Directive 96/57/EC of the European Parliament and of the Council of 3 September 1996 on energy efficiency requirements for household electric refrigerators, freezers and combinations thereof
Modified by
- Directive 2005/32/EC of the European Parliament and of the Councilof 6 July 2005establishing a framework for the setting of ecodesign requirements for energy-using products and amending Council Directive 92/42/EEC and Directives 96/57/EC and 2000/55/EC of the European Parliament and of the Council, 32005L0032, July 22, 2005
- Directive 2008/28/EC of the European Parliament and of the Councilof 11 March 2008amending Directive 2005/32/EC establishing a framework for the setting of ecodesign requirements for energy-using products, as well as Council Directive 92/42/EEC and Directives 96/57/EC and 2000/55/EC, as regards the implementing powers conferred on the Commission, 32008L0028, March 20, 2008
- Commission Regulation (EC) No 643/2009of 22 July 2009implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for household refrigerating appliances(Text with EEA relevance), 32009R0643, July 23, 2009
(a) Where refrigeration appliances are subject to other directives covering other aspects which also provide for affixing of the "CE" marking, the latter shall indicate that the refrigeration appliances in question are also presumed, unless evidence to the contrary exists, to conform to the provisions of those other directives. (b) However, where one or more of those directives allows the manufacturer, during a transitional period, to choose which rules to apply, the "CE" marking shall indicate conformity solely with the provisions of those directives applied by the manufacturer. In that case, the reference numbers of the directives applied, as published in the Official Journal of the European Communities , must be given in the documents, notices or instructions accompanying the refrigeration appliances.
1 | Refrigerator, without low temperature compartment |
2 | Refrigerator/chiller, with compartment at 5 °C and/or 12 °C |
3 | Refrigerator, with no-star low temperature compartment |
4 | Refrigerator, with low temperature compartment (*) |
5 | Refrigerator, with low temperature compartment (**) |
6 | Refrigerator, with low temperature compartment (***) |
7 | Refrigerator/freezer, with freezer compartment (****) |
8 | Food freezer, upright |
9 | Food freezer, chest |
10 | Refrigerator/freezer with more than two doors, or other appliances not covered above. |
C | for refrigeration appliances belonging to the normal (N) and subnormal (SN) climate classes |
C | for refrigeration appliances belonging to the sub-tropical (ST) climate class |
C | for refrigeration appliances belonging to the tropical (T) climate class. |
X | Y | |
---|---|---|
Cellar compartment | ||
Fresh food compartment | ||
0 °C compartment | ||
No-star compartment | ||
1-star (*) compartment | ||
2-star (**) compartment | ||
3 (***) and 4-star (****) compartments |
1 | Refrigerator, without low temperature compartment | (0,207 × V |
2 | Refrigerator/chiller, with compartment at 5 °C and/or 12 °C | (0,207 × V |
3 | Refrigerator, with no-star low temperature compartment | (0,207 × V |
4 | Refrigerator, with low temperature compartment (*) | (0,557 × V |
5 | Refrigerator, with low temperature compartment (**) | (0,402 × V |
6 | Refrigerator, with low temperature compartment (***) | (0,573 × V |
7 | Refrigerator/freezer, with freezer compartment (****) | (0,697 × V |
8 | Food freezer, upright | (0,434 × V |
9 | Food freezer, chest | (0,480 × V |
> - 6 °C | 1/2/3 | (0,207 × V |
≤ - 6 °C (*) | 4 | (0,557 × V |
≤ - 12 °C (**) | 5 | (0,402 × V |
≤ - 18 °C (***) | 6 | (0,573 × V |
≤ - 18 °C (****) | 7 | (0,697 × V |
(i) the name and the address of the manufacturer; (ii) a general description of the model sufficient for unambiguous identification; (iii) information, including drawings as relevant, on the main design features of the model and in particular on items which appreciably affect its electricity consumption, such as dimensions, volume(s), compressor characteristics, special features, etc.; (iv) the operating instructions, if any; (v) the results of electricity consumption measurements carried out as required by point 5; (vi) details of the conformity of these measurements as compared to the energy consumption requirements set out in Annex I.