determination of dichloromethane and 1,1,1-trichloroethane, identification and determination of quinolin-8-ol and bis(8-hydroxyquinolinium) sulphate, determination of ammonia, identification and determination of nitro-methane, identification and determination of mercapto-acetic acid in hair-waving, hair-straightening and depilatory products, identification and determination of hexachlorophene (INN), determination of tosylchloramide sodium (INN), determination of total fluorine in dental creams, identification and determination of organo-mercury compounds, determination of alkali and alkaline earth sulphides,
Third Commission Directive 83/514/EEC of 27 September 1983 on the approximation of the laws of the Member States relating to methods of analysis necessary for checking the composition of cosmetic products
6.2.1. After transferring a sample into a transfer bottle (5.3), further introduce into the transfer bottle a volume of chloroform (4.1) as internal standard equivalent to the presumed quantity of dichloromethane and/or 1,1,1-trichloroethane contained in the sample. Mix thoroughly. Rinse the dead volume of the valve with 0,5 ml of carbon tetrachloride (4.2). After drying, determine accurately the added mass of the internal standard by difference. 6.2.2. After filling the syringe with the sample, the nozzle of the syringe should be purged with nitrogen (4.6) so that no residue remains before injection into the chromatograph. 6.2.3. After each sample is taken, the surface of the valve and of the transfer piece should be rinsed several times with acetone (4.5) (using as required a hypodermic syringe) and then dried thoroughly with nitrogen (4.6). 6.2.4. For each analysis, take measurements using two different transfer bottles and five measurements per bottle.
Material: | Stainless steel tubing | Stainless steel tubing |
Length: | 350 cm | 400 cm |
Diameter: | 3 mm | 6 mm |
Support: | ||
chromosorb: | WAW | WAW-DMCS-HP |
sieve analysis | 100 to 120 mesh | 60 to 80 mesh |
Stationary phase: | Hallcomid M 18, 10% | Hallcomid M 18, 20% |
Temperatures: | ||
column: | 65 | 75 |
injector: | 150 | 125 |
detector: | 150 | 200 |
Carrier gas: | ||
helium flow rate: | 45 ml/min | 60 ml/min |
inlet pressure | 2,5 bar | 2 bar |
Injection: | 15 μl | 15μl |
the state of activation of the thin layer at the time of chromatographing, the temperature of the chromatography tank.
Eluting solvents | ||
---|---|---|
4.2.1.16.1 | 4.2.1.16.2 | |
Mercaptoacetic acid | 0,25 | 0,80 |
2-mercaptopropionic acid | 0,40 | 0,95 |
2,2'-dithiodi(acetic) acid | 0,00 | 0,35 |
3-mercaptopropionic acid | 0,45 | 0,95 |
3-mercaptopropane-1,2 diol | 0,45 | 0,35 |
2 ml of methyl octanoate solution (5.2.2.5), 5 ml of hydrochloric acid in methanol (5.2.2.7).
Rf | Colour | |
---|---|---|
Thiomersal | 0,33 | Orange |
Ethylmercury chloride | 0,29 | Orange |
Methylmercury chloride | 0,29 | Orange |
Phenylmercury salts | 0,21 | Orange |
Mercury (II) salts | 0,10 | Orange |
Mercury di(acetate) | 0,10 | Orange |
1,5-diphenyl-3-thiocarbazone | 0,09 | Pink |