provisions in Annex I, Points 1 and 2, as applicable | Verification tolerances |
---|---|
For power consumption above 1,00 W | The determined value shall not exceed the declared value by more than 10 %. |
For power consumption less than or equal to 1,00 W | The determined value shall not exceed the declared value by more than 0,10 W. |
SSTB without any additional features: Active mode: 4,00 W Standby mode excluding the display function: 0,25 W Off-mode: 0 W
SSTB with an integrated hard drive: Active mode: 10,00 W Standby mode excluding the display function: 0,25 W Off-mode 0 W:
Loading ...