(a) appliances that use energy sources other than electricity or gas; (b) appliances which offer "microwave heating" function; (c) small ovens; (d) portable ovens; (e) heat storage ovens; (f) ovens which are heated with steam as a primary heating function; (g) covered gas burners in hobs; (h) outdoor cooking appliances; (i) appliances designed for use only with gases of the "third family" (propane and butane); (j) grills.
Commission Regulation (EU) No 66/2014 of 14 January 2014 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for domestic ovens, hobs and range hoods Text with EEA relevance
Modified by
- Commission Regulation (EU) 2016/2282of 30 November 2016amending Regulations (EC) No 1275/2008, (EC) No 107/2009, (EC) No 278/2009, (EC) No 640/2009, (EC) No 641/2009, (EC) No 642/2009, (EC) No 643/2009, (EU) No 1015/2010, (EU) No 1016/2010, (EU) No 327/2011, (EU) No 206/2012, (EU) No 547/2012, (EU) No 932/2012, (EU) No 617/2013, (EU) No 666/2013, (EU) No 813/2013, (EU) No 814/2013, (EU) No 66/2014, (EU) No 548/2014, (EU) No 1253/2014, (EU) 2015/1095, (EU) 2015/1185, (EU) 2015/1188, (EU) 2015/1189 and (EU) 2016/2281 with regard to the use of tolerances in verification procedures(Text with EEA relevance), 32016R2282, December 20, 2016
(1) "oven" means an appliance or part of an appliance which incorporates one or more cavities using electricity and/or gas in which food is prepared by use of a conventional or fan-forced mode; (2) "cavity" means the enclosed compartment in which the temperature can be controlled for preparation of food; (3) "multi-cavity oven" means an oven with two or more cavities, each of which is heated separately; (4) "small oven" means an oven where all cavities have a width and depth of less than 250 mm or a height less than 120 mm; (5) "portable oven" means an oven with a product mass of less than 18 kilograms, provided it is not designed for built-in installations; (6) "microwave heating" means heating of food using electromagnetic energy; (7) "conventional mode" means the operation mode of an oven only using natural convection for circulation of heated air inside the cavity of the oven; (8) "fan-forced mode" means a mode when a built-in fan circulates heated air inside the cavity of the oven; (9) "cycle" means the period of heating a standardised load in a cavity of an oven under defined conditions; (10) "cooker" means an appliance consisting of an oven and a hob using gas or electricity; (11) "operation mode" means the status of the oven or hob during use; (12) "heat source" means the main energy form for heating an oven or hob; (13) "electric hob" means an appliance or part of an appliance which incorporates one or more cooking zones and/or cooking areas including a control unit and which is heated by electricity; (14) "gas hob" means an appliance or part of an appliance which incorporates one or more cooking zones including a control unit and which is heated by gas burners of a minimum power of 1,16 kW; (15) "hob" means an "electric hob", a "gas hob" or a "mixed hob"; (16) "covered gas burners" means closed or sealed gas range burners covered with a heavy-duty glass or ceramic cover, which forms a smooth, seamless cooking surface; (17) "mixed hob" means an appliance with one or more electrically heated cooking zones or areas and one or more cooking zones heated by gas burners; (18) "cooking zone" means a part, with a diameter of at least 100 mm, of a hob where cookware is placed and heated with not more than one piece of cookware heated at a time; the area of the cooking zone may be visibly marked on the surface of the hob; (19) "cooking area" means a part of an area of an electric hob heated by an inducted magnetic field, where cookware is placed for heating without visible marking for the cookware and where more than one item of cookware can be used simultaneously; (20) "range hood" means an appliance, operated by a motor which it controls, intended to collect contaminated air from above a hob, or which includes a downdraft system intended for installation adjacent to cooking ranges, hobs and similar cooking products, that draws vapour down into an internal exhaust duct; (21) "automatic functioning mode during the cooking period" means a condition in which the air flow of the range hood during the cooking period is automatically controlled through sensor(s), including as regards humidity, temperature, etc.; (22) "fully automatic range hood" means a range hood in which the air flow and/or other functions are automatically controlled through sensor(s) during 24 hours including the cooking period; (23) "best efficiency point" (BEP) means the range hood operating point with maximum fluid dynamic efficiency (FDE hood );(24) "average illumination" (E middle ) means the average illumination provided by the lighting system of the range hood on the cooking surface, measured in lux;(25) "off mode" means a condition in which the equipment is connected to the mains power source but is not providing any function, or only provides an indication of off-mode condition, or only provides functionalities intended to ensure electromagnetic compatibility pursuant to Directive 2004/108/EC of the European Parliament and of the Council ;Directive 2004/108/EC of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC (OJ L 390, 31.12.2004, p. 24 ).(26) "standby mode" means a condition where the equipment is connected to the mains power source, depends on energy input from the mains power source to work as intended and provides only reactivation function, or reactivation function and only an indication of enabled reactivation function, and/or information or status display, which may persist for an indefinite time; (27) "reactivation function" means a function facilitating the activation of other modes, including the active mode, by remote switch including remote control, internal sensor, or timer to a condition providing additional functions, including the main function; (28) "information or status display" means a continuous function providing information or indicating the status of the equipment on a display, including clocks; (29) "end-user" means a consumer buying or expected to buy a product; (30) "equivalent model" means a model placed on the market with the same technical parameters as another model placed on the market under a different commercial code number by the same manufacturer or importer.
Domestic electric & gas oven | |
---|---|
From 1 year after the entry into force | EEI |
From 2 years after the entry into force | EEI |
From 5 years after the entry into force | EEI |
From 1 year after the entry into force | EC | EE |
---|---|---|
From 3 years after the entry into force | EC | EE |
From 5 years after the entry into force | EC | EE |
EEI | FDE | |
---|---|---|
From 1 year after the entry into force | EEI | FDE |
From 3 years after the entry into force | EEI | FDE |
From 5 years after the entry into force | EEI | FDE |
Power consumption in "off mode": the power consumption in any off-mode condition shall not exceed 1,00 W. Power consumption in "standby mode(s)": The power consumption in any condition providing only a reactivation function, or providing only a reactivation function and a mere indication of enabled reactivation function, shall not exceed 1,00 W. The power consumption of equipment in any condition providing only information or status display, or providing only a combination of reactivation function and information or status display, shall not exceed 2,00 W.
Availability of "off mode" and/or "standby mode": domestic range hoods shall provide "off mode" and/or "standby mode", and/or another condition which does not exceed the applicable power consumption requirements for "off mode" and/or "standby mode" when the equipment is connected to the mains power source.
Power consumption in "off mode": the power consumption in any off-mode condition shall not exceed 0,50 W. Power consumption in "standby mode(s)": the power consumption in any condition providing only a reactivation function, or providing only a reactivation function and a mere indication of enabled reactivation function, shall not exceed 0,50 W. The power consumption of equipment in any condition providing only information or status display, or providing only a combination of reactivation function and information or status display shall not exceed 1,00 W. Power management: when domestic range hoods are not providing the main function, or when other energy-using product(s) are not dependent on its functions, equipment shall, unless inappropriate for the intended use, offer a power management function, or a similar function, that switches equipment after the shortest possible period of time appropriate for the intended use of the equipment, automatically into: "standby mode", or "off mode", or another condition which does not exceed the applicable power consumption requirements for "off mode" and/or "standby mode" when the equipment is connected to the mains power source.
The power management function shall be activated before delivery. For range hoods with automatic functioning mode during the cooking period and fully automatic range hoods, the delay time after which the product switches automatically into the modes and conditions as referred to in the previous point shall be one minute after the motor and lighting have both been switched off either automatically or manually.
(a) short title or reference to the measurement and calculation methods used to establish compliance with the above requirements; (b) information relevant to users in order to reduce total environmental impact (e.g. energy use) of the cooking process.
Symbol | Value | Unit | |
---|---|---|---|
Model identification | |||
Type of oven | |||
Mass of the appliance | M | X,X | kg |
Number of cavities | X | ||
Heat source per cavity (electricity or gas) | |||
Volume per cavity | V | X | l |
Energy consumption (electricity) required to heat a standardised load in a cavity of an electric heated oven during a cycle in conventional mode per cavity (electric final energy) | EC | X,XX | kWh/cycle |
Energy consumption required to heat a standardised load in a cavity of an electric heated oven during a cycle in fan-forced mode per cavity (electric final energy) | EC | X,XX | kWh/cycle |
Energy consumption required to heat a standardised load in a gas-fired cavity of an oven during a cycle in conventional mode per cavity (gas final energy) | EC | ||
Energy consumption required to heat a standardised load in a gas-fired cavity of an oven during a cycle in fan-forced mode per cavity (gas final energy) | EC | ||
Energy Efficiency Index per cavity | EEI | X,X |
Symbol | Value | Unit | |
---|---|---|---|
Model identification | |||
Type of hob | |||
Number of cooking zones and/or areas | X | ||
Heating technology (induction cooking zones and cooking areas, radiant cooking zones, solid plates) | |||
For circular cooking zones or area: diameter of useful surface area per electric heated cooking zone, rounded to the nearest 5 mm | Ø | X,X | cm |
For non-circular cooking zones or areas: length and width of useful surface area per electric heated cooking zone or area, rounded to the nearest 5 mm | cm | ||
Energy consumption per cooking zone or area calculated per kg | EC | X,X | Wh/kg |
Energy consumption for the hob calculated per kg | EC | X,X | Wh/kg |
Symbol | Value | Unit | |
---|---|---|---|
Model identification | |||
Type of hob | |||
Number of gas burners | X | ||
Energy efficiency per gas burner | EE | X,X | |
Energy efficiency for the gas hob | EE | X,X |
Symbol | Value | Unit | |
---|---|---|---|
Model identification | |||
Type of hob | |||
Number of electric cooking zones and/or areas | X | ||
Heating technology (induction cooking zones and cooking areas, radiant cooking zones, solid plates) per electric cooking zone and/or area | |||
For circular electric cooking zones: diameter of useful surface area per electric heated cooking zone, rounded to the nearest 5 mm | Ø | X,X | cm |
For non-circular electric cooking zones or areas: length and width of useful surface area per electric heated cooking zone or area, rounded to the nearest 5 mm | cm | ||
Energy consumption per electric cooking zone or area calculated per kg | EC | X | Wh/kg |
Number of gas fired burners | X | ||
Energy efficiency per gas burner | EE | X,X |
Symbol | Value | Unit | |
---|---|---|---|
Model identification | |||
Annual Energy Consumption | AEC | X,X | kWh/a |
Time increase factor | f | X,X | |
Fluid Dynamic Efficiency | FDE | X,X | |
Energy Efficiency Index | EEI | X,X | |
Measured air flow rate at best efficiency point | Q | X,X | m |
Measured air pressure at best efficiency point | P | X | Pa |
Maximum air flow | Q | X,X | m |
Measured electric power input at best efficiency point | W | X,X | W |
Nominal power of the lighting system | W | X,X | W |
Average illumination of the lighting system on the cooking surface | E | X | lux |
Measured power consumption in standby mode | P | X,XX | W |
Measured power consumption off mode | P | X,XX | W |
Sound power level | L | X | dB |
W is the electric power input of the domestic range hood at the best efficiency point, in Watt and rounded to the first decimal place,BEP W is the nominal electric power input of the lighting system of the domestic range hood on the cooking surface, in Watt and rounded to the first decimal place.L
(i) for the fully automatic domestic range hoods: (ii) for all other domestic range hoods: Where: t is the average lighting time per day, in minutes (tL L = 120),t is the average running time per day for domestic range hoods, in minutes (tH H = 60),P is the electric power input in off mode of the domestic range hood, in Watt and rounded to the second decimal place,o P is the electric power input in standby mode of the domestic range hood, in Watt and rounded to the second decimal place,s f is the time increase factor, calculated and rounded to the first decimal place, as:
Q is the flow rate of the domestic range hood at best efficiency point, expressed in mBEP 3 /h and rounded to the first decimal place,P is the static pressure difference of the domestic range hood at best efficiency point, expressed in Pa and rounded to the nearest integer,BEP W is the electric power input of the domestic range hood at the best efficiency point, expressed in Watt and rounded to the first decimal place.BEP
V max is the maximum volume of air to be extracted, set at 100 m3 ,Q max is the maximum air flow of the range hood, including intensive/boost mode if present,t is the time expressed in minutes and rounded to the nearest integer,dt is the total time until the air volume of 100 m3 has been reached,t is the time limit, expressed in minutes and rounded to the nearest integer, needed to extract 100 mlimit 3 .
Q max is the maximum air flow of the domestic range hood, including intensive/boost mode if present, in m3 /h and rounded to the first decimal place.
the activation of the automatic functioning mode shall be possible only through a manual operation by the user, either on the hood or elsewhere, the automatic functioning mode shall revert to manual control after no more than 10 minutes from the moment the automatic function switches off the motor.
(1) The Member State authorities shall verify one single unit of the model. (2) The model shall be considered to comply with the applicable requirements if: (a) the values given in the technical documentation pursuant to point 2 of Annex IV to Directive 2009/125/EC (declared values), and, where applicable, the values used to calculate these values, are not more favourable for the manufacturer or importer than the results of the corresponding measurements carried out pursuant to paragraph (g) thereof; and (b) the declared values meet any requirements laid down in this Regulation, and any required product information published by the manufacturer or importer does not contain values that are more favourable for the manufacturer or importer than the declared values; and (c) when the Member State authorities test the unit of the model, the determined values (the values of the relevant parameters as measured in testing and the values calculated from these measurements) comply with the respective verification tolerances as given in Table 7.
(3) If the results referred to in point 2(a) or (b) are not achieved, the model and all models that have been listed as equivalent models in the manufacturer's or importer's technical documentation shall be considered not to comply with this Regulation. (4) If the result referred to in point 2(c) is not achieved, the Member State authorities shall select three additional units of the same model for testing. As an alternative, the three additional units selected may be of one or more different models that have been listed as equivalent models in the manufacturer's or importer's technical documentation. (5) The model shall be considered to comply with the applicable requirements if, for these three units, the arithmetical mean of the determined values complies with the respective verification tolerances given in Table 7. (6) If the result referred to in point 5 is not achieved, the model and all models that have been listed as equivalent models in the manufacturer's or importer's technical documentation shall be considered not to comply with this Regulation. (7) The Member State authorities shall provide all relevant information to the authorities of the other Member States and to the Commission without delay after a decision being taken on the non-compliance of the model according to points 3 and 6.
Parameters | Verification tolerances |
---|---|
Mass of the domestic oven, | The determined value shall not exceed the declared value of |
Volume of the cavity of the domestic oven, | The determined value shall not be lower than the declared value of |
The determined values shall not exceed the declared values of | |
The determined value shall not exceed the declared value of | |
The determined value shall not be lower than the declared value of | |
The determined values shall not exceed the declared values of | |
The determined values shall not be lower than the declared values of | |
The determined value shall not exceed the declared value of | |
The determined value shall not be lower than the declared value of | |
Sound power level, | The determined value shall not exceed the declared value of |
The determined values of power consumption |
Domestic ovens | Electric | EEI |
---|---|---|
Gas | EEI | |
Domestic hobs | Electric | EC |
Gas | EE | |
Domestic range hoods | Air flow | FDE |
Noise | 51 dB at 550 m |
(a) appliances that use energy sources other than electricity or gas; (b) appliances which offer "microwave heating" function; (c) small ovens; (d) portable ovens; (e) heat storage ovens; (f) ovens which are heated with steam as a primary heating function; (g) covered gas burners in hobs; (h) outdoor cooking appliances; (i) appliances designed for use only with gases of the "third family" (propane and butane); (j) grills.
(1) "oven" means an appliance or part of an appliance which incorporates one or more cavities using electricity and/or gas in which food is prepared by use of a conventional or fan-forced mode; (2) "cavity" means the enclosed compartment in which the temperature can be controlled for preparation of food; (3) "multi-cavity oven" means an oven with two or more cavities, each of which is heated separately; (4) "small oven" means an oven where all cavities have a width and depth of less than 250 mm or a height less than 120 mm; (5) "portable oven" means an oven with a product mass of less than 18 kilograms, provided it is not designed for built-in installations; (6) "microwave heating" means heating of food using electromagnetic energy; (7) "conventional mode" means the operation mode of an oven only using natural convection for circulation of heated air inside the cavity of the oven; (8) "fan-forced mode" means a mode when a built-in fan circulates heated air inside the cavity of the oven; (9) "cycle" means the period of heating a standardised load in a cavity of an oven under defined conditions; (10) "cooker" means an appliance consisting of an oven and a hob using gas or electricity; (11) "operation mode" means the status of the oven or hob during use; (12) "heat source" means the main energy form for heating an oven or hob; (13) "electric hob" means an appliance or part of an appliance which incorporates one or more cooking zones and/or cooking areas including a control unit and which is heated by electricity; (14) "gas hob" means an appliance or part of an appliance which incorporates one or more cooking zones including a control unit and which is heated by gas burners of a minimum power of 1,16 kW; (15) "hob" means an "electric hob", a "gas hob" or a "mixed hob"; (16) "covered gas burners" means closed or sealed gas range burners covered with a heavy-duty glass or ceramic cover, which forms a smooth, seamless cooking surface; (17) "mixed hob" means an appliance with one or more electrically heated cooking zones or areas and one or more cooking zones heated by gas burners; (18) "cooking zone" means a part, with a diameter of at least 100 mm, of a hob where cookware is placed and heated with not more than one piece of cookware heated at a time; the area of the cooking zone may be visibly marked on the surface of the hob; (19) "cooking area" means a part of an area of an electric hob heated by an inducted magnetic field, where cookware is placed for heating without visible marking for the cookware and where more than one item of cookware can be used simultaneously; (20) "range hood" means an appliance, operated by a motor which it controls, intended to collect contaminated air from above a hob, or which includes a downdraft system intended for installation adjacent to cooking ranges, hobs and similar cooking products, that draws vapour down into an internal exhaust duct; (21) "automatic functioning mode during the cooking period" means a condition in which the air flow of the range hood during the cooking period is automatically controlled through sensor(s), including as regards humidity, temperature, etc.; (22) "fully automatic range hood" means a range hood in which the air flow and/or other functions are automatically controlled through sensor(s) during 24 hours including the cooking period; (23) "best efficiency point" (BEP) means the range hood operating point with maximum fluid dynamic efficiency (FDE hood );(24) "average illumination" (E middle ) means the average illumination provided by the lighting system of the range hood on the cooking surface, measured in lux;(25) "off mode" means a condition in which the equipment is connected to the mains power source but is not providing any function, or only provides an indication of off-mode condition, or only provides functionalities intended to ensure electromagnetic compatibility pursuant to Directive 2004/108/EC of the European Parliament and of the Council ;Directive 2004/108/EC of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC (OJ L 390, 31.12.2004, p. 24 ).(26) "standby mode" means a condition where the equipment is connected to the mains power source, depends on energy input from the mains power source to work as intended and provides only reactivation function, or reactivation function and only an indication of enabled reactivation function, and/or information or status display, which may persist for an indefinite time; (27) "reactivation function" means a function facilitating the activation of other modes, including the active mode, by remote switch including remote control, internal sensor, or timer to a condition providing additional functions, including the main function; (28) "information or status display" means a continuous function providing information or indicating the status of the equipment on a display, including clocks; (29) "end-user" means a consumer buying or expected to buy a product; (30) "equivalent model" means a model placed on the market with the same technical parameters as another model placed on the market under a different commercial code number by the same manufacturer or importer.
Domestic electric & gas oven | |
---|---|
From 1 year after the entry into force | EEI |
From 2 years after the entry into force | EEI |
From 5 years after the entry into force | EEI |
From 1 year after the entry into force | EC | EE |
---|---|---|
From 3 years after the entry into force | EC | EE |
From 5 years after the entry into force | EC | EE |
EEI | FDE | |
---|---|---|
From 1 year after the entry into force | EEI | FDE |
From 3 years after the entry into force | EEI | FDE |
From 5 years after the entry into force | EEI | FDE |
Power consumption in "off mode": the power consumption in any off-mode condition shall not exceed 1,00 W. Power consumption in "standby mode(s)": The power consumption in any condition providing only a reactivation function, or providing only a reactivation function and a mere indication of enabled reactivation function, shall not exceed 1,00 W. The power consumption of equipment in any condition providing only information or status display, or providing only a combination of reactivation function and information or status display, shall not exceed 2,00 W.
Availability of "off mode" and/or "standby mode": domestic range hoods shall provide "off mode" and/or "standby mode", and/or another condition which does not exceed the applicable power consumption requirements for "off mode" and/or "standby mode" when the equipment is connected to the mains power source.
Power consumption in "off mode": the power consumption in any off-mode condition shall not exceed 0,50 W. Power consumption in "standby mode(s)": the power consumption in any condition providing only a reactivation function, or providing only a reactivation function and a mere indication of enabled reactivation function, shall not exceed 0,50 W. The power consumption of equipment in any condition providing only information or status display, or providing only a combination of reactivation function and information or status display shall not exceed 1,00 W. Power management: when domestic range hoods are not providing the main function, or when other energy-using product(s) are not dependent on its functions, equipment shall, unless inappropriate for the intended use, offer a power management function, or a similar function, that switches equipment after the shortest possible period of time appropriate for the intended use of the equipment, automatically into: "standby mode", or "off mode", or another condition which does not exceed the applicable power consumption requirements for "off mode" and/or "standby mode" when the equipment is connected to the mains power source.
The power management function shall be activated before delivery. For range hoods with automatic functioning mode during the cooking period and fully automatic range hoods, the delay time after which the product switches automatically into the modes and conditions as referred to in the previous point shall be one minute after the motor and lighting have both been switched off either automatically or manually.
(a) short title or reference to the measurement and calculation methods used to establish compliance with the above requirements; (b) information relevant to users in order to reduce total environmental impact (e.g. energy use) of the cooking process.
Symbol | Value | Unit | |
---|---|---|---|
Model identification | |||
Type of oven | |||
Mass of the appliance | M | X,X | kg |
Number of cavities | X | ||
Heat source per cavity (electricity or gas) | |||
Volume per cavity | V | X | l |
Energy consumption (electricity) required to heat a standardised load in a cavity of an electric heated oven during a cycle in conventional mode per cavity (electric final energy) | EC | X,XX | kWh/cycle |
Energy consumption required to heat a standardised load in a cavity of an electric heated oven during a cycle in fan-forced mode per cavity (electric final energy) | EC | X,XX | kWh/cycle |
Energy consumption required to heat a standardised load in a gas-fired cavity of an oven during a cycle in conventional mode per cavity (gas final energy) | EC | ||
Energy consumption required to heat a standardised load in a gas-fired cavity of an oven during a cycle in fan-forced mode per cavity (gas final energy) | EC | ||
Energy Efficiency Index per cavity | EEI | X,X |
Symbol | Value | Unit | |
---|---|---|---|
Model identification | |||
Type of hob | |||
Number of cooking zones and/or areas | X | ||
Heating technology (induction cooking zones and cooking areas, radiant cooking zones, solid plates) | |||
For circular cooking zones or area: diameter of useful surface area per electric heated cooking zone, rounded to the nearest 5 mm | Ø | X,X | cm |
For non-circular cooking zones or areas: length and width of useful surface area per electric heated cooking zone or area, rounded to the nearest 5 mm | cm | ||
Energy consumption per cooking zone or area calculated per kg | EC | X,X | Wh/kg |
Energy consumption for the hob calculated per kg | EC | X,X | Wh/kg |
Symbol | Value | Unit | |
---|---|---|---|
Model identification | |||
Type of hob | |||
Number of gas burners | X | ||
Energy efficiency per gas burner | EE | X,X | |
Energy efficiency for the gas hob | EE | X,X |
Symbol | Value | Unit | |
---|---|---|---|
Model identification | |||
Type of hob | |||
Number of electric cooking zones and/or areas | X | ||
Heating technology (induction cooking zones and cooking areas, radiant cooking zones, solid plates) per electric cooking zone and/or area | |||
For circular electric cooking zones: diameter of useful surface area per electric heated cooking zone, rounded to the nearest 5 mm | Ø | X,X | cm |
For non-circular electric cooking zones or areas: length and width of useful surface area per electric heated cooking zone or area, rounded to the nearest 5 mm | cm | ||
Energy consumption per electric cooking zone or area calculated per kg | EC | X | Wh/kg |
Number of gas fired burners | X | ||
Energy efficiency per gas burner | EE | X,X |
Symbol | Value | Unit | |
---|---|---|---|
Model identification | |||
Annual Energy Consumption | AEC | X,X | kWh/a |
Time increase factor | f | X,X | |
Fluid Dynamic Efficiency | FDE | X,X | |
Energy Efficiency Index | EEI | X,X | |
Measured air flow rate at best efficiency point | Q | X,X | m |
Measured air pressure at best efficiency point | P | X | Pa |
Maximum air flow | Q | X,X | m |
Measured electric power input at best efficiency point | W | X,X | W |
Nominal power of the lighting system | W | X,X | W |
Average illumination of the lighting system on the cooking surface | E | X | lux |
Measured power consumption in standby mode | P | X,XX | W |
Measured power consumption off mode | P | X,XX | W |
Sound power level | L | X | dB |
W is the electric power input of the domestic range hood at the best efficiency point, in Watt and rounded to the first decimal place,BEP W is the nominal electric power input of the lighting system of the domestic range hood on the cooking surface, in Watt and rounded to the first decimal place.L
(i) for the fully automatic domestic range hoods: (ii) for all other domestic range hoods: Where: t is the average lighting time per day, in minutes (tL L = 120),t is the average running time per day for domestic range hoods, in minutes (tH H = 60),P is the electric power input in off mode of the domestic range hood, in Watt and rounded to the second decimal place,o P is the electric power input in standby mode of the domestic range hood, in Watt and rounded to the second decimal place,s f is the time increase factor, calculated and rounded to the first decimal place, as:
Q is the flow rate of the domestic range hood at best efficiency point, expressed in mBEP 3 /h and rounded to the first decimal place,P is the static pressure difference of the domestic range hood at best efficiency point, expressed in Pa and rounded to the nearest integer,BEP W is the electric power input of the domestic range hood at the best efficiency point, expressed in Watt and rounded to the first decimal place.BEP
V max is the maximum volume of air to be extracted, set at 100 m3 ,Q max is the maximum air flow of the range hood, including intensive/boost mode if present,t is the time expressed in minutes and rounded to the nearest integer,dt is the total time until the air volume of 100 m3 has been reached,t is the time limit, expressed in minutes and rounded to the nearest integer, needed to extract 100 mlimit 3 .
Q max is the maximum air flow of the domestic range hood, including intensive/boost mode if present, in m3 /h and rounded to the first decimal place.
the activation of the automatic functioning mode shall be possible only through a manual operation by the user, either on the hood or elsewhere, the automatic functioning mode shall revert to manual control after no more than 10 minutes from the moment the automatic function switches off the motor.
(1) The Member State authorities shall verify one single unit of the model. (2) The model shall be considered to comply with the applicable requirements if: (a) the values given in the technical documentation pursuant to point 2 of Annex IV to Directive 2009/125/EC (declared values), and, where applicable, the values used to calculate these values, are not more favourable for the manufacturer or importer than the results of the corresponding measurements carried out pursuant to paragraph (g) thereof; and (b) the declared values meet any requirements laid down in this Regulation, and any required product information published by the manufacturer or importer does not contain values that are more favourable for the manufacturer or importer than the declared values; and (c) when the Member State authorities test the unit of the model, the determined values (the values of the relevant parameters as measured in testing and the values calculated from these measurements) comply with the respective verification tolerances as given in Table 7.
(3) If the results referred to in point 2(a) or (b) are not achieved, the model and all models that have been listed as equivalent models in the manufacturer's or importer's technical documentation shall be considered not to comply with this Regulation. (4) If the result referred to in point 2(c) is not achieved, the Member State authorities shall select three additional units of the same model for testing. As an alternative, the three additional units selected may be of one or more different models that have been listed as equivalent models in the manufacturer's or importer's technical documentation. (5) The model shall be considered to comply with the applicable requirements if, for these three units, the arithmetical mean of the determined values complies with the respective verification tolerances given in Table 7. (6) If the result referred to in point 5 is not achieved, the model and all models that have been listed as equivalent models in the manufacturer's or importer's technical documentation shall be considered not to comply with this Regulation. (7) The Member State authorities shall provide all relevant information to the authorities of the other Member States and to the Commission without delay after a decision being taken on the non-compliance of the model according to points 3 and 6.
Parameters | Verification tolerances |
---|---|
Mass of the domestic oven, | The determined value shall not exceed the declared value of |
Volume of the cavity of the domestic oven, | The determined value shall not be lower than the declared value of |
The determined values shall not exceed the declared values of | |
The determined value shall not exceed the declared value of | |
The determined value shall not be lower than the declared value of | |
The determined values shall not exceed the declared values of | |
The determined values shall not be lower than the declared values of | |
The determined value shall not exceed the declared value of | |
The determined value shall not be lower than the declared value of | |
Sound power level, | The determined value shall not exceed the declared value of |
The determined values of power consumption |
Domestic ovens | Electric | EEI |
---|---|---|
Gas | EEI | |
Domestic hobs | Electric | EC |
Gas | EE | |
Domestic range hoods | Air flow | FDE |
Noise | 51 dB at 550 m |