Commission Regulation (EC) No 1275/2008 of 17 December 2008 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for standby and off mode electric power consumption of electrical and electronic household and office equipment (Text with EEA relevance)
Modified by
- Commission Regulation (EC) No 278/2009of 6 April 2009implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for no-load condition electric power consumption and average active efficiency of external power supplies(Text with EEA relevance), 32009R0278, April 7, 2009
- Commission Regulation (EC) No 642/2009of 22 July 2009implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for televisions(Text with EEA relevance), 32009R0642, July 23, 2009
- Commission Regulation (EU) No 617/2013of 26 June 2013implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for computers and computer servers(Text with EEA relevance), 32013R0617, June 27, 2013
- Commission Regulation (EU) No 801/2013of 22 August 2013amending Regulation (EC) No 1275/2008 with regard to ecodesign requirements for standby, off mode electric power consumption of electrical and electronic household and office equipment, and amending Regulation (EC) No 642/2009 with regard to ecodesign requirements for televisions(Text with EEA relevance), 32013R0801, August 23, 2013
- Commission Regulation (EU) 2016/2282of 30 November 2016amending Regulations (EC) No 1275/2008, (EC) No 107/2009, (EC) No 278/2009, (EC) No 640/2009, (EC) No 641/2009, (EC) No 642/2009, (EC) No 643/2009, (EU) No 1015/2010, (EU) No 1016/2010, (EU) No 327/2011, (EU) No 206/2012, (EU) No 547/2012, (EU) No 932/2012, (EU) No 617/2013, (EU) No 666/2013, (EU) No 813/2013, (EU) No 814/2013, (EU) No 66/2014, (EU) No 548/2014, (EU) No 1253/2014, (EU) 2015/1095, (EU) 2015/1185, (EU) 2015/1188, (EU) 2015/1189 and (EU) 2016/2281 with regard to the use of tolerances in verification procedures(Text with EEA relevance), 32016R2282, December 20, 2016
- Commission Regulation (EU) 2019/2021of 1 October 2019laying down ecodesign requirements for electronic displays pursuant to Directive 2009/125/EC of the European Parliament and of the Council, amending Commission Regulation (EC) No 1275/2008 and repealing Commission Regulation (EC) No 642/2009(Text with EEA relevance), 32019R2021, December 5, 2019
- Commission Regulation (EU) 2019/2022of 1 October 2019laying down ecodesign requirements for household dishwashers pursuant to Directive 2009/125/EC of the European Parliament and of the Council amending Commission Regulation (EC) No 1275/2008 and repealing Commission Regulation (EU) No 1016/2010(Text with EEA relevance), 32019R2022, December 5, 2019
- Commission Regulation (EU) 2019/2023of 1 October 2019laying down ecodesign requirements for household washing machines and household washer-dryers pursuant to Directive 2009/125/EC of the European Parliament and of the Council, amending Commission Regulation (EC) No 1275/2008 and repealing Commission Regulation (EU) No 1015/2010(Text with EEA relevance), 32019R2023, December 5, 2019
1. "electrical and electronic household and office equipment" (hereafter referred to as "equipment"), means any energy-using product which: (a) is made commercially available as a single functional unit and is intended for the end-user; (b) falls under the list of energy-using products of Annex I; (c) is dependent on energy input from the mains power source in order to work as intended; and (d) is designed for use with a nominal voltage rating of 250 V or below,
also when marketed for non-household or non-office use; 2. "standby mode(s)" means a condition where the equipment is connected to the mains power source, depends on energy input from the mains power source to work as intended and provides only the following functions, which may persist for an indefinite time:reactivation function, or reactivation function and only an indication of enabled reactivation function, and/or information or status display;
3. "reactivation function" means a function facilitating the activation of other modes, including active mode, by remote switch, including remote control, internal sensor, timer to a condition providing additional functions, including the main function; 4. "information or status display" means a continuous function providing information or indicating the status of the equipment on a display, including clocks; 5. "active mode(s)" means a condition in which the equipment is connected to the mains power source and at least one of the main function(s) providing the intended service of the equipment has been activated; 6. "off mode" means a condition in which the equipment is connected to the mains power source and is not providing any function; the following shall also be considered as off mode: (a) conditions providing only an indication of off-mode condition; (b) conditions providing only functionalities intended to ensure electromagnetic compatibility pursuant to Directive 2004/108/EC of the European Parliament and of the Council ;OJ L 390, 31.12.2004, p. 24 .
7. "information technology equipment" means any equipment which has a primary function of either entry, storage, display, retrieval, transmission, processing, switching, or control, of data and of telecommunication messages or a combination of these functions and may be equipped with one or more terminal ports typically operated for information transfer; 8. "domestic environment" means an environment where the use of broadcast radio and television receivers may be expected within a distance of 10 m of the apparatus concerned; 9. "low voltage external power supply" means an external power supply with a nameplate output voltage of less than 6 volts and a nameplate output current greater than or equal to 550 milliamperes; 10. "network" means a communication infrastructure with a topology of links, an architecture, including the physical components, organisational principles, communication procedures and formats (protocols); 11. "networked standby" means a condition in which the equipment is able to resume a function by way of a remotely initiated trigger from a network connection; 12. "remotely initiated trigger" means a signal that comes from outside the equipment via a network; 13. "network port" means a wired or wireless physical interface of the network connection located on the equipment through which the equipment can be remotely activated; 14. "logical network port" means the network technology running over a physical network port; 15. "physical network port" means the physical (hardware) medium of a network port. A physical network port can host two or more network technologies; 16. "network availability" means the capability of the equipment to resume functions after a remotely initiated trigger has been detected by a network port; 17. "networked equipment" means equipment that can connect to a network and has one or more network ports; 18. "networked equipment with high network availability" (HiNA equipment) means equipment with one or more of the following functionalities, but no other, as the main function(s): router, network switch, wireless network access point, hub, modem, VoIP telephone, video phone; 19. "networked equipment with high network availability functionality" (equipment with HiNA functionality) means equipment with the functionality of a router, network switch, wireless network access point or combination thereof included, but not being HiNA equipment; 20. "router" means a network device whose primary function is to determine the optimal path along which network traffic should be forwarded. Routers forward packets from one network to another, based on network layer information (L3); 21. "network switch" means a network device whose primary function is to filter, forward and distribute frames based on the destination address of each frame. All switches operate at least at the data link layer (L2); 22. "wireless network access point" means a device whose primary function is to provide IEEE 802.11 (Wi-Fi) connectivity to multiple clients; 23. "hub" means a network device that contains multiple ports and is used to connect segments of a Local Area Network; 24. "modem" means a device whose primary function is to transmit and receive digitally modulated analogue signals over a wired network; 25. "printing equipment" means equipment that generates paper output from electronic input. Printing equipment may have additional functions and may be marketed as a multifunctional device or multifunctional product; 26. "large format printing equipment" means printing equipment designed for printing on A2 media and larger, including equipment designed to accommodate continuous-form media of at least 406 mm width; 27. "tele-presence system" means a dedicated system for high-definition video conferencing and collaboration which includes a user interface, a high-definition camera, a display, a sound system and processing capabilities for encoding and decoding video and audio; 28. "household coffee machine" means a non-commercial appliance for brewing coffee; 29. "drip filter household coffee machine" means a household coffee machine which uses percolation to extract the coffee; 30. "heating element" means a component of the coffee machine which converts electricity into heat to warm up water; 31. "cup preheating" means a function for warming cups that are stored on the coffee machine; 32. "brewing cycle" means the process that has to be completed to produce coffee; 33. "self-cleaning" means a process that the coffee machine carries out to clean its interior. This process can either be a simple rinse or a washing process using specific additives; 34. "descaling" means a process that the coffee machine carries out to remove totally or partially potential scale in its interior; 35. "desktop thin client" means a computer that relies on a connection to remote computing resources (e.g. computer server, remote workstation) to obtain primary functionality and has no rotational storage media integral to the product. The main unit of a desktop thin client must be intended for use in a permanent location (e.g. on a desk) and not for portability. Desktop thin clients can output information to either an external or, where included with the product, an internal display; 36. "workstation" means a high-performance, single-user computer primarily used for graphics, Computer Aided Design, software development, financial and scientific applications among other compute intensive tasks, and which has the following characteristics: (a) has a mean time between failures (MTBF) of at least 15000 hours;(b) has error-correcting code (ECC) and/or buffered memory; (c) meets three of the following five characteristics: (1) has supplemental power support for high-end graphics (i.e. peripheral component interconnect (PCI)-E 6-pin 12 V supplemental power feed); (2) its system is wired for greater than × 4 PCI-E on the motherboard in addition to the graphics slot(s) and/or PCI-X support; (3) does not support uniform memory access (UMA) graphics; (4) includes five or more PCI, PCI-E or PCI-X slots; (5) is capable of multi-processor support for two or more CPU (must support physically separate CPU packages/sockets, i.e. not met with support for a single multi core CPU);
37. "mobile workstation" means a high-performance, single-user computer primarily used for graphics, Computer Aided Design, software development, financial and scientific applications among other compute intensive tasks, excluding game play, and which is designed specifically for portability and to be operated for extended periods of time either with or without a direct connection to an AC power source. Mobile workstations utilise an integrated display and are capable of operation on an integrated battery or other portable power source. Most mobile workstations use an external power supply and most have an integrated keyboard and pointing device. A mobile workstation has the following characteristics: (a) has a mean time between failures (MTBF) of at least 13000 hours;(b) has at least one discrete graphics card (dGfx) meeting the G3 (with FB Data Width > 128-bit), G4, G5, G6 or G7 classification; (c) supports the inclusion of three or more internal storage devices; (d) supports at least 32 GB of system memory;
38. "small-scale server" means a type of computer that typically uses desktop computer components in a desktop form factor but is designed primarily to be a storage host for other computers and to perform functions such as providing network infrastructure services and hosting data/media, and which has the following characteristics: (a) is designed in a pedestal, tower, or other form factor similar to those of desktop computers such that all data processing, storage, and network interfacing is contained within one box; (b) is designed to be operational 24 hours per day and 7 days per week; (c) is primarily designed to operate in a simultaneous multi-user environment serving several users through networked client units; (d) where placed on the market with an operating system, the operating system is designed for home server or low-end server applications; (e) is not placed on the market with a discrete graphics card (dGfx) meeting any classification other than G1;
39. "computer server" means a computing product that provides services and manages networked resources for client devices, such as desktop computers, notebook computers, desktop thin clients, internet protocol (IP) telephones, or other computer servers. A computer server is typically placed on the market for use in data centres and office/corporate environments. A computer server is primarily accessed via network connections, and not through direct user input devices, such as a keyboard or a mouse; A computer server has the following characteristics: (a) is designed to support computer server operating systems (OS) and/or hypervisors, and targeted to run user-installed enterprise applications; (b) supports error-correcting code (ECC) and/or buffered memory (including both buffered dual in-line memory modules (DIMMs) and buffered on board (BOB) configurations); (c) is placed on the market with one or more AC-DC power supply(ies); (d) all processors have access to shared system memory and are independently visible to a single OS or hypervisor.
1. Household appliances Washing machines Clothes dryers Dish washing machines Cooking: Electric ovens Electric hot plates Microwave ovens Toasters Fryers Grinders, coffee machines and equipment for opening or sealing containers or packages Electric knives Other appliances for cooking and other processing of food, cleaning and maintenance of clothes with the exception of household washing machines and household washer-dryers Appliances for hair cutting, hair drying, tooth brushing, shaving, massage and other body care appliances Scales 2. Information technology equipment intended primarily for use in the domestic environment, but excluding desktop computers, integrated desktop computers and notebook computers as defined in Commission Regulation (EU) No 617/2013, as well as electronic displays covered by Regulation (EU) 2019/2021 .Commission Regulation (EU) 2019/2021 of 1 October 2019 laying down eco-design requirements for electronic displays pursuant to Directive 2009/125/EC of the European Parliament and of the Council, amending Commission Regulation (EC) No 1275/2008 and repealing Commission Regulation (EC) 642/2009 (OJ L 315, 5.12.2019, p. 241 ).3. Consumer equipment Radio sets Videocameras Video recorders Hi-fi recorders Audio amplifiers Home theatre systems Musical instruments And other equipment for the purpose of recording or reproducing sound or images, including signals or other technologies for the distribution of sound and image other than by telecommunications, but excluding electronic displays covered by Regulation (EU) 2019/2021 4. Toys, leisure and sports equipment Electric trains or car racing sets Hand-held video game consoles Sports equipment with electric or electronic components Other toys, leisure and sport equipment
(a) Power consumption in "off mode": Power consumption of equipment in any off-mode condition shall not exceed 1,00 W. (b) Power consumption in "standby mode(s)": The power consumption of equipment in any condition providing only a reactivation function, or providing only a reactivation function and a mere indication of enabled reactivation function, shall not exceed 1,00 W. The power consumption of equipment in any condition providing only information or status display, or providing only a combination of reactivation function and information or status display, shall not exceed 2,00 W. (c) Availability of off mode and/or standby mode Equipment shall, except where this is inappropriate for the intended use, provide off mode and/or standby mode, and/or another condition which does not exceed the applicable power consumption requirements for off mode and/or standby mode when the equipment is connected to the mains power source.
(a) Power consumption in "off mode": Power consumption of equipment in any off-mode condition shall not exceed 0,50 W. (b) Power consumption in "standby mode(s)": The power consumption of equipment in any condition providing only a reactivation function, or providing only a reactivation function and a mere indication of enabled reactivation function, shall not exceed 0,50 W. The power consumption of equipment in any condition providing only information or status display, or providing only a combination of reactivation function and information or status display shall not exceed 1,00 W. (c) Availability of off mode and/or standby mode Equipment shall, except where this is inappropriate for the intended use, provide off mode and/or standby mode, and/or another condition which does not exceed the applicable power consumption requirements for off mode and/or standby mode when the equipment is connected to the mains power source. (d) Power management for all equipment other than networked equipment Equipment shall, unless inappropriate for the intended use, offer a power management function or a similar function. When equipment is not providing the main function, and other energy-using product(s) are not dependent on its functions, the power management function shall switch equipment after the shortest possible period of time appropriate for the intended use of the equipment, automatically into: standby mode, or off mode, or another condition which does not exceed the applicable power consumption requirements for off mode and/or standby mode when the equipment is connected to the mains power source.
The power management function shall be activated.
(a) Possibility of deactivating wireless network connection(s) Any networked equipment that can be connected to a wireless network shall offer the user the possibility to deactivate the wireless network connection(s). This requirement does not apply to products which rely on a single wireless network connection for intended use and have no wired network connection. (b) Power management for networked equipment Equipment shall, unless inappropriate for the intended use, offer a power management function or a similar function. When equipment is not providing a main function, and other energy-using product(s) are not dependent on its functions, the power management function shall switch equipment after the shortest possible period of time appropriate for the intended use of the equipment, automatically into a condition having networked standby. In a condition providing networked standby, the power management function may switch equipment automatically into standby mode or off mode or another condition which does not exceed the applicable power consumption requirements for standby and/or off mode. The power management function, or a similar function, shall be available for all network ports of the networked equipment. The power management function, or a similar function, shall be activated, unless all network ports are deactivated. In that latter case the power management function, or a similar function, shall be activated if any of the network ports is activated. The default period of time after which the power management function, or a similar function, switches the equipment automatically into a condition providing networked standby shall not exceed 20 minutes. (c) Networked equipment that has one or more standby modes shall comply with the requirements for these standby mode(s) when all network ports are deactivated. (d) Networked equipment other than HiNA equipment shall comply with the provisions under 2(d) when all network ports are deactivated. (e) Power consumption in a condition providing networked standby: The power consumption of HiNA equipment or equipment with HiNA functionality in a condition providing networked standby into which the equipment is switched by the power management function, or a similar function shall not exceed 12,00 W. The power consumption of other networked equipment in a condition providing networked standby into which the equipment is switched by the power management function, or a similar function, shall not exceed 6,00 W. The power consumption limits as stipulated in point (e) shall not apply to: (i) printing equipment with a power supply of a rated power larger than 750 W; (ii) large format printing equipment; (iii) tele-presence systems; (iv) desktop thin clients; (v) workstations; (vi) mobile workstations; (vii) small-scale servers; (viii) computer servers.
(a) Networked equipment that has one or more standby mode(s) shall comply with the requirements for these standby mode(s) when all wired network ports are disconnected and when all wireless network ports are deactivated. (b) Networked equipment other than HiNA equipment shall comply with the provisions under 2(d) when all wired network ports are disconnected and when all wireless network ports are deactivated. (c) Power consumption in a condition providing "networked standby": The power consumption of HiNA equipment or equipment with HiNA functionality, in a condition providing networked standby into which the equipment is switched by the power management function, or a similar function, shall not exceed 8,00 W. The power consumption of other networked equipment in a condition providing networked standby into which the equipment is switched by the power management function, or a similar function, shall not exceed 3,00 W. The power consumption limits as stipulated in point (c) shall not apply to: (i) large format printing equipment; (ii) desktop thin clients; (iii) workstations; (iv) mobile workstations; (v) small-scale servers; (vi) computer servers.
for domestic drip filter coffee machines storing the coffee in an insulated jug, a maximum of five minutes after completion of the last brewing cycle or 30 minutes after completion of a descaling or self-cleaning process, for domestic drip filter coffee machines storing the coffee in a non-insulated jug, a maximum of 40 minutes after completion of the last brewing cycle, or 30 minutes after completion of a descaling or self-cleaning process, for domestic coffee machines other than drip filter coffee machines, a maximum of 30 minutes after completion of the last brewing cycle, or a maximum of 30 minutes after activation of the heating element, or a maximum of 60 minutes after activation of the cup preheating function, or a maximum of 30 minutes after completion of a descaling or self-cleaning process, unless an alarm has been triggered requiring users’ intervention to prevent possible damage or accident.
(a) for each standby and/or off mode and the condition providing networked standby into which the equipment is switched by the power management function or similar function: the power consumption data in Watt rounded to the first decimal place, the period of time after which the power management function, or a similar function, switches the equipment automatically into standby and/or off mode and/or the condition providing networked standby;
(b) the power consumption of the product in networked standby if all wired network ports are connected and all wireless network ports are activated; (c) guidance on how to activate and deactivate wireless network ports.
(a) for each standby and/or off mode: the power consumption data in Watt rounded to the first decimal place, the measurement method used, a description of how the equipment mode was selected or programmed, the sequence of events leading to the condition where the equipment automatically changes modes, any notes regarding the operation of the equipment, e.g. information on how the user switches the equipment into a condition having networked standby, if applicable, the default time after which the power management function, or similar function, has switched the equipment into the applicable low power mode or condition;
(b) for networked equipment: the number and type of network ports and, with the exception of wireless network ports, where these ports are located on the equipment; in particular it shall be declared if the same physical network port accommodates two or more types of network ports, whether all network ports are deactivated before delivery, whether the equipment qualifies as HiNA equipment or equipment with HiNa functionality; where no information is provided, this is considered not to be the case;
and for each type of network port: the default time after which the power management function, or a similar function, switches the equipment into a condition providing networked standby, the trigger that is used to reactivate the equipment, the (maximum) performance specifications, the (maximum) power consumption of the equipment in a condition providing networked standby into which the power management function, or a similar function, will switch the equipment, if only this port is used for remote activation, the communication protocol used by the equipment;
If no information is provided, the equipment is considered not to be networked equipment unless it provides the functionalities of a router, network switch, wireless network access point (not being a terminal), hub, modem, VoIP telephone, video phone. (c) test parameters for measurements: ambient temperature, test voltage in V and frequency in Hz, total harmonic distortion of the electricity supply system, information and documentation on the instrumentation, set-up and circuits used for electrical testing;
(d) the equipment characteristics relevant for assessing conformity with the requirements set out in point 1(c), or the requirements set out in points 2(c) and/or 2(d) and/or 3(b), as applicable, including the time taken to automatically reach standby, or off mode, or another condition which does not exceed the applicable power consumption requirements for off mode and/or standby mode. In particular, if applicable, a technical justification shall be provided that the requirements set out in point 1(c), or the requirements set out in points 2(c) and/or 2(d) and/or 3(b), are inappropriate for the intended use of equipment. The need to maintain one or more network connections or to wait for a remotely initiated trigger is not considered a technical justification for exemption from the requirements set out in 2(d) in the case of equipment that is not defined as networked equipment by the manufacturer.
(1) The Member State authorities shall verify one single unit of the model. (2) The model shall be considered to comply with the applicable requirements if: (a) the values given in the technical documentation pursuant to point 2 of Annex IV to Directive 2009/125/EC (declared values), and, where applicable, the values used to calculate these values, are not more favourable for the manufacturer or importer than the results of the corresponding measurements carried out pursuant to paragraph (g) thereof; and (b) the declared values meet any requirements laid down in this Regulation, and any required product information published by the manufacturer or importer does not contain values that are more favourable for the manufacturer or importer than the declared values; and (c) when the Member State authorities test the unit of the model, the determined values (the values of the relevant parameters as measured in testing and the values calculated from these measurements) comply with the respective verification tolerances as given in the table below.
(3) If the results referred to in point 2(a) or (b) are not achieved, the model shall be considered not to comply with this Regulation. (4) If the result referred to in point 2(c) is not achieved, the Member State authorities shall select three additional units of the same model for testing. (5) The model shall be considered to comply with the applicable requirements if, for these three units, the arithmetical mean of the determined values complies with the respective verification tolerances given in the table below. (6) If the result referred to in point 5 is not achieved, the model shall be considered not to comply with this Regulation. (7) The Member State authorities shall provide all relevant information to the authorities of the other Member States and to the Commission without delay after a decision being taken on the non-compliance of the model according to points 3 and 6.
Type of requirement | Category | Tolerance |
---|---|---|
Annex II, points 1(a) and (b), or points 2(a) and (b) | For power consumption requirements above 1,00 W | The determined value shall not exceed the declared value by more than 10 %. |
For power consumption requirements less than or equal to 1,00 W | The determined value shall not exceed the declared value by more than 0,10 W. | |
Annex II, points 3(c) and 4(a) | n/a | The determined value shall not exceed the declared value by more than 10 %. |
1. "electrical and electronic household and office equipment" (hereafter referred to as "equipment"), means any energy-using product which: (a) is made commercially available as a single functional unit and is intended for the end-user; (b) falls under the list of energy-using products of Annex I; (c) is dependent on energy input from the mains power source in order to work as intended; and (d) is designed for use with a nominal voltage rating of 250 V or below,
also when marketed for non-household or non-office use; 2. "standby mode(s)" means a condition where the equipment is connected to the mains power source, depends on energy input from the mains power source to work as intended and provides only the following functions, which may persist for an indefinite time:reactivation function, or reactivation function and only an indication of enabled reactivation function, and/or information or status display;
3. "reactivation function" means a function facilitating the activation of other modes, including active mode, by remote switch, including remote control, internal sensor, timer to a condition providing additional functions, including the main function; 4. "information or status display" means a continuous function providing information or indicating the status of the equipment on a display, including clocks; 5. "active mode(s)" means a condition in which the equipment is connected to the mains power source and at least one of the main function(s) providing the intended service of the equipment has been activated; 6. "off mode" means a condition in which the equipment is connected to the mains power source and is not providing any function; the following shall also be considered as off mode: (a) conditions providing only an indication of off-mode condition; (b) conditions providing only functionalities intended to ensure electromagnetic compatibility pursuant to Directive 2004/108/EC of the European Parliament and of the Council ;OJ L 390, 31.12.2004, p. 24 .
7. "information technology equipment" means any equipment which has a primary function of either entry, storage, display, retrieval, transmission, processing, switching, or control, of data and of telecommunication messages or a combination of these functions and may be equipped with one or more terminal ports typically operated for information transfer; 8. "domestic environment" means an environment where the use of broadcast radio and television receivers may be expected within a distance of 10 m of the apparatus concerned; 9. "low voltage external power supply" means an external power supply with a nameplate output voltage of less than 6 volts and a nameplate output current greater than or equal to 550 milliamperes; 10. "network" means a communication infrastructure with a topology of links, an architecture, including the physical components, organisational principles, communication procedures and formats (protocols); 11. "networked standby" means a condition in which the equipment is able to resume a function by way of a remotely initiated trigger from a network connection; 12. "remotely initiated trigger" means a signal that comes from outside the equipment via a network; 13. "network port" means a wired or wireless physical interface of the network connection located on the equipment through which the equipment can be remotely activated; 14. "logical network port" means the network technology running over a physical network port; 15. "physical network port" means the physical (hardware) medium of a network port. A physical network port can host two or more network technologies; 16. "network availability" means the capability of the equipment to resume functions after a remotely initiated trigger has been detected by a network port; 17. "networked equipment" means equipment that can connect to a network and has one or more network ports; 18. "networked equipment with high network availability" (HiNA equipment) means equipment with one or more of the following functionalities, but no other, as the main function(s): router, network switch, wireless network access point, hub, modem, VoIP telephone, video phone; 19. "networked equipment with high network availability functionality" (equipment with HiNA functionality) means equipment with the functionality of a router, network switch, wireless network access point or combination thereof included, but not being HiNA equipment; 20. "router" means a network device whose primary function is to determine the optimal path along which network traffic should be forwarded. Routers forward packets from one network to another, based on network layer information (L3); 21. "network switch" means a network device whose primary function is to filter, forward and distribute frames based on the destination address of each frame. All switches operate at least at the data link layer (L2); 22. "wireless network access point" means a device whose primary function is to provide IEEE 802.11 (Wi-Fi) connectivity to multiple clients; 23. "hub" means a network device that contains multiple ports and is used to connect segments of a Local Area Network; 24. "modem" means a device whose primary function is to transmit and receive digitally modulated analogue signals over a wired network; 25. "printing equipment" means equipment that generates paper output from electronic input. Printing equipment may have additional functions and may be marketed as a multifunctional device or multifunctional product; 26. "large format printing equipment" means printing equipment designed for printing on A2 media and larger, including equipment designed to accommodate continuous-form media of at least 406 mm width; 27. "tele-presence system" means a dedicated system for high-definition video conferencing and collaboration which includes a user interface, a high-definition camera, a display, a sound system and processing capabilities for encoding and decoding video and audio; 28. "household coffee machine" means a non-commercial appliance for brewing coffee; 29. "drip filter household coffee machine" means a household coffee machine which uses percolation to extract the coffee; 30. "heating element" means a component of the coffee machine which converts electricity into heat to warm up water; 31. "cup preheating" means a function for warming cups that are stored on the coffee machine; 32. "brewing cycle" means the process that has to be completed to produce coffee; 33. "self-cleaning" means a process that the coffee machine carries out to clean its interior. This process can either be a simple rinse or a washing process using specific additives; 34. "descaling" means a process that the coffee machine carries out to remove totally or partially potential scale in its interior; 35. "desktop thin client" means a computer that relies on a connection to remote computing resources (e.g. computer server, remote workstation) to obtain primary functionality and has no rotational storage media integral to the product. The main unit of a desktop thin client must be intended for use in a permanent location (e.g. on a desk) and not for portability. Desktop thin clients can output information to either an external or, where included with the product, an internal display; 36. "workstation" means a high-performance, single-user computer primarily used for graphics, Computer Aided Design, software development, financial and scientific applications among other compute intensive tasks, and which has the following characteristics: (a) has a mean time between failures (MTBF) of at least 15000 hours;(b) has error-correcting code (ECC) and/or buffered memory; (c) meets three of the following five characteristics: (1) has supplemental power support for high-end graphics (i.e. peripheral component interconnect (PCI)-E 6-pin 12 V supplemental power feed); (2) its system is wired for greater than × 4 PCI-E on the motherboard in addition to the graphics slot(s) and/or PCI-X support; (3) does not support uniform memory access (UMA) graphics; (4) includes five or more PCI, PCI-E or PCI-X slots; (5) is capable of multi-processor support for two or more CPU (must support physically separate CPU packages/sockets, i.e. not met with support for a single multi core CPU);
37. "mobile workstation" means a high-performance, single-user computer primarily used for graphics, Computer Aided Design, software development, financial and scientific applications among other compute intensive tasks, excluding game play, and which is designed specifically for portability and to be operated for extended periods of time either with or without a direct connection to an AC power source. Mobile workstations utilise an integrated display and are capable of operation on an integrated battery or other portable power source. Most mobile workstations use an external power supply and most have an integrated keyboard and pointing device. A mobile workstation has the following characteristics: (a) has a mean time between failures (MTBF) of at least 13000 hours;(b) has at least one discrete graphics card (dGfx) meeting the G3 (with FB Data Width > 128-bit), G4, G5, G6 or G7 classification; (c) supports the inclusion of three or more internal storage devices; (d) supports at least 32 GB of system memory;
38. "small-scale server" means a type of computer that typically uses desktop computer components in a desktop form factor but is designed primarily to be a storage host for other computers and to perform functions such as providing network infrastructure services and hosting data/media, and which has the following characteristics: (a) is designed in a pedestal, tower, or other form factor similar to those of desktop computers such that all data processing, storage, and network interfacing is contained within one box; (b) is designed to be operational 24 hours per day and 7 days per week; (c) is primarily designed to operate in a simultaneous multi-user environment serving several users through networked client units; (d) where placed on the market with an operating system, the operating system is designed for home server or low-end server applications; (e) is not placed on the market with a discrete graphics card (dGfx) meeting any classification other than G1;
39. "computer server" means a computing product that provides services and manages networked resources for client devices, such as desktop computers, notebook computers, desktop thin clients, internet protocol (IP) telephones, or other computer servers. A computer server is typically placed on the market for use in data centres and office/corporate environments. A computer server is primarily accessed via network connections, and not through direct user input devices, such as a keyboard or a mouse; A computer server has the following characteristics: (a) is designed to support computer server operating systems (OS) and/or hypervisors, and targeted to run user-installed enterprise applications; (b) supports error-correcting code (ECC) and/or buffered memory (including both buffered dual in-line memory modules (DIMMs) and buffered on board (BOB) configurations); (c) is placed on the market with one or more AC-DC power supply(ies); (d) all processors have access to shared system memory and are independently visible to a single OS or hypervisor.
1. Household appliances Washing machines Clothes dryers Dish washing machines Cooking: Electric ovens Electric hot plates Microwave ovens Toasters Fryers Grinders, coffee machines and equipment for opening or sealing containers or packages Electric knives Other appliances for cooking and other processing of food, cleaning and maintenance of clothes with the exception of household washing machines and household washer-dryers Appliances for hair cutting, hair drying, tooth brushing, shaving, massage and other body care appliances Scales 2. Information technology equipment intended primarily for use in the domestic environment, but excluding desktop computers, integrated desktop computers and notebook computers as defined in Commission Regulation (EU) No 617/2013, as well as electronic displays covered by Regulation (EU) 2019/2021 .Commission Regulation (EU) 2019/2021 of 1 October 2019 laying down eco-design requirements for electronic displays pursuant to Directive 2009/125/EC of the European Parliament and of the Council, amending Commission Regulation (EC) No 1275/2008 and repealing Commission Regulation (EC) 642/2009 (OJ L 315, 5.12.2019, p. 241 ).3. Consumer equipment Radio sets Videocameras Video recorders Hi-fi recorders Audio amplifiers Home theatre systems Musical instruments And other equipment for the purpose of recording or reproducing sound or images, including signals or other technologies for the distribution of sound and image other than by telecommunications, but excluding electronic displays covered by Regulation (EU) 2019/2021 4. Toys, leisure and sports equipment Electric trains or car racing sets Hand-held video game consoles Sports equipment with electric or electronic components Other toys, leisure and sport equipment
(a) Power consumption in "off mode": Power consumption of equipment in any off-mode condition shall not exceed 1,00 W. (b) Power consumption in "standby mode(s)": The power consumption of equipment in any condition providing only a reactivation function, or providing only a reactivation function and a mere indication of enabled reactivation function, shall not exceed 1,00 W. The power consumption of equipment in any condition providing only information or status display, or providing only a combination of reactivation function and information or status display, shall not exceed 2,00 W. (c) Availability of off mode and/or standby mode Equipment shall, except where this is inappropriate for the intended use, provide off mode and/or standby mode, and/or another condition which does not exceed the applicable power consumption requirements for off mode and/or standby mode when the equipment is connected to the mains power source.
(a) Power consumption in "off mode": Power consumption of equipment in any off-mode condition shall not exceed 0,50 W. (b) Power consumption in "standby mode(s)": The power consumption of equipment in any condition providing only a reactivation function, or providing only a reactivation function and a mere indication of enabled reactivation function, shall not exceed 0,50 W. The power consumption of equipment in any condition providing only information or status display, or providing only a combination of reactivation function and information or status display shall not exceed 1,00 W. (c) Availability of off mode and/or standby mode Equipment shall, except where this is inappropriate for the intended use, provide off mode and/or standby mode, and/or another condition which does not exceed the applicable power consumption requirements for off mode and/or standby mode when the equipment is connected to the mains power source. (d) Power management for all equipment other than networked equipment Equipment shall, unless inappropriate for the intended use, offer a power management function or a similar function. When equipment is not providing the main function, and other energy-using product(s) are not dependent on its functions, the power management function shall switch equipment after the shortest possible period of time appropriate for the intended use of the equipment, automatically into: standby mode, or off mode, or another condition which does not exceed the applicable power consumption requirements for off mode and/or standby mode when the equipment is connected to the mains power source.
The power management function shall be activated.
(a) Possibility of deactivating wireless network connection(s) Any networked equipment that can be connected to a wireless network shall offer the user the possibility to deactivate the wireless network connection(s). This requirement does not apply to products which rely on a single wireless network connection for intended use and have no wired network connection. (b) Power management for networked equipment Equipment shall, unless inappropriate for the intended use, offer a power management function or a similar function. When equipment is not providing a main function, and other energy-using product(s) are not dependent on its functions, the power management function shall switch equipment after the shortest possible period of time appropriate for the intended use of the equipment, automatically into a condition having networked standby. In a condition providing networked standby, the power management function may switch equipment automatically into standby mode or off mode or another condition which does not exceed the applicable power consumption requirements for standby and/or off mode. The power management function, or a similar function, shall be available for all network ports of the networked equipment. The power management function, or a similar function, shall be activated, unless all network ports are deactivated. In that latter case the power management function, or a similar function, shall be activated if any of the network ports is activated. The default period of time after which the power management function, or a similar function, switches the equipment automatically into a condition providing networked standby shall not exceed 20 minutes. (c) Networked equipment that has one or more standby modes shall comply with the requirements for these standby mode(s) when all network ports are deactivated. (d) Networked equipment other than HiNA equipment shall comply with the provisions under 2(d) when all network ports are deactivated. (e) Power consumption in a condition providing networked standby: The power consumption of HiNA equipment or equipment with HiNA functionality in a condition providing networked standby into which the equipment is switched by the power management function, or a similar function shall not exceed 12,00 W. The power consumption of other networked equipment in a condition providing networked standby into which the equipment is switched by the power management function, or a similar function, shall not exceed 6,00 W. The power consumption limits as stipulated in point (e) shall not apply to: (i) printing equipment with a power supply of a rated power larger than 750 W; (ii) large format printing equipment; (iii) tele-presence systems; (iv) desktop thin clients; (v) workstations; (vi) mobile workstations; (vii) small-scale servers; (viii) computer servers.
(a) Networked equipment that has one or more standby mode(s) shall comply with the requirements for these standby mode(s) when all wired network ports are disconnected and when all wireless network ports are deactivated. (b) Networked equipment other than HiNA equipment shall comply with the provisions under 2(d) when all wired network ports are disconnected and when all wireless network ports are deactivated. (c) Power consumption in a condition providing "networked standby": The power consumption of HiNA equipment or equipment with HiNA functionality, in a condition providing networked standby into which the equipment is switched by the power management function, or a similar function, shall not exceed 8,00 W. The power consumption of other networked equipment in a condition providing networked standby into which the equipment is switched by the power management function, or a similar function, shall not exceed 3,00 W. The power consumption limits as stipulated in point (c) shall not apply to: (i) large format printing equipment; (ii) desktop thin clients; (iii) workstations; (iv) mobile workstations; (v) small-scale servers; (vi) computer servers.
for domestic drip filter coffee machines storing the coffee in an insulated jug, a maximum of five minutes after completion of the last brewing cycle or 30 minutes after completion of a descaling or self-cleaning process, for domestic drip filter coffee machines storing the coffee in a non-insulated jug, a maximum of 40 minutes after completion of the last brewing cycle, or 30 minutes after completion of a descaling or self-cleaning process, for domestic coffee machines other than drip filter coffee machines, a maximum of 30 minutes after completion of the last brewing cycle, or a maximum of 30 minutes after activation of the heating element, or a maximum of 60 minutes after activation of the cup preheating function, or a maximum of 30 minutes after completion of a descaling or self-cleaning process, unless an alarm has been triggered requiring users’ intervention to prevent possible damage or accident.
(a) for each standby and/or off mode and the condition providing networked standby into which the equipment is switched by the power management function or similar function: the power consumption data in Watt rounded to the first decimal place, the period of time after which the power management function, or a similar function, switches the equipment automatically into standby and/or off mode and/or the condition providing networked standby;
(b) the power consumption of the product in networked standby if all wired network ports are connected and all wireless network ports are activated; (c) guidance on how to activate and deactivate wireless network ports.
(a) for each standby and/or off mode: the power consumption data in Watt rounded to the first decimal place, the measurement method used, a description of how the equipment mode was selected or programmed, the sequence of events leading to the condition where the equipment automatically changes modes, any notes regarding the operation of the equipment, e.g. information on how the user switches the equipment into a condition having networked standby, if applicable, the default time after which the power management function, or similar function, has switched the equipment into the applicable low power mode or condition;
(b) for networked equipment: the number and type of network ports and, with the exception of wireless network ports, where these ports are located on the equipment; in particular it shall be declared if the same physical network port accommodates two or more types of network ports, whether all network ports are deactivated before delivery, whether the equipment qualifies as HiNA equipment or equipment with HiNa functionality; where no information is provided, this is considered not to be the case;
and for each type of network port: the default time after which the power management function, or a similar function, switches the equipment into a condition providing networked standby, the trigger that is used to reactivate the equipment, the (maximum) performance specifications, the (maximum) power consumption of the equipment in a condition providing networked standby into which the power management function, or a similar function, will switch the equipment, if only this port is used for remote activation, the communication protocol used by the equipment;
If no information is provided, the equipment is considered not to be networked equipment unless it provides the functionalities of a router, network switch, wireless network access point (not being a terminal), hub, modem, VoIP telephone, video phone. (c) test parameters for measurements: ambient temperature, test voltage in V and frequency in Hz, total harmonic distortion of the electricity supply system, information and documentation on the instrumentation, set-up and circuits used for electrical testing;
(d) the equipment characteristics relevant for assessing conformity with the requirements set out in point 1(c), or the requirements set out in points 2(c) and/or 2(d) and/or 3(b), as applicable, including the time taken to automatically reach standby, or off mode, or another condition which does not exceed the applicable power consumption requirements for off mode and/or standby mode. In particular, if applicable, a technical justification shall be provided that the requirements set out in point 1(c), or the requirements set out in points 2(c) and/or 2(d) and/or 3(b), are inappropriate for the intended use of equipment. The need to maintain one or more network connections or to wait for a remotely initiated trigger is not considered a technical justification for exemption from the requirements set out in 2(d) in the case of equipment that is not defined as networked equipment by the manufacturer.
(1) The Member State authorities shall verify one single unit of the model. (2) The model shall be considered to comply with the applicable requirements if: (a) the values given in the technical documentation pursuant to point 2 of Annex IV to Directive 2009/125/EC (declared values), and, where applicable, the values used to calculate these values, are not more favourable for the manufacturer or importer than the results of the corresponding measurements carried out pursuant to paragraph (g) thereof; and (b) the declared values meet any requirements laid down in this Regulation, and any required product information published by the manufacturer or importer does not contain values that are more favourable for the manufacturer or importer than the declared values; and (c) when the Member State authorities test the unit of the model, the determined values (the values of the relevant parameters as measured in testing and the values calculated from these measurements) comply with the respective verification tolerances as given in the table below.
(3) If the results referred to in point 2(a) or (b) are not achieved, the model shall be considered not to comply with this Regulation. (4) If the result referred to in point 2(c) is not achieved, the Member State authorities shall select three additional units of the same model for testing. (5) The model shall be considered to comply with the applicable requirements if, for these three units, the arithmetical mean of the determined values complies with the respective verification tolerances given in the table below. (6) If the result referred to in point 5 is not achieved, the model shall be considered not to comply with this Regulation. (7) The Member State authorities shall provide all relevant information to the authorities of the other Member States and to the Commission without delay after a decision being taken on the non-compliance of the model according to points 3 and 6.
Type of requirement | Category | Tolerance |
---|---|---|
Annex II, points 1(a) and (b), or points 2(a) and (b) | For power consumption requirements above 1,00 W | The determined value shall not exceed the declared value by more than 10 %. |
For power consumption requirements less than or equal to 1,00 W | The determined value shall not exceed the declared value by more than 0,10 W. | |
Annex II, points 3(c) and 4(a) | n/a | The determined value shall not exceed the declared value by more than 10 %. |