identification and determination of glycerol l-(4-aminobenzoate), determination of chlorobutanol, identification and determination of quinine, identification and determination of inorganic sulphites and hydrogen sulphites, identification and determination of chlorates of the alkali metals, and identification and determination of sodium iodate are performed in accordance with the methods described in the Annex.
Fourth Commission Directive 85/490/EEC of 11 October 1985 on the approximation of the laws of the Member States relating to methods of analysis necessary for checking the composition of cosmetic products
(a) sodium nitrite: 1 g in 100 ml of 1 M hydrochloric acid (prepared immediately before use); (b) 2-naphthol: 0,2 g in 100 ml of 1 M potassium hydroxide.
alpha-monoglyceryl 4-aminobenzoate: 0,05 g in 100 ml of mixed solvent 3.1; ethyl 4-aminobenzoate: 0,05 g in 100 ml of mixed solvent 3.1.
Standard Solution | Alpha-monoglyceryl 4-aminobenzoate | Ethyl 4-aminobenzoate | Ethyl 4-hydroxybenzoate | |||
---|---|---|---|---|---|---|
(μg/ml) | ml (4.11) | (μg/ml) | ml (4.12) | (μg/ml) | ml (4.13) | |
I | 8 | 2 | 8 | 2 | 50 | 10 |
II | 16 | 4 | 12 | 3 | 50 | 10 |
III | 24 | 6 | 16 | 4 | 50 | 10 |
IV | 40 | 10 | 20 | 5 | 50 | 10 |
Column | I | II |
---|---|---|
Material | Glass | Stainless steel |
Length | 1,80 m | 3 m |
Diameter | 3 mm | 3 mm |
Stationary phase | 10 % Carbowax 20 M TPA on Gaschrom Q 80-100 mesh | 5 % OV 17 on Chromosorb WAW DMCS 80-100 mesh |
Conditioning | 2 to 3 days at 190 | |
Temperature: | ||
— injector | 200 | 150 |
— column | 150 | 100 |
— detector | 200 | 150 |
Carrier gas | Nitrogen | Argon/methane (95/5 v/v) |
Flowrate | 35 ml/min | 35 ml/min |
Alkaloid | R |
---|---|
Quinine | 0,20 |
Quinidine | 0,29 |
Cinchonine | 0,33 |
Cinchonidine | 0,27 |
Hydroquinidine | 0,17 |
Flowrate: 1,0 ml/min. Detector wavelength (5.3): 332 nm. Injection volume: 10 μl of filtered solution (6.1). Measurement: peak area.
Halates | R |
---|---|
Iodate | 0 to 0,2 |
Bromate | 0,5 to 0,6 |
Chlorate | 0,7 to 0,8 |