Number and item designation | Regulation SOLAS 74, as amended, and the relevant resolutions and circulars of the IMO, as applicable | Testing standards | Modules for conformity assessment | First placing on the market | Last placing on board |
---|
1 | 2 | 3 | 4 | 5 | 6 |
MED/3.1Primary decks covering | Type approval requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. II-2/6,
- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. II-2/6,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.2Portable fire extinguishers | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 4.
| - EN 3-7:2004 incl. A1:2007,
- EN 3-8:2006 incl. AC:2007,
- EN 3-9:2006 incl. AC:2007,
- EN 3-10:2009.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. II-2/18,
- SOLAS 74 Reg. II-2/19,
- SOLAS 74 Reg. II-2/20,
- IMO Res.A.951(23),
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 4.
- IMO MSC/Circ.1239,
- IMO MSC/Circ.1275.
|
MED/3.3Fire-fighter's outfit: protective clothing (close proximity clothing) | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 3.
| - Protective clothing for fire fighting:,
- EN 469:2005 incl. A1:2006 and AC:2006,
Or,- Protective clothing for fire fighting — Reflective clothing for specialised fire-fighting:,
- EN 1486:2007,
Or,- Protective clothing for fire fighting — Protective clothing with a reflective outer surface:,
- ISO 15538:2001.
Note: Level 2 | B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 3.
|
MED/3.4Fire-fighter's outfit: boots | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 3.
| - EN 15090:2012.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 3.
|
MED/3.5Fire-fighter's outfit: gloves | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 3.
| - EN 659:2003 incl. A1:2008 and AC:2009.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 3.
|
MED/3.6Fire-fighter's outfit: helmet | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 3.
| - EN 443:2008.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 3.
|
MED/3.7Self-contained compressed-air-operated breathing apparatusNote: For use in accidents involving dangerous goods a positive pressure type mask is required. | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 3.
| - EN 136:1998 incl. AC:2003,
- EN 137:2006,
And where the apparatus is for use in accidents with cargo:,- ISO 23269-3:2011.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 3.
And where the apparatus is for use in accidents with cargo:,- IMO Res.MSC.4(48)-(IBC Code) 14,
- IMO Res.MSC.5(48)-(IGC Code) 14.
|
MED/3.7Self-contained compressed-air-operated breathing apparatusNote: For use in accidents involving dangerous goods a positive pressure type mask is required. | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 3.
| - EN 136:1998 incl. AC:2003,
- EN 137:2006,
And where the apparatus is for use in accidents with cargo:,- ISO 23269-3:2011.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 3.
And where the apparatus is for use in accidents with cargo:,- IMO Res.MSC.4(48)-(IBC Code) 14,
- IMO Res.MSC.5(48)-(IGC Code) 14,
- IMO MSC.1/Circ.1499.
|
MED/3.8Compressed air line breathing apparatus | Type approval requirements- SOLAS 74 Reg. X/3,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- Note: This equipment is only for high speed craft built under provisions of the 1994 HSC Code.
| - EN 14593-1:2005,
- EN 14593-2:2005 incl. AC:2005
- EN 14594:2005 incl. AC:2005.
| B+DB+EB+F | | |
Carriage and performance requirements- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
|
MED/3.8Compressed air line breathing apparatus | Type approval requirements- SOLAS 74 Reg. X/3,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- Note: This equipment is only for high speed craft built under provisions of the 1994 HSC Code.
| - EN 14593-1:2005,
- EN 14594:2005 incl. AC:2005.
| B+DB+EB+F | | |
Carriage and performance requirements- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
|
MED/3.9Sprinkler systems components for accommodation spaces, service spaces and control stations equivalent to that referred to in SOLAS 74 Reg. II-2/12 (limited to nozzles and their performance).(Nozzles for fixed sprinkler systems, for high speed craft (HSC) are included under this item) | Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 8.
| - IMO Res. A.800(19),as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. II-2/9,
- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.44(65),
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 8.
- IMO MSC/Circ.912.
|
MED/3.10- Nozzles for fixed pressure water spraying fire extinguishing systems for machinery spaces and cargo pump-rooms
| Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 7.
| - IMO MSC/Circ.1165, Appendix A, as amended
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 7.
- IMO MSC.1/Circ.1313.
|
MED/3.11a"A" & "B" Class divisions fire integrity- (a)"A" class divisions,
| Type approval requirements- SOLAS 74 Reg. II-2/3.2.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended,
- IMO MSC.1/Circ.1435.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/3.2.
- SOLAS 74 Reg. II-2/9,
- IMO MSC/Circ.1120,
- IMO MSC.1/Circ.1434.
|
MED/3.11b"A" & "B" Class divisions fire integrity- (b)"B" class divisions.
| Type approval requirements- SOLAS 74 Reg. II-2/3.4.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/3.4.
- SOLAS 74 Reg. II-2/9.
|
MED/3.12Devices to prevent the passage of flame into the cargo tanks in tankers | Type approval requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. II-2/16.
| - P/V valves:,
- IMO MSC/Circ.677,
- ISO 15364:2007,
- Flame arresters, detonation flame arresters and high velocity valves:,
- IMO MSC/Circ.677,
- EN ISO 16852:2010.
| For equipment other than valves:- B+D
- B+E
- B+F
For valvesB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. II-2/16.
|
MED/3.12Devices to prevent the passage of flame into the cargo tanks in tankers | Type approval requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. II-2/16.
| - (a)P/V valves:
- IMO MSC/Circ.677, as amended,
- EN ISO 16852:2010,
- ISO 15364:2016.
- (b)Flame arresters:
- IMO MSC/Circ.677, as amended,
- EN ISO 16852:2010.
- (c)Detonation flame arresters:
- IMO MSC/Circ.677, as amended,
- EN ISO 16852:2010.
- (d)High velocity vent valves:
- IMO MSC/Circ.677, as amended,
- EN ISO 16852:2010,
- ISO 15364:2016.
| For equipment other than valves:- B+D
- B+E
- B+F
For valvesB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. II-2/16.
- IMO Res.MSC.98(73)-(FSS Code) 15.
|
MED/3.13Non-combustible materials | Type approval requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/5,
- SOLAS 74 Reg. II-2/9,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
Item MED/3.14, Materials other than steel for pipes penetrating "A" or "B" Class division, — included in MED/3.26 and MED/3.27. |
MED/3.15aMaterials other than steel for pipes conveying oil or fuel oil- (a)plastic pipes and fittings
| Type approval requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. X/3.
| Pipes and fittings:- IMO Res.A.753(18), as amended,
- IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/4,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 10,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 10,
- IMO MSC/Circ.1120.
|
MED/3.15bMaterials other than steel for pipes conveying oil or fuel oil- (b)valves
| Type approval requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. X/3.
| Valves:- EN ISO 10497:2010.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/4,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 10,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 10,
- IMO MSC/Circ.1120.
|
MED/3.15cMaterials other than steel for pipes conveying oil or fuel oil- (c)flexible pipe assemblies and compensators
| Type approval requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. X/3.
| Flexible pipe assemblies:- EN ISO 15540:2001,
- EN ISO 15541:2001.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/4,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 10,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 10,
- IMO MSC/Circ.1120.
|
MED/3.15dMaterials other than steel for pipes conveying oil or fuel oil- (d)metallic pipe components with resilient and elastomeric seals
| Type approval requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. X/3.
| Metallic pipe components with resilient and elastomeric seals:- ISO 19921:2005,
- ISO 19922:2005.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/4,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 10,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 10,
- IMO MSC/Circ.1120.
|
MED/3.16Fire Doors | Type approval requirements- SOLAS 74 Reg. II-2/9.
| - IMO Res.MSC.307(88)-(2010 FTP Code),
- IMO MSC.1/Circ.1319.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/9.
|
MED/3.16Fire Doors | Type approval requirements- SOLAS 74 Reg. II-2/9.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended,
- IMO MSC.1/Circ.1319.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/9,
- IMO MSC.1/Circ.1511.
|
MED/3.17Fire door control systems components.Note: When the term "system components" is used in column 2 it may be that a single component, a group of components or a whole system needs to be tested to ensure that the international requirements are fulfilled. | Type approval requirements- SOLAS 74 Reg. II-2/9,
- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/9,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.18aSurface materials and floor coverings with low flame-spread characteristics- (a)decorative veneers,
| Type approval requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/5,
- SOLAS 74 Reg. II-2/6,
- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/5,
- SOLAS 74 Reg. II-2/6,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO MSC/Circ.1120.
|
MED/3.18bSurface materials and floor coverings with low flame-spread characteristics- (b)paint systems,
| Type approval requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/5,
- SOLAS 74 Reg. II-2/6,
- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/5,
- SOLAS 74 Reg. II-2/6,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO MSC/Circ.1120.
|
MED/3.18cSurface materials and floor coverings with low flame-spread characteristics- (c)floor coverings.
| Type approval requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/5,
- SOLAS 74 Reg. II-2/6,
- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/5,
- SOLAS 74 Reg. II-2/6,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO MSC/Circ.1120.
|
MED/3.18dSurface materials and floor coverings with low flame-spread characteristics- (d)pipe insulation covers,
| Type approval requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/5,
- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/5,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO MSC/Circ.1120.
|
MED/3.18eSurface materials and floor coverings with low flame-spread characteristics- (e)adhesives used in the construction of "A", "B" & "C" class divisions,
| Type approval requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/5,
- SOLAS 74 Reg. II-2/9,
- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/5,
- SOLAS 74 Reg. II-2/9,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.18fSurface materials and floor coverings with low flame-spread characteristics- (f)combustible ducts membrane
| Type approval requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/5,
- SOLAS 74 Reg. II-2/9,
- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/5,
- SOLAS 74 Reg. II-2/9,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO MSC/Circ.1120.
|
MED/3.19Draperies, curtains and other suspended textile materials and films | Type approval requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/9,
- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
- IMO MSC.1/Circ.1456, as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/9,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.20- Upholstered furniture
| Type approval requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/5,
- SOLAS 74 Reg. II-2/9,
- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/5,
- SOLAS 74 Reg. II-2/9,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.21Bedding components | Type approval requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/9,
- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/3,
- SOLAS 74 Reg. II-2/9,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.22- Fire dampers
| Type approval requirements- SOLAS 74 Reg. II-2/9.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/9.
|
Item MED/3.23, Non combustible duct penetrations through "A" class divisions — Item deliberately left blank. |
Item MED/3.24, Electric cable transits through "A" class divisions — Item deliberately left blank. |
MED/3.25"A" and "B" class fire proof windows and side scuttles | Type approval requirements- SOLAS 74 Reg. II-2/9.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/9.
- IMO MSC/Circ.1120.
|
MED/3.26aPenetrations through "A" class divisions- (a)electric cable transits
| Type approval requirements- SOLAS 74 Reg. II-2/9.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | 12.1.2018(III) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/9.
|
MED/3.26aPenetrations through "A" class divisions- (a)electric cable transits
| Type approval requirements- SOLAS 74 Reg. II-2/9.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended,
- MSC.1/Circ. 1488.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/9.
|
MED/3.26bPenetrations through "A" class divisions- (b)pipe, duct, trunk, etc. penetrations
| Type approval requirements- SOLAS 74 Reg. II-2/9.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | 12.1.2018(III) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/9,
- IMO MSC.1/Circ. 1276.
|
MED/3.26bPenetrations through "A" class divisions- (b)pipe, duct, trunk, etc. penetrations
| Type approval requirements- SOLAS 74 Reg. II-2/9.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended,
- IMO MSC.1/Circ. 1488.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/9,
- IMO MSC.1/Circ. 1276.
|
MED/3.27aPenetrations through "B" class divisions- (a)electric cable transits,
| Type approval requirements- SOLAS 74 Reg. II-2/9.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/9.
|
MED/3.27bPenetrations through "B" class divisions- (b)pipe, duct, trunk, etc. penetrations.
| Type approval requirements- SOLAS 74 Reg. II-2/9.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/9.
|
MED/3.28Sprinkler systems (limited to sprinkler heads).(Nozzles for fixed sprinkler systems, for high speed craft (HSC) are included under this item) | Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3.
| - ISO 6182-1:2014.
Or,- EN 12259-1:1999 incl. A1:2001, A2:2004 and A3:2006.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.44(65),
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 8,
- IMO MSC/Circ.912.
|
MED/3.29Fire hoses with diameter ≤ 52 mm | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3.
| - EN 14540:2004 incl. A1:2007
| B+DB+EB+F | | 31.7.2017(II) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.29Fire-fighting hosesNon-percolating lay flat firefighting hoses (range of the inside diameter from 25 mm to 52 mm) | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3.
| - EN 14540:2014.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.30Portable oxygen analysis and gas detection equipment | Type approval requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. VI/3,
| - EN 60945 (2002) incl. IEC 60945 Corr. 1 (2008) or IEC 60945 (2002) incl. IEC 60945 Corr. 1 (2008),
- IEC 60092-504:2001 incl. IEC 60092-504 Corr.1: 2011,
- IEC 60533:1999,
And as applicable to:- (a)Category 1: (safe area):
- EN 50104:2010,
- EN 60079-29-1:2007,
- (b)Category 2: (explosive gas atmospheres):,
- EN 50104:2010,
- EN 60079-29-1:2007,
- EN 60079-0:2012 incl. A11:2013,
- EN 60079-1:2007 incl. IEC 60079-1 Corrigendum 1 (2008),
- EN 60079-10-1:2009,
- EN 60079-11:2012,
- EN 60079-15:2010,
- EN 60079-26:2007.
| B+DB+EB+F | | 1.6.2019(II) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. VI/3,
- IMO Res.MSC.98(73)-(FSS Code) 15.
|
MED/3.30Portable oxygen analysis and gas detection equipment | Type approval requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. VI/3,
- SOLAS 74 Reg. XI-1/7.
| - EN 60945:2002 incl. IEC 60945 Corr. 1:2008, or IEC 60945 (2002) incl. IEC 60945 Corr. 1 (2008),
- IEC 60092-504:2016,
- IEC 60533:2015,
And as applicable to:- (a)Category 1: (safe area):
- EN 50104:2010,
- EN 60079-29-1:2007,
- (b)Category 2: (explosive gas atmospheres):,
- EN 50104:2010,
- EN 60079-29-1:2007,
- EN 60079-0:2012 incl. A11:2013,
- EN 60079-1:2014,
- EN 60079-10-1:2015,
- EN 60079-11:2012,
- EN 60079-15:2010,
- EN 60079-26:2015.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. VI/3,
- SOLAS 74 Reg. XI-1/7.
- IMO Res.MSC.98(73)-(FSS Code) 15,
- IMO MSC..1/Circ.1477.
|
Item MED/3.31, Nozzles for fixed sprinkler systems for high speed craft ((HSC), deleted as it is covered by MED/3.9 and MED/3.28. |
MED/3.32Fire restricting materials (except furniture) for high speed craft | Type approval requirements- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO MSC.1/Circ.1457.
|
MED/3.33Fire restricting materials for furniture for high speed craft | Type approval requirements- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.34Fire resisting divisions for high speed craft | Type approval requirements- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO MSC.1/Circ.1457.
|
MED/3.35Fire doors on high speed craft | Type approval requirements- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.36Fire dampers on high speed craft | Type approval requirements- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.37aPenetrations through fire resisting divisions on high speed craft- (a)electric cable transits,
| Type approval requirements- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.37bPenetrations through fire resisting divisions on high speed craft- (b)pipe, duct, trunk etc. penetrations.
| Type approval requirements- SOLAS 74 Reg. X/3.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.38- Portable fire-extinguishing equipment for lifeboats and rescue boats
| Type approval requirements- SOLAS 74 Reg. III/4,
- SOLAS 74 Reg. X/3.
| - EN 3-7:2004 incl. A1:2007,
- EN 3-8:2006 incl. AC:2007,
- EN 3-9:2006 incl. AC:2007,
- EN 3-10:2009.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. III/34,
- IMO Res.A.951(23),
- IMO Res.MSC.36(63)-(1994 HSC Code) 8,
- IMO Res.MSC.48(66)-(LSA Code) I,
- IMO Res.MSC.48(66)-(LSA Code) IV,
- IMO Res.MSC.48(66)-(LSA Code) V,
- IMO Res.MSC.97(73)-(2000 HSC Code) 8.
|
MED/3.39Nozzles for equivalent water-mist fire extinguishing systems for machinery spaces and cargo pump rooms | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 7.
| - IMO MSC/Circ.1165, as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 7.
- IMO MSC.1/Circ.1313,
- IMO MSC.1/Circ.1458.
|
MED/3.40Low-location lighting systems (components only) | Type approval requirements- SOLAS 74 Reg. II-2/13,
- IMO Res.MSC.98(73)-(FSS Code) 11.
| - IMO Res.A.752(18),
- ISO 15370:2010.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/13,
- IMO Res.A.752(18),
- IMO Res.MSC.98(73)-(FSS Code) 11.
|
MED/3.41Emergency escape breathing devices (EEBD) | Type approval requirements- SOLAS 74 Reg. II-2/13.
| - ISO 23269-1:2008,
and alternatively:- For self-contained: open-circuit compressed air breathing apparatus with full mask or mouthed piece assembly for escape:,
- EN 402:2003;
- For self-contained open-circuit compressed air breathing apparatus with a hood for escape:,
- EN 1146:2005;
- For self-contained: closed-circuit compressed air breathing apparatus:,
- EN 13794:2002.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/13.
- IMO Res.MSC.98(73)-(FSS Code) 3,
- IMO MSC/Circ.849.
|
MED/3.42Inert gas systems components | Type approval requirements- SOLAS 74 Reg. II-2/4.
| - IMO MSC/Circ.353, as amended.
| B+DB+EB+FG | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/4.
- IMO Res.A.567(14),
- IMO Res.MSC.98(73)-(FSS Code) 15,
- IMO MSC/Circ.353,
- IMO MSC/Circ.485,
- IMO MSC/Circ.731,
- IMO MSC/Circ.1120.
|
MED/3.43Nozzles for deep fat cooking equipment fire extinguishing systems (automatic or manual type). | Type approval requirements- SOLAS 74 Reg. II-2/1,
- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3.
| - ISO 15371:2009.
| B+DB+EB+F | | 15.11.2018(III) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/1,
- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO MSC.1/Circ.1433.
|
MED/3.43Nozzles for deep fat cooking equipment fire extinguishing systems (automatic or manual type). | Type approval requirements- SOLAS 74 Reg. II-2/1,
- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3.
| - ISO 15371:2015.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/1,
- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO MSC.1/Circ.1433.
|
MED/3.44Fire-fighters outfit — lifeline | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 3.
| - IMO Res.MSC.98(73)-(FSS Code) 3, as amended,
- IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 3.
|
MED/3.45Equivalent fixed gas fire extinguishing systems components (extinguishing medium, head valves and nozzles) for machinery spaces and cargo pump rooms | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 5.
| - IMO MSC/Circ.848, as amended,
- IMO MSC.1/Circ.1316.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 5.
- IMO MSC/Circ.848,
- IMO MSC.1/Circ.1313,
- IMO MSC.1/Circ.1316.
|
MED/3.46Equivalent fixed gas fire extinguishing systems for machinery spaces (aerosol systems) | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 5.
| - IMO MSC/Circ.1270 incl. Corr.1, as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 5.
- IMO MSC/Circ.1270 incl. Corr.1,
- IMO MSC.1/Circ.1313.
|
MED/3.47Concentrate for fixed high expansion foam fire extinguishing systems for machinery spaces and cargo pump rooms.Note: The fixed high expansion foam fire extinguishing system (including those systems which use inside air from their working spaces for their intended performance), for machinery spaces and cargo pump rooms must still be tested with the approved concentrate to the satisfaction of the administration. | Type approval requirements- SOLAS 74 Reg. II-2/10.
| - IMO MSC/Circ.670.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10.
- IMO Res.MSC.98(73)-(FSS Code) 6.
|
MED/3.48Fixed water based local application fire-fighting systems components for use in category A machinery spaces(Nozzles and performance tests). | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3.
| - IMO MSC.1/Circ.1387.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.49aFixed water-based fire-fighting systems for roro spaces, vehicle spaces and special category spaces- (a)Prescriptive-based systems as per Circ.1430 Clause 4.
| Type approval requirements- SOLAS 74 Reg. II-2/19,
- SOLAS 74 Reg. II-2/20,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 7.
| - IMO MSC.1/Circ.1430.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/19,
- SOLAS 74 Reg. II-2/20,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 7.
|
MED/3.49bFixed waterbased firefighting systems for roro spaces, vehicle spaces and special category spaces- (b)Performance-based systems as per Circ. 1430 Clause 5.
| Type approval requirements- SOLAS 74 Reg. II-2/19,
- SOLAS 74 Reg. II-2/20,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 7.
| - IMO MSC.1/Circ.1430.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/19,
- SOLAS 74 Reg. II-2/20,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 7.
|
Item MED/3.50, Protective clothing resistant to chemical attack — Item deliberately left blank. |
MED/3.51aFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (a)Control and indicating equipment
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Control and indicating equipment. Electrical installations in ships:
- EN 54-2:1997 incl. AC:1999 and A1:2006.
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2001 incl. IEC 60092-504 Corr.1: 2011,
- IEC 60533:1999.
| B+DB+EB+F | | 1.6.2019(III) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.51aFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (a)Control and indicating equipment
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Control and indicating equipment. Electrical installations in ships:
- EN 54-2:1997 incl. AC:1999 and A1:2006.
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2016,
- IEC 60533:2015.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242,
- IMO MSC.1/Circ.1487.
|
MED/3.51bFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (b)Power supply equipment,
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Power supply equipment:
- EN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006.
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2001 incl. IEC 60092-504 Corr.1: 2011,
- IEC 60533:1999.
| B+DB+EB+F | | 1.6.2019(III) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.51bFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (b)Power supply equipment,
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Power supply equipment:
- EN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006.
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2016,
- IEC 60533:2015.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.51cFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (c)Heat detectors — Point detectors,
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Heat detectors — Point detectors:
- EN 54-5:2000 incl. A1:2002.
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2001 incl. IEC 60092-504 Corr.1: 2011,
- IEC 60533:1999.
| B+DB+EB+F | | 1.6.2019(III) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.51cFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (c)Heat detectors — Point detectors,
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Heat detectors — Point detectors:
- EN 54-5:2000 incl. A1:2002.
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2016,
- IEC 60533:2015.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.51dFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (d)Smoke detectors: Point detectors using scattered light, transmitted light or ionization,
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Smoke detectors — Point detectors using scattered light, transmitted light or ionisation:
- EN 54-7:2000 incl. A1:2002 and A2:2006.
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2001 incl. IEC 60092-504 Corr.1: 2011,
- IEC 60533:1999.
| B+DB+EB+F | | 1.6.2019(III) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.51dFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (d)Smoke detectors: Point detectors using scattered light, transmitted light or ionization,
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Smoke detectors — Point detectors using scattered light, transmitted light or ionisation:,
- EN 54-7:2015.
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2016,
- IEC 60533:2015.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.51eFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (e)Flame detectors: Point detectors,
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Flame detectors — Point detectors:
- EN 54-10:2002 incl. A1:2005.
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2001 incl. IEC 60092-504 Corr.1: 2011,
- IEC 60533:1999.
| B+DB+EB+F | | 1.6.2019(III) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.51eFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (e)Flame detectors: Point detectors,
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Flame detectors — Point detectors:,
- EN 54-10:2002 incl. A1:2005,
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2016,
- IEC 60533:2015.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.51fFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (f)Manual call points,
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Manual call points:
- EN 54-11:2001 incl. A1:2005.
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2001 incl. IEC 60092-504 Corr.1: 2011,
- IEC 60533:1999.
| B+DB+EB+F | | 1.6.2019(III) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.51fFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (f)Manual call points,
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Manual call points:
- EN 54-11:2001 incl. A1:2005.
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2016,
- IEC 60533:2015.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.51 gFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (g)Short circuit isolators,
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Short circuit isolators:
- EN 54-17:2007 incl. AC:2007.
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2001 incl. IEC 60092-504 Corr.1: 2011,
- IEC 60533:1999.
| B+DB+EB+F | | 1.6.2019(III) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.51 gFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (g)Short circuit isolators,
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Short circuit isolators:
- EN 54-17:2007 incl. AC:2007.
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2016,
- IEC 60533:2015.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.51 hFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (h)Input/output devices,
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Input/output devices:
- EN 54-18 (2005) including AC(2007).
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2001 incl. IEC 60092-504 Corr.1: 2011,
- IEC 60533:1999.
| B+DB+EB+F | | 1.6.2019(III) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.51 hFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (h)Input/output devices,
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Input/output devices:
- EN 54-18:2005 incl. AC:2007.
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2016,
- IEC 60533:2015.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.51iFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (i)Cables.
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Cables:,
- EN 60332-1-2:2004,
- IEC 60092-376:2003,
And, as applicable, electrical and electronic installations in ships:,- IEC 60092-504:2001 incl. IEC 60092-504 Corr.1: 2011,
- IEC 60533:1999.
| B+DB+EB+F | | 1.6.2019(III) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.51iFixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces:- (i)Cables.
| Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| - Cables:
- EN 60332-1-2:2004,
- IEC 60092-376:2003.
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2016,
- IEC 60533:2015.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.52Non-portable and transportable fire extinguishers | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3.
| - EN 1866-1:2007,-
- EN 1866-3:2013,
Or,- ISO 11601:2008.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.52Non-portable and transportable fire extinguishers | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3.
| - EN 1866-1:2007,
- EN 1866-2:2014.
Or,- EN 1866-1:2007,
- EN 1866-3:2013.
Or,- ISO 11601:2008.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.53Fire alarm devices — Sounders | Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| Sounders:- EN 54-3:2001 incl. A1:2002 and A2:2006,
- IEC 60092-504:2001 incl. IEC 60092-504 Corr.1: 2011,
- IEC 60533:1999.
| B+DB+EB+F | | 1.6.2019(III) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242.
|
MED/3.53Fire alarm devices — Sounders | Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. X/3,
- IMO Res.MSC.98(73)-(FSS Code) 9.
| Sounders:- EN 54-3:2014,
- IEC 60092-504:2016,
- IEC 60533:2015.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7,
- IMO Res.MSC.98(73)-(FSS Code) 9.
- IMO MSC.1/Circ.1242,
- IMO MSC.1/Circ.1487.
|
MED/3.54Fixed oxygen analysis and gas detection equipment | Type approval requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. VI/3.
| - IEC 60092-504:2001 incl. IEC 60092-504 Corr.1: 2011,
- IEC 60533:1999.
And, as applicable, to:- (a)Category 4: (safe area),
- EN 50104:2010;
- (b)Category 3: (explosive gas atmospheres),
- EN 50104:2010,
- EN 60079-0:2012 incl. A11:2013,
- EN 60079-29-1:2007.
For combined O2/HC systems, additionally:- IMO MSC.1/Circ.1370.
| B+DB+EB+F | | 1.6.2019(III) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. VI/3.
- IMO Res.MSC.98(73)-(FSS Code) 15,
- for combined O2/HC systems additionally:,
- IMO MSC.1/Circ.1370.
|
MED/3.54Fixed oxygen analysis and gas detection equipment | Type approval requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. VI/3.
| - IEC 60092-504:2016,
- IEC 60533:2015.
And as applicable to:- (a)Category 4: (safe area),
- EN 50104:2010,
- (b)Category 3: (explosive gas atmospheres),
- EN 50104:2010,
- EN 60079-0:2012 incl. A11:2013,
- EN 60079-29-1:2007.
For combined O2/HC systems, additionally:- IMO MSC.1/Circ.1370.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/4,
- SOLAS 74 Reg. VI/3.
- IMO Res.MSC.98(73)-(FSS Code) 15,
- for combined O2/HC systems additionally:,
- IMO MSC.1/Circ.1370.
|
MED/3.55Dual purpose type nozzles (spray/jet type) | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3.
| - Hand-held branchpipes for fire service use — Combination branchpipes PN 16:,
- EN 15182-1:2007 incl. A1:2009,
- EN 15182-2:2007 incl. A1:2009,
- Hand-held branchpipes for fire service use — Smooth bore jet and/or one fixed spray jet angle branchpipes PN 16:,
- EN 15182-1:2007 incl. A1:2009.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.55Dual purpose type nozzles (spray/jet type) | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3.
| - Hand-held branchpipes for fire service use — Combination branchpipes PN 16:,
- EN 15182-1:2007 incl. A1:2009,
- EN 15182-2:2007 incl. A1:2009,
- Hand-held branchpipes for fire service use — Smooth bore jet and/or one fixed spray jet angle branchpipes PN 16:,
- EN 15182-1:2007 incl. A1:2009,
- EN 15182-3:2007 incl. A1:2009.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.56Fixed firefighting hose systemsHose reels with semi-rigid hose | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3.
| - EN 671-1:2012
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.57Medium Expansion Foam Fire Extinguishing Systems components — Fixed Deck Foam for Tankers | Type approval requirements- SOLAS 74 Reg. II-2/10.
| - IMO MSC/Circ.798.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10.8.1,
- IMO Res.MSC.98(73)-(FSS Code) 14,
- IMO MSC/Circ.1239,
- IMO MSC.1/Circ.1276.
|
MED/3.58Fixed Low Expansion Foam Fire Extinguishing Systems Components for Machinery Spaces and Tanker Deck Protection. | Type approval requirements- SOLAS 74 Reg. II-2/10.
| - IMO MSC.1/Circ.1312,
- IMO MSC.1/Circ.1312/Corr.1.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10.
- IMO Res.MSC.98(73)-(FSS Code) 6,
- IMO Res.MSC.98(73)-(FSS Code) 14,
- IMO MSC/Circ.1239,
- IMO MSC.1/Circ.1276.
|
MED/3.59Expansion Foam for Fixed Fire Extinguishing Systems for Chemical Tankers | Type approval requirements- SOLAS 74 Reg. II-2/1,
- IMO Res.MSC.4(48)-(IBC Code) 11.
| - IMO MSC.1/Circ.1312,
- IMO MSC.1/Circ.1312/Corr.1.
| B+DB+EB+F | | |
Carriage and performance requirements- IMO Res.MSC.4(48)-(IBC Code) 11.
- IMO MSC/Circ.553.
|
MED/3.60- Nozzles for fixed pressure water-spraying fire-extinguishing systems for cabin balconies
| Type approval requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.98(73)-(FSS Code) 7.
| - IMO MSC.1/Circ.1268.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.98(73)-(FSS Code) 7.
- IMO MSC.1/Circ.1313.
|
MED/3.61a- (a)Inside air high expansion foam systems for the protection of machinery spaces, cargo pump rooms, vehicle and ro-ro spaces, special category spaces and cargo spaces.
Note: Inside/Outside air high expansion foam systems for the protection of machinery spaces, cargo pump rooms, vehicle and ro-ro spaces, special category spaces and cargo spaces shall be tested with the approved concentrate to the satisfaction of the Administration | Type approval requirements- SOLAS 74 Reg. II-2/10.
| - IMO MSC.1/Circ.1384.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10.
- IMO Res.MSC.98(73)-(FSS Code) 6.
|
MED/3.61b- (b)Outside air high expansion foam systems for the protection of machinery spaces, cargo pump rooms, vehicle and ro-ro spaces, special category spaces and cargo spaces.
Note: Inside/Outside air high expansion foam systems for the protection of machinery spaces, cargo pump rooms, vehicle and ro-ro spaces, special category spaces and cargo spaces shall be tested with the approved concentrate to the satisfaction of the Administration | Type approval requirements- SOLAS 74 Reg. II-2/10.
| - IMO MSC.1/Circ.1384.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10.
- IMO Res.MSC.98(73)-(FSS Code) 6.
|
MED/3.62Dry chemical powder extinguishing systems | Type approval requirements- SOLAS 74 Reg. II-2/1.
| - IMO MSC.1/Circ.1315.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/1.
- IMO Res.MSC.5(48)-(IGC Code) 11.
|
MED/3.63Sample extraction smoke detection systems components | Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. II-2/19,
- SOLAS 74 Reg. II-2/20.
| - IMO Res.MSC.98(73)-(FSS Code) 10.
And for:- Control and indicating equipment. Electrical installations in ships:
- EN 54-2:1997 incl. AC:1999 and A1:2006;
- Power supply equipment:
- EN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006;
- Aspiring smoke detectors:
- EN 54-20:2006 incl. AC:2008.
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2001 incl. IEC 60092-504 Corr.1: 2011,
- IEC 60533:1999.
And, as applicable for explosive atmospheres:- EN 60079-0:2012 incl. A11:2013.
| B+DB+EB+F | | 1.6.2019(III) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. II-2/19,
- SOLAS 74 Reg. II-2/20.
- IMO Res.MSC.98(73)-(FSS Code) 10.
|
MED/3.63Sample extraction smoke detection systems components | Type approval requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. II-2/19,
- SOLAS 74 Reg. II-2/20.
| - IMO Res.MSC.98(73)-(FSS Code) 10.
And for:- Control and indicating equipment. Electrical installations in ships:
- EN 54-2:1997 incl. AC:1999 and A1:2006;
- Power supply equipment:
- EN 54-4:1997 incl. AC:1999, A1:2002 and A2:2006;
- Aspiring smoke detectors:
- EN 54-20:2006 incl. AC:2008.
And, as applicable, electrical and electronic installations in ships:- IEC 60092-504:2016
- IEC 60533:2015
And, as applicable for explosive atmospheres:- EN 60079-0:2012 incl. A11:2013.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/7,
- SOLAS 74 Reg. II-2/19,
- SOLAS 74 Reg. II-2/20.
- IMO Res.MSC.98(73)-(FSS Code) 10.
|
MED/3.64C class divisions | Type approval requirements- SOLAS 74 Reg. II-2/3.10.
| - IMO Res.MSC.307(88)-(2010 FTP Code), as amended.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/3.10.
- SOLAS 74 Reg. II-2/9.
|
MED/3.65Fixed hydrocarbon gas detection system | Type approval requirements- SOLAS 74 Reg. II-2/4.
| - IMO MSC.1/Circ.1370,
- EN 60079-0:2012 incl. A11:2013,
- EN 60079-29-1:2007,
- IEC 60092-504:2001 incl. IEC 60092-504 Corr.1: 2011,
- IEC 60533:1999.
| B+DB+EB+F | | 1.6.2019(III) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/4.
- IMO Res.MSC.98(73)-(FSS Code) 16,
- IMO MSC.1/Circ.1370.
|
MED/3.65Fixed hydrocarbon gas detection system | Type approval requirements- SOLAS 74 Reg. II-2/4.
| - IMO MSC.1/Circ.1370,
- EN 60079-0:2012 incl. A11:2013,
- EN 60079-29-1:2007,
- IEC 60092-504:2016,
- IEC 60533:2015.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/4.
- IMO Res.MSC.98(73)-(FSS Code) 16,
- IMO MSC.1/Circ.1370.
|
MED/3.66Evacuation guidance systems used as an alternative to low-location lighting systems | Type approval requirements- SOLAS 74 Reg. II-2/13.
| - IMO MSC.1/Circ.1168.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/13.
- IMO MSC.1/Circ.1168.
|
MED/3.67Helicopter facility foam fire-fighting appliances | Type approval requirements- SOLAS 74 Reg. II-2/18.
| - EN 13565-1:2003 incl. A1:2007.
| B+DB+EB+F | | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/18.
- IMO MSC.1/Circ.1431.
|
MED/3.68Galley Exhaust Duct Fixed Fire Extinguishing Systems components | Type approval requirements- SOLAS 74 Reg. II-2/9.
| - ISO 15371:2009.
| B+DB+EB+F | | 30.4.2018(III) |
Carriage and performance requirements- SOLAS 74 Reg. II-2/9.
|
MED/3.68Galley Exhaust Duct Fixed Fire Extinguishing Systems components | Type approval requirements- SOLAS 74 Reg. II-2/9.
| - ISO 15371:2015.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/9.
|
MED/3.69Mobile water monitor for ships constructed on or after 1 January 2016 designed to carry five or more tiers of containers on or above the weather deck(new item) | Type approval requirements- SOLAS 74 Reg.II-2/10.
| - MSC.1/Circ.1472.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg.II-2/10.
- MSC.1/Circ.1472.
|
MED/3.70Fire-fighting hosesSemi-rigid hoses for fixed systems(new item) | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3.
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
| - EN 694 (2014).
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,
- IMO Res.MSC.97(73)-(2000 HSC Code) 7.
|
MED/3.71Fixed firefighting hose systemsHose systems with lay-flat hose(new item) | Type approval requirements- SOLAS 74 Reg. II-2/10,
- SOLAS 74 Reg. X/3.
| - EN 671-2:2012.
| B+DB+EB+F | 16.3.2017 | |
Carriage and performance requirements- SOLAS 74 Reg. II-2/10,
- IMO Res.MSC.36(63)-(1994 HSC Code) 7,