Commission Directive 2004/73/EC of 29 April 2004 adapting to technical progress for the twenty-ninth time Council Directive 67/548/EEC on the approximation of the laws, regulations and administrative provisions relating to the classification, packaging and labelling of dangerous substances (Text with EEA relevance)
Corrected by
ANNEX 4EXAMPLE CALCULATION FOR APPLICATION DOSE TO TEST VESSELS
Cylinder internal diameter:= 8 cm
Water column depth not including sediment:= 12 cm
Surface area: 3,142 × 42= 50,3 cm2
Application rate: 500 g test substance/ha corresponds to 5 μg/cm2
Total μg: 5 × 50,3= 251,5 μg
Adjust quantity in relation to a depth of 100 cm: 12 × 251,5 ÷ 100= 30,18 μg
Volume of water column: 50,3 × 12= 603 ml