Commission Regulation (EU) 2019/1781 of 1 October 2019 laying down ecodesign requirements for electric motors and variable speed drives pursuant to Directive 2009/125/EC of the European Parliament and of the Council, amending Regulation (EC) No 641/2009 with regard to ecodesign requirements for glandless standalone circulators and glandless circulators integrated in products and repealing Commission Regulation (EC) No 640/2009 (Text with EEA relevance)
Modified by
- Commission Regulation (EU) 2021/341of 23 February 2021amending Regulations (EU) 2019/424, (EU) 2019/1781, (EU) 2019/2019, (EU) 2019/2020, (EU) 2019/2021, (EU) 2019/2022, (EU) 2019/2023 and (EU) 2019/2024 with regard to ecodesign requirements for servers and data storage products, electric motors and variable speed drives, refrigerating appliances, light sources and separate control gears, electronic displays, household dishwashers, household washing machines and household washer-dryers and refrigerating appliances with a direct sales function(Text with EEA relevance), 32021R0341, February 26, 2021
(1) This Regulation applies to the following products: (a) induction electric motors without brushes, commutators, slip rings or electrical connections to the rotor, rated for operation on a 50 Hz, 60 Hz or 50/60 Hz sinusoidal voltage, that: (i) have two, four, six or eight poles; (ii) have a rated voltage U N above 50 V and up to and including1000 V;(iii) have a rated power output P N from 0,12 kW up to and including1000 kW;(iv) are rated on the basis of continuous duty operation; and (v) are rated for direct on-line operation;
(b) variable speed drives with 3 phases input that: (i) are rated for operating with one motor refered to in point (a), within the 0,12 kW-1 000 kW motor rated output range; (ii) have a rated voltage above 100 V and up to and including 1000 V AC;(iii) have only one AC voltage output.
(2) The requirements in section 1, and points (1), (2), (5) to (11), and (13) of section 2 of Annex I shall not apply to the following motors: (a) motors completely integrated into a product (for example into a gear, pump, fan or compressor) and whose energy performance cannot be tested independently from the product, even with the provision of a temporary end-shield and drive-end bearing; the motor must share common components (apart from connectors such as bolts) with the driven unit (for example, a shaft or housing) and shall not be designed in such a way that the motor can be separated in its entirety from the driven unit and operate independently. The process of separation shall have the consequence of rendering the motor inoperative; (b) motors with an integrated variable speed drive (compact drives) whose energy performance cannot be tested independently from the variable speed drive; (c) motors with an integrated brake which forms an integral part of the inner motor construction and can neither be removed nor powered by a separate power source during the testing of the motor efficiency; (d) motors specifically designed and specified to operate exclusively: (i) at altitudes exceeding 4000 metres above sea-level;(ii) where ambient air temperatures exceed 60 °C; (iii) in maximum operating temperature above 400 °C; (iv) where ambient air temperatures are less than – 30 °C; or (v) where the water coolant temperature at the inlet to a product is below 0 °C or above 32 °C;
(e) motors specifically designed and specified to operate wholly immersed in a liquid; (f) motors specifically qualified for the safety of nuclear installations, as defined in Article 3 of Council Directive 2009/71/Euratom ;Council Directive 2009/71/Euratom of 25 June 2009 establishing a Community framework for the nuclear safety of nuclear installations ( OJ L 172, 2.7.2009, p. 18 ).(g) explosion-protected motors specifically designed and certified for mining, as defined in Annex I, point 1 of Directive 2014/34/EU of the European Parliament and of the Council ;Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres ( OJ L 96, 29.3.2014, p. 309 ).(h) motors in cordless or battery-operated equipment; (i) motors in hand-held equipment whose weight is supported by hand during operation; (j) motors in hand-guided mobile equipment moved while in operation; (k) motors with mechanical commutators; (l) Totally Enclosed Non-Ventilated (TENV) motors; (m) motors placed on the market before 1 July 2029 as substitutes for identical motors integrated in products placed on the market before1 July 2021 for motors referred to in Annex I.1 (a), and before1 July 2023 for motors referred to in Annex I.1 (b), and specifically marketed as such;(n) multi-speed motors, i.e. motors with multiple windings or with a switchable winding, providing a different number of poles and speeds; (o) motors designed specifically for the traction of electric vehicles.
(3) The requirements in section 3, and points (1), (2), and (5) to (10) of section 4 of Annex I shall not apply to the following VSDs: (a) VSDs integrated into a product and whose energy performance cannot be tested independently from the product, that is to say that an attempt to do so would render the VSD or the product inoperative; (b) VSDs qualified specifically for the safety of nuclear installations, as defined Article 3 of Directive 2009/71/Euratom; (c) regenerative drives; (d) drives with sinusoidal input current; (e) VSDs consisting of a single cabinet, comprising VSDs which are all in conformity with this Regulation.
(1) "electric motor" or "motor" means a device that converts electrical input power into mechanical output power in the form of a rotation with a rotational speed and torque that depends on factors including the frequency of the supply voltage and number of poles of the motor; (2) "variable speed drive" ("VSD") means an electronic power converter that continuously adapts the electrical power supplied to a single motor to control the motor’s mechanical power output according to the torque-speed characteristic of the load driven by the motor, by adjusting the power supply to a variable frequency and voltage supplied to the motor. It includes all protection devices and auxiliaries which are integrated in the VSD. (3) "energy efficiency" of a motor means the ratio of its mechanical output power to the electrical active input power; (4) "pole" means a north or a south pole produced by the rotating magnetic field of the motor, whose total number of poles determines its base speed; (5) "continuous duty operation" means capable of continuous operation at rated power with a temperature rise within the specified insulation temperature class, specified as specific duty types S1, S3 >=80 % or S6 >=80 % as defined in standards; (6) "phase" means the type of configuration of the mains; (7) "mains" or "electric mains" means the electricity supply from the grid; (8) "motor with mechanical commutators" means a motor in which a mechanical device reverses the direction of the current; (9) "cordless or battery operated equipment" means an appliance deriving its energy from batteries enabling the appliance to perform its intended function without a supply connection; (10) "hand-held equipment" means a portable appliance intended to be held in the hand during normal use; (11) "hand-guided equipment" means a non-road mobile appliance that is moved and guided by the user during normal use; (12) "totally enclosed non-ventilated (TENV) motor" means a motor designed and specified to operate without a fan, and which dissipates heat predominantly through natural ventilation or radiation on the totally enclosed motor surface; (13) "regenerative drive" means a VSD that is able to regenerate energy from the load to the mains, i.e. that induces a 180° +/- 20° phase shift of the input current to the input voltage when the load motor is braking; (14) "drive with sinusoidal input current" means a VSD with a sinusoidal waveform of the input current, characterised by a Total Harmonic Content below 10 %; (15) "brake motor" means a motor equipped with an electromechanical brake unit operating directly on the motor shaft without couplings; (16) "Ex eb increased safety motor" means a motor intended for use in explosive atmospheres and certified "Ex eb", as defined in standards; (17) "other explosion-protected motor" means a motor intended for use in explosive atmospheres and certified "Ex ec", "Ex tb", "Ex tc", "Ex db", or "Ex dc" as defined in standards; (18) "test load" of a VSD means the electrical device used for testing purposes that determines the output current and the output displacement factor cos phi; (19) "equivalent model" means a model which has the same technical characteristics relevant for the technical information to be provided, but which is placed on the market or put into service by the same manufacturer, importer or authorised representative as another model with a different model identifier; (20) "model identifier" means the code, usually alphanumeric, which distinguishes a specific product model from other models with the same trade mark or the same manufacturer’s, importer’s or authorised representative’s name; (21) "witnessed testing" means actively observing the physical testing of the product under investigation by another party, to draw conclusions on the validity of the test and the test results. This may include conclusions on the compliance of testing and calculations methods used with applicable standards and legislation; (22) "factory acceptance test" means a test on an ordered product where the customer uses witnessed testing to verify the product’s full accordance with contractual requirements, before they are accepted or put into service; (23) "declared values" means the values provided by the manufacturer, importer or authorised representative for the stated, calculated or measured technical parameters in accordance with Article 5, for the verification of compliance by the Member State authorities.
(a) from a model that has the same technical characteristics relevant for the technical information to be provided but is produced by a different manufacturer; or (b) by calculation on the basis of design or extrapolation from another model of the same or a different manufacturer, or both,
(1) setting additional resource efficiency requirements for products in accordance with the objectives of the circular economy, including identification and reuse of rare earth in permanent magnet motors; (2) the level of verification tolerances; (3) setting stricter requirements for motors and variable speed drives; (4) setting minimum energy efficiency requirements for motors with a rated voltage above 1000 V; (5) setting requirements for combinations of motors and VSDs placed on the market together, as well as integrated variable speed drives (compact drives); (6) the exemptions set out in Articles 2(2) and (3); (7) adding other types of motors to the scope, including permanent magnet motors.
(a) from 1 July 2021 :(i) the energy efficiency of three-phase motors with a rated output equal to or above 0,75 kW and equal to or below 1000 kW, with 2, 4, 6 or 8 poles, which are not Ex eb increased safety motors, shall correspond to at least the IE3 efficiency level set out in Table 2 or in Table 3b as appropriate;(ii) the energy efficiency of three-phase motors with a rated output equal to or above 0,12 kW and below 0,75 kW, with 2, 4, 6 or 8 poles, which are not Ex eb increased safety motors, shall correspond to at least the IE2 efficiency level set out in Table 1 or in Table 3a as appropriate;
(b) from 1 July 2023 :(i) the energy efficiency of Ex eb increased safety motors with a rated output equal to or above 0,12 kW and equal to or below 1000 kW, with 2, 4, 6 or 8 poles, and single-phase motors with a rated output equal to or above 0,12 kW shall correspond to at least the IE2 efficiency level set out in Table 1 or in Table 3a as appropriate;(ii) the energy efficiency of three-phase motors which are not brake motors, Ex eb increased safety motors, or other explosion-protected motors, with a rated output equal to or above 75 kW and equal to or below 200 kW, with 2, 4, or 6 poles, shall correspond to at least the IE4 efficiency level set out in Table 3 or in Table 3c as appropriate.
0,12 | 53,6 | 59,1 | 50,6 | 39,8 |
0,18 | 60,4 | 64,7 | 56,6 | 45,9 |
0,20 | 61,9 | 65,9 | 58,2 | 47,4 |
0,25 | 64,8 | 68,5 | 61,6 | 50,6 |
0,37 | 69,5 | 72,7 | 67,6 | 56,1 |
0,40 | 70,4 | 73,5 | 68,8 | 57,2 |
0,55 | 74,1 | 77,1 | 73,1 | 61,7 |
0,75 | 77,4 | 79,6 | 75,9 | 66,2 |
1,1 | 79,6 | 81,4 | 78,1 | 70,8 |
1,5 | 81,3 | 82,8 | 79,8 | 74,1 |
2,2 | 83,2 | 84,3 | 81,8 | 77,6 |
3 | 84,6 | 85,5 | 83,3 | 80,0 |
4 | 85,8 | 86,6 | 84,6 | 81,9 |
5,5 | 87,0 | 87,7 | 86,0 | 83,8 |
7,5 | 88,1 | 88,7 | 87,2 | 85,3 |
11 | 89,4 | 89,8 | 88,7 | 86,9 |
15 | 90,3 | 90,6 | 89,7 | 88,0 |
18,5 | 90,9 | 91,2 | 90,4 | 88,6 |
22 | 91,3 | 91,6 | 90,9 | 89,1 |
30 | 92,0 | 92,3 | 91,7 | 89,8 |
37 | 92,5 | 92,7 | 92,2 | 90,3 |
45 | 92,9 | 93,1 | 92,7 | 90,7 |
55 | 93,2 | 93,5 | 93,1 | 91,0 |
75 | 93,8 | 94,0 | 93,7 | 91,6 |
90 | 94,1 | 94,2 | 94,0 | 91,9 |
110 | 94,3 | 94,5 | 94,3 | 92,3 |
132 | 94,6 | 94,7 | 94,6 | 92,6 |
160 | 94,8 | 94,9 | 94,8 | 93,0 |
200 up to | 95,0 | 95,1 | 95,0 | 93,5 |
0,12 | 60,8 | 64,8 | 57,7 | 50,7 |
0,18 | 65,9 | 69,9 | 63,9 | 58,7 |
0,20 | 67,2 | 71,1 | 65,4 | 60,6 |
0,25 | 69,7 | 73,5 | 68,6 | 64,1 |
0,37 | 73,8 | 77,3 | 73,5 | 69,3 |
0,40 | 74,6 | 78,0 | 74,4 | 70,1 |
0,55 | 77,8 | 80,8 | 77,2 | 73,0 |
0,75 | 80,7 | 82,5 | 78,9 | 75,0 |
1,1 | 82,7 | 84,1 | 81,0 | 77,7 |
1,5 | 84,2 | 85,3 | 82,5 | 79,7 |
2,2 | 85,9 | 86,7 | 84,3 | 81,9 |
3 | 87,1 | 87,7 | 85,6 | 83,5 |
4 | 88,1 | 88,6 | 86,8 | 84,8 |
5,5 | 89,2 | 89,6 | 88,0 | 86,2 |
7,5 | 90,1 | 90,4 | 89,1 | 87,3 |
11 | 91,2 | 91,4 | 90,3 | 88,6 |
15 | 91,9 | 92,1 | 91,2 | 89,6 |
18,5 | 92,4 | 92,6 | 91,7 | 90,1 |
22 | 92,7 | 93,0 | 92,2 | 90,6 |
30 | 93,3 | 93,6 | 92,9 | 91,3 |
37 | 93,7 | 93,9 | 93,3 | 91,8 |
45 | 94,0 | 94,2 | 93,7 | 92,2 |
55 | 94,3 | 94,6 | 94,1 | 92,5 |
75 | 94,7 | 95,0 | 94,6 | 93,1 |
90 | 95,0 | 95,2 | 94,9 | 93,4 |
110 | 95,2 | 95,4 | 95,1 | 93,7 |
132 | 95,4 | 95,6 | 95,4 | 94,0 |
160 | 95,6 | 95,8 | 95,6 | 94,3 |
200 up to | 95,8 | 96,0 | 95,8 | 94,6 |
0,12 | 66,5 | 69,8 | 64,9 | 62,3 |
0,18 | 70,8 | 74,7 | 70,1 | 67,2 |
0,20 | 71,9 | 75,8 | 71,4 | 68,4 |
0,25 | 74,3 | 77,9 | 74,1 | 70,8 |
0,37 | 78,1 | 81,1 | 78,0 | 74,3 |
0,40 | 78,9 | 81,7 | 78,7 | 74,9 |
0,55 | 81,5 | 83,9 | 80,9 | 77,0 |
0,75 | 83,5 | 85,7 | 82,7 | 78,4 |
1,1 | 85,2 | 87,2 | 84,5 | 80,8 |
1,5 | 86,5 | 88,2 | 85,9 | 82,6 |
2,2 | 88,0 | 89,5 | 87,4 | 84,5 |
3 | 89,1 | 90,4 | 88,6 | 85,9 |
4 | 90,0 | 91,1 | 89,5 | 87,1 |
5,5 | 90,9 | 91,9 | 90,5 | 88,3 |
7,5 | 91,7 | 92,6 | 91,3 | 89,3 |
11 | 92,6 | 93,3 | 92,3 | 90,4 |
15 | 93,3 | 93,9 | 92,9 | 91,2 |
18,5 | 93,7 | 94,2 | 93,4 | 91,7 |
22 | 94,0 | 94,5 | 93,7 | 92,1 |
30 | 94,5 | 94,9 | 94,2 | 92,7 |
37 | 94,8 | 95,2 | 94,5 | 93,1 |
45 | 95,0 | 95,4 | 94,8 | 93,4 |
55 | 95,3 | 95,7 | 95,1 | 93,7 |
75 | 95,6 | 96,0 | 95,4 | 94,2 |
90 | 95,8 | 96,1 | 95,6 | 94,4 |
110 | 96,0 | 96,3 | 95,8 | 94,7 |
132 | 96,2 | 96,4 | 96,0 | 94,9 |
160 | 96,3 | 96,6 | 96,2 | 95,1 |
200 up to 249 | 96,5 | 96,7 | 96,3 | 95,4 |
250 up to 314 | 96,5 | 96,7 | 96,5 | 95,4 |
315 up to | 96,5 | 96,7 | 96,6 | 95,4 |
Rated output power P | Number of poles | |||
---|---|---|---|---|
2 | 4 | 6 | 8 | |
0,12 | 59,5 | 64,0 | 50,5 | 40,0 |
0,18 | 64,0 | 68,0 | 55,0 | 46,0 |
0,25 | 68,0 | 70,0 | 59,5 | 52,0 |
0,37 | 72,0 | 72,0 | 64,0 | 58,0 |
0,55 | 74,0 | 75,5 | 68,0 | 62,0 |
0,75 | 75,5 | 78,0 | 73,0 | 66,0 |
1,1 | 82,5 | 84,0 | 85,5 | 75,5 |
1,5 | 84,0 | 84,0 | 86,5 | 82,5 |
2,2 | 85,5 | 87,5 | 87,5 | 84,0 |
3,7 | 87,5 | 87,5 | 87,5 | 85,5 |
5,5 | 88,5 | 89,5 | 89,5 | 85,5 |
7,5 | 89,5 | 89,5 | 89,5 | 88,5 |
11 | 90,2 | 91,0 | 90,2 | 88,5 |
15 | 90,2 | 91,0 | 90,2 | 89,5 |
18,5 | 91,0 | 92,4 | 91,7 | 89,5 |
22 | 91,0 | 92,4 | 91,7 | 91,0 |
30 | 91,7 | 93,0 | 93,0 | 91,0 |
37 | 92,4 | 93,0 | 93,0 | 91,7 |
45 | 93,0 | 93,6 | 93,6 | 91,7 |
55 | 93,0 | 94,1 | 93,6 | 93,0 |
75 | 93,6 | 94,5 | 94,1 | 93,0 |
90 | 94,5 | 94,5 | 94,1 | 93,6 |
110 | 94,5 | 95,0 | 95,0 | 93,6 |
150 | 95,0 | 95,0 | 95,0 | 93,6 |
185 | 95,4 | 95,0 | 95,0 | 93,6 |
220 | 95,4 | 95,4 | 95,0 | 93,6 |
250 | 95,4 | 95,4 | 95,0 | 93,6 |
300 | 95,4 | 95,4 | 95,0 | 93,6 |
335 | 95,4 | 95,4 | 95,0 | 93,6 |
375 up to 1000 | 95,4 | 95,8 | 95,0 | 94,1 |
Rated output power P | Number of poles | |||
---|---|---|---|---|
2 | 4 | 6 | 8 | |
0,12 | 62,0 | 66,0 | 64,0 | 59,5 |
0,18 | 65,6 | 69,5 | 67,5 | 64,0 |
0,25 | 69,5 | 73,4 | 71,4 | 68,0 |
0,37 | 73,4 | 78,2 | 75,3 | 72,0 |
0,55 | 76,8 | 81,1 | 81,7 | 74,0 |
0,75 | 77,0 | 83,5 | 82,5 | 75,5 |
1,1 | 84,0 | 86,5 | 87,5 | 78,5 |
1,5 | 85,5 | 86,5 | 88,5 | 84,0 |
2,2 | 86,5 | 89,5 | 89,5 | 85,5 |
3,7 | 88,5 | 89,5 | 89,5 | 86,5 |
5,5 | 89,5 | 91,7 | 91,0 | 86,5 |
7,5 | 90,2 | 91,7 | 91,0 | 89,5 |
11 | 91,0 | 92,4 | 91,7 | 89,5 |
15 | 91,0 | 93,0 | 91,7 | 90,2 |
18,5 | 91,7 | 93,6 | 93,0 | 90,2 |
22 | 91,7 | 93,6 | 93,0 | 91,7 |
30 | 92,4 | 94,1 | 94,1 | 91,7 |
37 | 93,0 | 94,5 | 94,1 | 92,4 |
45 | 93,6 | 95,0 | 94,5 | 92,4 |
55 | 93,6 | 95,4 | 94,5 | 93,6 |
75 | 94,1 | 95,4 | 95,0 | 93,6 |
90 | 95,0 | 95,4 | 95,0 | 94,1 |
110 | 95,0 | 95,8 | 95,8 | 94,1 |
150 | 95,4 | 96,2 | 95,8 | 94,5 |
185 | 95,8 | 96,2 | 95,8 | 95,0 |
220 | 95,8 | 96,2 | 95,8 | 95,0 |
250 | 95,8 | 96,2 | 95,8 | 95,0 |
300 | 95,8 | 96,2 | 95,8 | 95,0 |
335 | 95,8 | 96,2 | 95,8 | 95,0 |
375 up to 1000 | 95,8 | 96,2 | 95,8 | 95,0 |
Rated output power P | Number of poles | |||
---|---|---|---|---|
2 | 4 | 6 | 8 | |
0,12 | 66,0 | 70,0 | 68,0 | 64,0 |
0,18 | 70,0 | 74,0 | 72,0 | 68,0 |
0,25 | 74,0 | 77,0 | 75,5 | 72,0 |
0,37 | 77,0 | 81,5 | 78,5 | 75,5 |
0,55 | 80,0 | 84,0 | 82,5 | 77,0 |
0,75 | 82,5 | 85,5 | 84,0 | 78,5 |
1,1 | 85,5 | 87,5 | 88,5 | 81,5 |
1,5 | 86,5 | 88,5 | 89,5 | 85,5 |
2,2 | 88,5 | 91,0 | 90,2 | 87,5 |
3,7 | 89,5 | 91,0 | 90,2 | 88,5 |
5,5 | 90,2 | 92,4 | 91,7 | 88,5 |
7,5 | 91,7 | 92,4 | 92,4 | 91,0 |
11 | 92,4 | 93,6 | 93,0 | 91,0 |
15 | 92,4 | 94,1 | 93,0 | 91,7 |
18,5 | 93,0 | 94,5 | 94,1 | 91,7 |
22 | 93,0 | 94,5 | 94,1 | 93,0 |
30 | 93,6 | 95,0 | 95,0 | 93,0 |
37 | 94,1 | 95,4 | 95,0 | 93,6 |
45 | 94,5 | 95,4 | 95,4 | 93,6 |
55 | 94,5 | 95,8 | 95,4 | 94,5 |
75 | 95,0 | 96,2 | 95,8 | 94,5 |
90 | 95,4 | 96,2 | 95,8 | 95,0 |
110 | 95,4 | 96,2 | 96,2 | 95,0 |
150 | 95,8 | 96,5 | 96,2 | 95,4 |
185 | 96,2 | 96,5 | 96,2 | 95,4 |
220 | 96,2 | 96,8 | 96,5 | 95,4 |
250 | 96,2 | 96,8 | 96,5 | 95,8 |
300 | 96,2 | 96,8 | 96,5 | 95,8 |
335 | 96,2 | 96,8 | 96,5 | 95,8 |
375 up to 1000 | 96,2 | 96,8 | 96,5 | 95,8 |
A | 22,4864 | 17,2751 | - | 6,4855 | |
B | 27,7603 | 23,978 | - | 9,4748 | |
C | 37,8091 | 35,5822 | 16,6861 | 36,852 | |
D | 82,458 | 84,9935 | 79,1838 | 70,762 | |
A | 6,8532 | 7,6356 | - | - | |
B | 6,2006 | 4,8236 | - | - | |
C | 25,1317 | 21,0903 | - | 4,2884 | |
D | 84,0392 | 86,0998 | 79,1318 | 75,831 | |
A | - | 8,432 | - | - | |
B | - | 2,6888 | - | - | |
C | 8,9002 | 14,6236 | - | 2,6653 | |
D | 85,0641 | 87,6153 | 82,0009 | 79,055 |
A | 0,2972 | 0,0278 | 0,0148 | 2,1311 | |
B | - | - | - | - | |
C | 13,0651 | 10,4395 | 13,247 | 26,719 | |
D | 79,077 | 80,9761 | 77,5603 | 69,735 | |
A | 0,3569 | 0,0773 | 0,1252 | 0,7189 | |
B | - | - | - | - | |
C | 11,6108 | 9,2984 | 11,9963 | 15,705 | |
D | 82,2503 | 83,7025 | 80,4769 | 77,074 | |
A | 0,34 | 0,2412 | 0,3598 | 0,6556 | |
B | - | - | - | - | |
C | 10,293 | 8,446 | 10,7933 | 13,977 | |
D | 84,8208 | 86,8321 | 84,107 | 80,247 |
(a) the technical data sheet or user manual supplied with the motor, unless an internet link to that information is supplied with the product. A QR code may in addition be supplied with a link to the information; (b) the technical documentation for the purposes of conformity assessment pursuant to Article 5; (c) free access websites of the manufacturer of the motor, its authorised representative or the importer, and; (d) the technical data sheet supplied with products in which the motor is incorporated.
(1) rated efficiency (η N ) at the full, 75 % and 50 % rated load, and rated voltage(s) (UN ), determined based on 25 °C ambient reference temperature, rounded to one decimal place;(2) efficiency level: "IE2" "IE3" or "IE4", as determined in the first section of this Annex; (3) manufacturer’s name or trade mark, commercial registration number and address; (4) product’s model identifier; (5) number of poles of the motor; (6) the rated power output(s) P N or range of rated power output (kW);(7) the rated input frequency(s) of the motor (Hz); (8) the rated voltage(s) or range of rated voltage (V); (9) the rated speed(s) or range of rated speed (rpm); (10) whether single-phase or three-phase; (11) information on the range of operating conditions for which the motor is designed: (a) altitudes above sea-level; (b) minimum and maximum ambient air temperatures including for motors with air cooling; (c) water coolant temperature at the inlet to the product, where applicable; (d) maximum operating temperature; (e) potentially explosive atmospheres;
(12) if the motor is considered exempt from efficiency requirement in accordance with Article 2(2) of this Regulation, the specific reason why it is considered exempt.
(13) The power losses expressed in percentage (%) of the rated output power at the following different operating points for speed versus torque: (25;25) (25;100) (50;25) (50;50) (50;100) (90;50) (90;100) determined based on 25 °C ambient reference temperature, rounded to one decimal place; if the motor is not suited for operation at any of the operating points for speed versus torque above, then "N.A." or "Not Applicable" should be indicated for such points.
Apparent output power of VSD (kVA) | Reference power losses (kW), at 90 % rated motor stator frequency and 100 % rated torque-producing current | ||
---|---|---|---|
0,278 | 0,12 | 0,100 | 0,73 |
0,381 | 0,18 | 0,104 | 0,73 |
0,500 | 0,25 | 0,109 | 0,73 |
0,697 | 0,37 | 0,117 | 0,73 |
0,977 | 0,55 | 0,129 | 0,73 |
1,29 | 0,75 | 0,142 | 0,79 |
1,71 | 1,1 | 0,163 | 0,79 |
2,29 | 1,5 | 0,188 | 0,79 |
3,3 | 2,2 | 0,237 | 0,79 |
4,44 | 3 | 0,299 | 0,79 |
5,85 | 4 | 0,374 | 0,79 |
7,94 | 5,5 | 0,477 | 0,85 |
9,95 | 7,5 | 0,581 | 0,85 |
14,4 | 11 | 0,781 | 0,85 |
19,5 | 15 | 1,01 | 0,85 |
23,9 | 18,5 | 1,21 | 0,85 |
28,3 | 22 | 1,41 | 0,85 |
38,2 | 30 | 1,86 | 0,85 |
47 | 37 | 2,25 | 0,85 |
56,9 | 45 | 2,70 | 0,86 |
68,4 | 55 | 3,24 | 0,86 |
92,8 | 75 | 4,35 | 0,86 |
111 | 90 | 5,17 | 0,86 |
135 | 110 | 5,55 | 0,86 |
162 | 132 | 6,65 | 0,86 |
196 | 160 | 8,02 | 0,86 |
245 | 200 | 10,0 | 0,87 |
302 | 250 | 12,4 | 0,87 |
381 | 315 | 15,6 | 0,87 |
429 | 355 | 17,5 | 0,87 |
483 | 400 | 19,8 | 0,87 |
604 | 500 | 24,7 | 0,87 |
677 | 560 | 27,6 | 0,87 |
761 | 630 | 31,1 | 0,87 |
858 | 710 | 35,0 | 0,87 |
967 | 800 | 39,4 | 0,87 |
900 | 44,3 | 0,87 | |
49,3 | 0,87 |
(a) the technical data sheet or user manual supplied with the VSD, unless an internet link to that information is supplied with the product. A QR code may in addition be supplied with a link to the information; (b) the technical documentation for the purposes of conformity assessment pursuant to Article 5; (c) free access websites of the manufacturer, its authorised representative or the importer and; (d) the technical data sheet supplied with products in which the VSD is incorporated.
(1) power losses in % of the rated apparent output power at the following different operating points for relative motor stator frequency versus relative torque-producing current (0;25) (0;50) (0;100) (50;25) (50;50) (50;100) (90;50) (90;100), as well as standby losses, generated when the VSD is powered up but is not providing current to the load, rounded to one decimal place; (2) efficiency level: "IE2" as determined in the third section of this annex; (3) manufacturer’s name or trade mark, commercial registration number and address; (4) product’s model identifier; (5) apparent output power or range of apparent output power (kVA); (6) indicative motor rated power output(s) P N or range of rated power output (kW);(7) rated output current (A); (8) maximum operating temperature (°C); (9) rated supply frequency(s) (Hz); (10) rated supply voltage(s) or range of rated supply voltage (V); (11) if the VSD is considered exempt from the efficiency requirements in accordance with Article 2(3) of this Regulation the specific reason why it is considered exempt.
Single-phase motors: Direct measurement: Input-Output; Three-phase motors: Summation of losses: Residual losses.
the input-output method; or the calorimetric method.
(1) The Member State authorities shall verify one single unit of the model. (2) The model shall be considered to comply with the applicable requirements if: (a) the values given in the technical documentation pursuant to point 2 of Annex IV to Directive 2009/125/EC (declared values) and where applicable the values used to calculate these values are not more favourable for the manufacturer, importer or authorised representative than the results of the corresponding measurements carried out pursuant to point (g) thereof; and (b) the declared values meet any requirements laid down in this Regulation and any required product information published by the manufacturer, importer or authorised representative does not contain values that are more favourable for the manufacturer, importer or authorised representative than the declared values; and (c) when the Member State authorities test the unit of the model, the determined values (the values of the relevant parameters as measured in testing and the values calculated from these measurements) comply with the respective verification tolerances as set out in Table 7.
(3) If the results referred to in points (2)(a) or (2)(b) are not achieved the model and all equivalent models shall be considered not to comply with this Regulation. (4) If the result referred to in point (2)(c) is not achieved; (a) for models that are produced in quantities of less than five per year including equivalent models, the model and all equivalent models shall be considered not to comply with this Regulation; (b) for models that are produced in quantities of five or more per year including equivalent models, the Member State authorities shall select three additional units of the same model for testing. As an alternative, the three additional units selected may be one or more of equivalent models.
(5) The model shall be considered to comply with the applicable requirements if for these three units the arithmetical mean of the determined values complies with the respective verification tolerances given in Table 7. (6) If the result referred to in point (5) is not achieved the model and all equivalent models shall be considered not to comply with this Regulation. (7) The Member State authorities shall provide all relevant information to the authorities of the other Member States and to the Commission without delay after a decision being taken on the non-compliance of the model according to points 3, 6 or the second paragraph of this Annex.
Total losses (1-η) for motors with a rated output equal to or above 0,12 kW and equal to or below 150 kW. | The determined value |
Total losses (1-η) for motors with a rated output of above 150 kW and equal to or below | The determined value |
Total losses for variable speed drives. | The determined value |
Loading ...